Skip to content

ECB violations

Ps 173, Manhattan • Block 02142 • Lot 0154

139 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
May 18, 2009 34791934Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER - STAIRWAY G REMOVE DESKS & CHAIRS AT FLRS 2 & 3. REMEDY: MAINT... $0 $0 Aug 13, 2009
May 18, 2009 34791938X RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER - BOILER RM - MAIN ENTRANCE - EXIT LIGHT PENETRATION NOT FIRE S... $0 $0 Aug 13, 2009
May 18, 2009 34791936M ACTIVE CLASS - 2 ALTERED/CHANGED BUILDING OCCUPIED W/O A VALID C OF O. TEMP C.O. 121773EXPIRED 8/7/01. REMEDY: OBTAIN VALID C OF O AND... $0 $0 Aug 13, 2009
Sep 10, 2007 34589932X RESOLVE Hazardous REISSUE# 34445602K. EXIT PASSAGEWAY/CORRIDOR IS OBSTRUCTED W/ SCHOOL FURNITURE (TABLES & CHAIRS) LOCATED PM CELLAR LE... $0 $0 Nov 15, 2007
Sep 10, 2007 34589931Y RESOLVE Hazardous REISSUE# 34445698Y (PARTIAL). INTERIOR PLASTER IS SPALLING ON THE WALLS LOCATED AT THE ELEVATOR LOBBY ON THE 4TH FL L... $0 $0 Nov 15, 2007
May 17, 2006 34445602K RESOLVE Hazardous EXIT PASSAGE OR CORRIDOR:REQUIRED WIDTH DECREASED BY OBSTRUCTION.NOTEDCELLAR STAIRWAY LEADS TO CELLAR LEVEL LOBBY FIL... $0 $0 Aug 17, 2006
May 17, 2006 34445601Z RESOLVE Hazardous FAILURE TO MAINTAIN BLDG INTERIOR.NOTED:NO DOOR CHECKS AT FOLLOWING RMS.517,518,520,506,414,407.DEFECTIVE DOOR CHECKS... $0 $0 Aug 17, 2006
May 17, 2006 34445603M RESOLVE Hazardous USE OF ILLEGAL HARDWARE.NOTED:S/E EXIT DOORS W/ PADLOCK ON 1 DOOR(LOCKED OPEN).AT S/SIDE OF GYM,1 OF THE 2 SETS OF DO... $0 $0 Aug 17, 2006
May 17, 2006 34445698Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING. INTERIOR. NOTED: VERTICAL CRACKS IN PLASTER ADJACENT TO ELEVATOR LOBBIES ON FLOORS 2,3,... $0 $0 Aug 17, 2006
May 17, 2006 34445699X RESOLVE Non-Hazardous FAILURE TO PROVIDE/MAINTAIN FIRES STOPPING WHERE REQUIRED.NOTED:CELLARCONSTRUCTION WORK IN PROGRESS FOR OVER 1 YEAR C... $0 $0 Aug 17, 2006
Dec 15, 2005 38164128R RESOLVE Non-Hazardous 85M07/38O02 (85-M-05) 5 YR TAG MISSING, PERFORM AND FILE TEST. $0 $0 Mar 16, 2006
Feb 8, 2005 34466698R RESOLVE Non-Hazardous NOTED: WEST ELEVATION (FT. WASHINGTON AVE) SOUTHWEST CORNER PARAPET STEP CRACK IN BRICK WORK. ABOVE 5TH FLOOR CORNER ... $0 $0 Apr 21, 2005
Feb 8, 2005 34466702K RESOLVE Non-Hazardous NOTED BASEMENT STAIR "B" WALL PENETRATIONS NOT FIRE STOP AS REQUIRED REMEDY:PROVIDE REQUIRED FIRST STOPPING $0 $0 Apr 21, 2005
Feb 8, 2005 34466701Z RESOLVE Non-Hazardous NOTED BASEMENT BOILER ROOM STAIR "E" WALLS PENETRATED LACKING REQUIREDFIRE STOPPING REMEDY:PROVIDE REQUIRED FIRE STOP... $0 $0 Apr 21, 2005
Feb 8, 2005 34466699Z RESOLVE Non-Hazardous NOTED: ELEVATOR MACHINE ROOM - ROOF LEVEL WALL LADDER LOOSE (MISSING ANCHOR BOLTS) AT GOOSE NECK INTERIOR PARAPET ARE... $0 $0 Apr 21, 2005
Feb 8, 2005 34466697P RESOLVE Non-Hazardous NOTED: SOUTH ELEVATION, SOUTH WEST CORNER PARAPET STEP CRACK IN BRICK WORK ABOVE 5TH FLOOR CORNER WINDOW (LEFT SIDE).... $0 $0 Apr 21, 2005
Feb 8, 2005 34466704Y RESOLVE Non-Hazardous NOTED:CAFETERIA PUBLIC ASSEMBLY (CAPACITY 250)NO PUBLIC HARDWARE EXIT DOOR #1 REMEDY:PROVIDE REQUIRED PANIC HARDWARE $0 $0 Apr 21, 2005
Feb 8, 2005 34466705X RESOLVE Non-Hazardous NOTED PUBLIC ASSEMBLY CAFETERIA (CAPACITY 250)STAIRWELL "D" EXIT DOOR -NO PANIC HARDWARE REMEDY:PROVIDE REQUIRED PANI... $0 $0 Apr 21, 2005
Feb 8, 2005 34466706H RESOLVE Non-Hazardous NOTED PUBLIC ASSEMBLY CAFETERIA (CAPACITY 250)STAIRWELL "E"EXIT DOOR NO PANIC HARDWARE .REMEDY:PROVIDE REQUIRED PANIC... $0 $0 Apr 21, 2005
Feb 8, 2005 34466703M RESOLVE Non-Hazardous FAILURE TO PROVIDE ADEQUATE VENTILATION AS REQUIRED PER NYC BUILDINGS CODE WITHIN GAS METER ROOM REMEDY:PROVIDE REQUI... $0 $0 Apr 21, 2005
Feb 4, 2004 34431451P RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG DEFECTS NOTED:AT NEW ADDITION-STEP CRACKS AT PARAPET WALLS-EAST AND SOUTH.REMEDY:MA... $0 $0 May 6, 2004
Feb 4, 2004 34431453Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN BLDG.DEFECTS NOTED:1-RM # 517 CORROSION OF PLASTERCEILING AT DRAIN PIPE 2-LEAKING AT AREA EAST OF... $0 $0 May 6, 2004
Feb 4, 2004 34431454K RESOLVE Non-Hazardous FAILURE TO MAINTAIN BLDG.DEFECTS NOTED (1)4TH FLR-STAIR "G" KNOBS W/LOCKSETS 2-FIRE DRS LEFT OF STAIR "B" BROKEN CLOS... $0 $0 May 6, 2004
Feb 4, 2004 34431452R RESOLVE Non-Hazardous USE OF ILLEGAL HARDWARE.NOTED:1-5TH FLOOR STAIRS C&D,E&F AND G. 2-4TH FLOOR STAIRS "F" AND "D" 3-3RD FLOOR STAIRS "F"... $0 $0 May 6, 2004
Jan 23, 2003 34373105J RESOLVE Non-Hazardous PLACE OF ASSEMBLY EXIT DOOR SWINE AGAINST THE FLOW OF EGRESS. DEFECT. GYMNASIUM (OCCUPANCY 300) DOUBLE DOORS AT LEFT ... $0 $0 Apr 17, 2003
Jan 23, 2003 34373104H RESOLVE Non-Hazardous RE ISSUE FAILURE TO MAINTAIN BUILDING DEFECTS CRACKS ON WALL AT BASEMENT (BOILER SECTION) EAST & WEST ABOVE SUBWAY A,... $0 $0 Apr 17, 2003
Jan 23, 2003 34373200H RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING DEFECTS : NO DOOR CHECKS AT 5TH FL 507, 508, 509, 510, 511, 512, 513, 515, 516, 517, 518... $0 $0 Apr 17, 2003
Jan 23, 2003 34373196Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING DEFECTS DOOR DO NOT OPEN AT 2ND FL STAIR WAY E AT 1ST FL STAIRWAY C REMEDY : MAINTAIN BU... $0 $0 Apr 17, 2003
Jan 22, 2002 34315892M RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING STRUCTURAL CRACKS IN THE MASONARY BEADING WALL 16'-0"HIGH CRACKS ARE 3/8"&1/4"WIDE FROM ... $0 $0 Apr 11, 2002
Apr 23, 2001 34284452J RESOLVE Hazardous FAILURE TO MAINTAIN.DEFECTS.HOLE IN STAIRWAY WALL WITH HEAVY WATER DAMAGE WITH EXPOSED WIRE AND METAL FRAMING.LOCATIO... $0 $0 Oct 11, 2001
Apr 23, 2001 34284456R RESOLVE Non-Hazardous FAILURE TO MAINTAIN DEFECTS:CRACKED MASONRY WALLS.LOCATIONS.GYM AT RADIATOR.REMEDY:DO REPAIRS. $0 $0 Oct 11, 2001
Apr 23, 2001 34284453L RESOLVE Non-Hazardous FAILURE TO MAINTAIN,DEFECTS,CRACKED PLASTER CEILINGS,LOCATION:EXIT #7 5TH FL,3RD FL NEW WING AT DOUBLE ALARM BELLS RE... $0 $0 Oct 11, 2001
Apr 23, 2001 34284457Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN.DEFECTS CRACKED CONCRETE SUPPORT COLUMN AND SURROUNDING CONCRETE FLOORING.LOCATION:BOILER RM ADJA... $0 $0 Oct 11, 2001
Apr 23, 2001 34284455P RESOLVE Non-Hazardous FAILURE TO MAINTAIN.DEFECTS.CRACKED CONCRETE CEILINGS & BEAMS.LOCATIONGYM BEAMS NORTH AND EAST AND SOUTH AT FOUL LINE... $0 $0 Oct 11, 2001
Apr 23, 2001 34284454N RESOLVE Non-Hazardous FAILURE TO MAINTAIN,DEFECTS.CRACKED CONCRETE WALLS,LOCATIONS:IN CORRIDORS ADJACENT TO 4TH FL ELEV LOBBY NEW WING.3RD ... $0 $0 Oct 11, 2001
Apr 23, 2001 34284451H RESOLVE Non-Hazardous FAILURE TO MAINTAIN,DEFECTS,CRACKED PLASTER WALLS.LOCATION:BULKHEAD STAIR EXIT 4 UP + EXITS 5 UP + EXITS 8 UP 5TH FLO... $0 $0 Oct 11, 2001
Feb 22, 2000 34240269R RESOLVE Non-Hazardous FAILURE TO MAINTAIN DEFECT IS: A)THROUGHOUT FACADE WINDOWS ARE ROTTEN UNSAFE & UNOPENABLE. B)LARGE LONG CRACKS AT GRO... $0 $0 May 4, 2000
Jan 19, 1999 34198499X RESOLVE Hazardous FAILURE TO MAINTAIN BLDG EXTERIOR. NOTED: ROOF LEAKS-WATER PENETRATIONPEELING PLASTER ETC. NOTED: ENTRANCE RAILING RU... $0 $0 Apr 22, 1999
Nov 6, 1995 38052811P RESOLVE Non-Hazardous 73U16, 75U5, 74T7, 74M7. 74) NAME OF ELEVATOR CO AS PER CODE. 74) DATA PLATE TOP CAR $0 $0 Apr 18, 1996