ECB violations
Ps 173, Manhattan • Block 02142 • Lot 0154
139 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 18, 2009 | 34791934Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER - STAIRWAY G REMOVE DESKS & CHAIRS AT FLRS 2 & 3. REMEDY: MAINT... | $0 | $0 | Aug 13, 2009 |
| May 18, 2009 | 34791938X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER - BOILER RM - MAIN ENTRANCE - EXIT LIGHT PENETRATION NOT FIRE S... | $0 | $0 | Aug 13, 2009 |
| May 18, 2009 | 34791936M | ACTIVE | CLASS - 2 | ALTERED/CHANGED BUILDING OCCUPIED W/O A VALID C OF O. TEMP C.O. 121773EXPIRED 8/7/01. REMEDY: OBTAIN VALID C OF O AND... | $0 | $0 | Aug 13, 2009 |
| Sep 10, 2007 | 34589932X | RESOLVE | Hazardous | REISSUE# 34445602K. EXIT PASSAGEWAY/CORRIDOR IS OBSTRUCTED W/ SCHOOL FURNITURE (TABLES & CHAIRS) LOCATED PM CELLAR LE... | $0 | $0 | Nov 15, 2007 |
| Sep 10, 2007 | 34589931Y | RESOLVE | Hazardous | REISSUE# 34445698Y (PARTIAL). INTERIOR PLASTER IS SPALLING ON THE WALLS LOCATED AT THE ELEVATOR LOBBY ON THE 4TH FL L... | $0 | $0 | Nov 15, 2007 |
| May 17, 2006 | 34445602K | RESOLVE | Hazardous | EXIT PASSAGE OR CORRIDOR:REQUIRED WIDTH DECREASED BY OBSTRUCTION.NOTEDCELLAR STAIRWAY LEADS TO CELLAR LEVEL LOBBY FIL... | $0 | $0 | Aug 17, 2006 |
| May 17, 2006 | 34445601Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN BLDG INTERIOR.NOTED:NO DOOR CHECKS AT FOLLOWING RMS.517,518,520,506,414,407.DEFECTIVE DOOR CHECKS... | $0 | $0 | Aug 17, 2006 |
| May 17, 2006 | 34445603M | RESOLVE | Hazardous | USE OF ILLEGAL HARDWARE.NOTED:S/E EXIT DOORS W/ PADLOCK ON 1 DOOR(LOCKED OPEN).AT S/SIDE OF GYM,1 OF THE 2 SETS OF DO... | $0 | $0 | Aug 17, 2006 |
| May 17, 2006 | 34445698Y | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING. INTERIOR. NOTED: VERTICAL CRACKS IN PLASTER ADJACENT TO ELEVATOR LOBBIES ON FLOORS 2,3,... | $0 | $0 | Aug 17, 2006 |
| May 17, 2006 | 34445699X | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE/MAINTAIN FIRES STOPPING WHERE REQUIRED.NOTED:CELLARCONSTRUCTION WORK IN PROGRESS FOR OVER 1 YEAR C... | $0 | $0 | Aug 17, 2006 |
| Dec 15, 2005 | 38164128R | RESOLVE | Non-Hazardous | 85M07/38O02 (85-M-05) 5 YR TAG MISSING, PERFORM AND FILE TEST. | $0 | $0 | Mar 16, 2006 |
| Feb 8, 2005 | 34466698R | RESOLVE | Non-Hazardous | NOTED: WEST ELEVATION (FT. WASHINGTON AVE) SOUTHWEST CORNER PARAPET STEP CRACK IN BRICK WORK. ABOVE 5TH FLOOR CORNER ... | $0 | $0 | Apr 21, 2005 |
| Feb 8, 2005 | 34466702K | RESOLVE | Non-Hazardous | NOTED BASEMENT STAIR "B" WALL PENETRATIONS NOT FIRE STOP AS REQUIRED REMEDY:PROVIDE REQUIRED FIRST STOPPING | $0 | $0 | Apr 21, 2005 |
| Feb 8, 2005 | 34466701Z | RESOLVE | Non-Hazardous | NOTED BASEMENT BOILER ROOM STAIR "E" WALLS PENETRATED LACKING REQUIREDFIRE STOPPING REMEDY:PROVIDE REQUIRED FIRE STOP... | $0 | $0 | Apr 21, 2005 |
| Feb 8, 2005 | 34466699Z | RESOLVE | Non-Hazardous | NOTED: ELEVATOR MACHINE ROOM - ROOF LEVEL WALL LADDER LOOSE (MISSING ANCHOR BOLTS) AT GOOSE NECK INTERIOR PARAPET ARE... | $0 | $0 | Apr 21, 2005 |
| Feb 8, 2005 | 34466697P | RESOLVE | Non-Hazardous | NOTED: SOUTH ELEVATION, SOUTH WEST CORNER PARAPET STEP CRACK IN BRICK WORK ABOVE 5TH FLOOR CORNER WINDOW (LEFT SIDE).... | $0 | $0 | Apr 21, 2005 |
| Feb 8, 2005 | 34466704Y | RESOLVE | Non-Hazardous | NOTED:CAFETERIA PUBLIC ASSEMBLY (CAPACITY 250)NO PUBLIC HARDWARE EXIT DOOR #1 REMEDY:PROVIDE REQUIRED PANIC HARDWARE | $0 | $0 | Apr 21, 2005 |
| Feb 8, 2005 | 34466705X | RESOLVE | Non-Hazardous | NOTED PUBLIC ASSEMBLY CAFETERIA (CAPACITY 250)STAIRWELL "D" EXIT DOOR -NO PANIC HARDWARE REMEDY:PROVIDE REQUIRED PANI... | $0 | $0 | Apr 21, 2005 |
| Feb 8, 2005 | 34466706H | RESOLVE | Non-Hazardous | NOTED PUBLIC ASSEMBLY CAFETERIA (CAPACITY 250)STAIRWELL "E"EXIT DOOR NO PANIC HARDWARE .REMEDY:PROVIDE REQUIRED PANIC... | $0 | $0 | Apr 21, 2005 |
| Feb 8, 2005 | 34466703M | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ADEQUATE VENTILATION AS REQUIRED PER NYC BUILDINGS CODE WITHIN GAS METER ROOM REMEDY:PROVIDE REQUI... | $0 | $0 | Apr 21, 2005 |
| Feb 4, 2004 | 34431451P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG DEFECTS NOTED:AT NEW ADDITION-STEP CRACKS AT PARAPET WALLS-EAST AND SOUTH.REMEDY:MA... | $0 | $0 | May 6, 2004 |
| Feb 4, 2004 | 34431453Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG.DEFECTS NOTED:1-RM # 517 CORROSION OF PLASTERCEILING AT DRAIN PIPE 2-LEAKING AT AREA EAST OF... | $0 | $0 | May 6, 2004 |
| Feb 4, 2004 | 34431454K | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG.DEFECTS NOTED (1)4TH FLR-STAIR "G" KNOBS W/LOCKSETS 2-FIRE DRS LEFT OF STAIR "B" BROKEN CLOS... | $0 | $0 | May 6, 2004 |
| Feb 4, 2004 | 34431452R | RESOLVE | Non-Hazardous | USE OF ILLEGAL HARDWARE.NOTED:1-5TH FLOOR STAIRS C&D,E&F AND G. 2-4TH FLOOR STAIRS "F" AND "D" 3-3RD FLOOR STAIRS "F"... | $0 | $0 | May 6, 2004 |
| Jan 23, 2003 | 34373105J | RESOLVE | Non-Hazardous | PLACE OF ASSEMBLY EXIT DOOR SWINE AGAINST THE FLOW OF EGRESS. DEFECT. GYMNASIUM (OCCUPANCY 300) DOUBLE DOORS AT LEFT ... | $0 | $0 | Apr 17, 2003 |
| Jan 23, 2003 | 34373104H | RESOLVE | Non-Hazardous | RE ISSUE FAILURE TO MAINTAIN BUILDING DEFECTS CRACKS ON WALL AT BASEMENT (BOILER SECTION) EAST & WEST ABOVE SUBWAY A,... | $0 | $0 | Apr 17, 2003 |
| Jan 23, 2003 | 34373200H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING DEFECTS : NO DOOR CHECKS AT 5TH FL 507, 508, 509, 510, 511, 512, 513, 515, 516, 517, 518... | $0 | $0 | Apr 17, 2003 |
| Jan 23, 2003 | 34373196Y | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING DEFECTS DOOR DO NOT OPEN AT 2ND FL STAIR WAY E AT 1ST FL STAIRWAY C REMEDY : MAINTAIN BU... | $0 | $0 | Apr 17, 2003 |
| Jan 22, 2002 | 34315892M | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING STRUCTURAL CRACKS IN THE MASONARY BEADING WALL 16'-0"HIGH CRACKS ARE 3/8"&1/4"WIDE FROM ... | $0 | $0 | Apr 11, 2002 |
| Apr 23, 2001 | 34284452J | RESOLVE | Hazardous | FAILURE TO MAINTAIN.DEFECTS.HOLE IN STAIRWAY WALL WITH HEAVY WATER DAMAGE WITH EXPOSED WIRE AND METAL FRAMING.LOCATIO... | $0 | $0 | Oct 11, 2001 |
| Apr 23, 2001 | 34284456R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECTS:CRACKED MASONRY WALLS.LOCATIONS.GYM AT RADIATOR.REMEDY:DO REPAIRS. | $0 | $0 | Oct 11, 2001 |
| Apr 23, 2001 | 34284453L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN,DEFECTS,CRACKED PLASTER CEILINGS,LOCATION:EXIT #7 5TH FL,3RD FL NEW WING AT DOUBLE ALARM BELLS RE... | $0 | $0 | Oct 11, 2001 |
| Apr 23, 2001 | 34284457Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN.DEFECTS CRACKED CONCRETE SUPPORT COLUMN AND SURROUNDING CONCRETE FLOORING.LOCATION:BOILER RM ADJA... | $0 | $0 | Oct 11, 2001 |
| Apr 23, 2001 | 34284455P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN.DEFECTS.CRACKED CONCRETE CEILINGS & BEAMS.LOCATIONGYM BEAMS NORTH AND EAST AND SOUTH AT FOUL LINE... | $0 | $0 | Oct 11, 2001 |
| Apr 23, 2001 | 34284454N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN,DEFECTS.CRACKED CONCRETE WALLS,LOCATIONS:IN CORRIDORS ADJACENT TO 4TH FL ELEV LOBBY NEW WING.3RD ... | $0 | $0 | Oct 11, 2001 |
| Apr 23, 2001 | 34284451H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN,DEFECTS,CRACKED PLASTER WALLS.LOCATION:BULKHEAD STAIR EXIT 4 UP + EXITS 5 UP + EXITS 8 UP 5TH FLO... | $0 | $0 | Oct 11, 2001 |
| Feb 22, 2000 | 34240269R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECT IS: A)THROUGHOUT FACADE WINDOWS ARE ROTTEN UNSAFE & UNOPENABLE. B)LARGE LONG CRACKS AT GRO... | $0 | $0 | May 4, 2000 |
| Jan 19, 1999 | 34198499X | RESOLVE | Hazardous | FAILURE TO MAINTAIN BLDG EXTERIOR. NOTED: ROOF LEAKS-WATER PENETRATIONPEELING PLASTER ETC. NOTED: ENTRANCE RAILING RU... | $0 | $0 | Apr 22, 1999 |
| Nov 6, 1995 | 38052811P | RESOLVE | Non-Hazardous | 73U16, 75U5, 74T7, 74M7. 74) NAME OF ELEVATOR CO AS PER CODE. 74) DATA PLATE TOP CAR | $0 | $0 | Apr 18, 1996 |