1360-1378 St Nicholas Avenue, Manhattan • Block 02153 • Lot 0001
151 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 19, 2023 | 35662409X | RESOLVE | CLASS - 2 | PROJECT INFORMATION PANEL/SIDEWALK SHED PARAPET PANEL/CONSTRUCTION SIGN NOT PROVIDED OR NOT INCOMPLIANCE WITH SECTION... | $0 | $0 | Jun 29, 2023 |
| Nov 2, 2022 | 39508646J | RESOLVE | CLASS - 2 | OBSERVED SUSPENDED SCAFFOLD AT EXP#3, NORTH DROP, WITH OUTRIGGER BEAM SET-UP BUILT CONTRARY TO APPROVED CD-5: DOUBLE ... | $0 | $0 | Dec 22, 2022 |
| May 6, 2022 | 39501180P | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION OBSERVED, SIDEWALK SHED ERECTED AT EXPOSURE #1,2&4 , SIDEWALK SHED WAS NOT INASTALLED AS PE... | $5,000 | $0 | Jun 23, 2022 |
| Oct 8, 2021 | 37022018X | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7C,8C,AND 9C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN ... | $1,250 | $0 | Jul 7, 2022 |
| Oct 8, 2021 | 37022017Y | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7C,8C,AND 9C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN ... | $1,250 | $0 | Jul 7, 2022 |
| Aug 17, 2021 | 35587631J | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS SHARP EDGES ONSIDEWALK SHED. NOTED: AT TIME OF INSPECTION OF ... | $2,400 | $0 | Feb 10, 2022 |
| Mar 22, 2021 | 35544627R | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPORVED AMNEDMNETS CD5 NOTE AT THE TIME OF MY INSPEC... | $2,500 | $0 | Aug 19, 2021 |
| Mar 22, 2021 | 35544628Z | RESOLVE | CLASS - 2 | BC3314.3.2=NO DESIGN DRAWINGS FOR ELECTRICAL C HOOKS NOTE AT THE TIME OF MY INSPECTION I OBSERVED A C HOOK SCAFFOLD I... | $1,250 | $0 | Jun 3, 2021 |
| Dec 25, 2020 | 35475000R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED APPROX 70' OF SIDEWALK SHED PARA... | $5,000 | $0 | Jan 13, 2022 |
| Aug 6, 2020 | 35500104N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN SIDEWALK SHED @TIME OF INSPECTION IN RESPONSE TO COMPLINAT #1549519 OBSERVED UNSAFE SIDEALK SHED ... | $2,400 | $0 | Oct 15, 2020 |
| Aug 6, 2020 | 35500103L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN SIDEWALK SHED @TIME OF INSPECTION, IN RESPONSE TO COMPLAINT #1549519, OBSERVED UNSAFE SIDEWALK SH... | $1,200 | $0 | Oct 15, 2020 |
| Feb 13, 2020 | 37018559R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURT... | $625 | $0 | Jun 25, 2020 |
| Feb 13, 2020 | 37018560Y | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURT... | $0 | $0 | Dec 10, 2020 |
| Oct 15, 2019 | 35447086Z | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION NOTE:AT TIME OFINSPECTION OBSERVED SWS AT A 32 STORY BLDG VERT... | $2,430 | $0 | Dec 26, 2019 |
| Oct 5, 2019 | 35432191Z | RESOLVE | CLASS - 2 | FAILURE TO POST NOTICE OF TENANT PROTECTION PLAN: AT THE TIME OF INSPECTION CONDUCTED WALK THROUGH OF THE BLDG. I DID... | $0 | $0 | Mar 4, 2021 |
| Oct 5, 2019 | 35432190R | RESOLVE | CLASS - 2 | FAILURE TO DISTRIBUTE OR POST SAFE CONSTRUCTION BILL OR RIGHTS. NOTED:AT TIME OF INSPECTION CONDUCTED WALK THROUGH OF... | $0 | $0 | Mar 4, 2021 |
| Oct 2, 2018 | 35346220H | RESOLVE | CLASS - 1 | UNLAWFUL ACT. FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT & CERTIFY SUMMONS#35346181Y;353134... | $0 | $0 | Nov 29, 2018 |
| Aug 13, 2018 | 35346181Y | RESOLVE | CLASS - 1 | AN UNLAWFUL ACT.FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.FAILURE TO CORRECT & CERTIFY SUMMONS #'S 35313416Z, ... | $0 | $0 | Nov 29, 2018 |
| Jun 22, 2018 | 38263934P | RESOLVE | CLASS - 1 | 97X17,99BB05. 97X17-UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE. AS PER 1RCNY 11-02. RMDY; RESTORE TO SE... | $625 | $0 | Oct 4, 2018 |
| Jun 20, 2018 | 35318872P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AS PER 1RCNY 103-04.NOTEDAT TIME OF INSPECTION EAST ELEVATION EXP1 LOOSE... | $2,500 | $0 | Oct 4, 2018 |
| Jun 20, 2018 | 35318871N | RESOLVE | CLASS - 1 | FAILURE TO TAKE AND PROVIDE SAFETY MEASURES SIDEWALK SHED, NETTING ETCWHERE REQUIRED TO PROTECT AND ENSURE PUBLIC SAF... | $10,000 | $0 | Oct 4, 2018 |
| Jun 19, 2018 | 35318869Y | RESOLVE | CLASS - 1 | FAIURE TO TAKE AND PROVIDE SAFETY MEASURES.SIDEWALK SHED NETTING ETC WHERE REQD TO PROTECT AND SECURE PUBLIC SAFETY F... | $10,000 | $0 | Oct 4, 2018 |
| Jun 19, 2018 | 35318870L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXT BLDDG FACADE AS PER 1RCNY 103-04.NOTED AT TIME OF INSPECTION WEST ELEVATION EXP 1,FLS 31AND 3... | $2,500 | $0 | Oct 4, 2018 |
| May 23, 2018 | 35313418M | RESOLVE | CLASS - 1 | UNAPPROVED, UNSAFE, UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES ARE WIRING IN USE. THE... | $0 | $0 | Sep 13, 2018 |
| May 23, 2018 | 35313416Z | RESOLVE | CLASS - 1 | EC300.16 A SUPPORT BUSHING, LOCATED AT THE TOP OF A VERTICAL CONDUIT AT CABINET OR PULL BOX,USED TO PREVENT THE WEIGH... | $400 | $0 | Nov 29, 2018 |
| May 23, 2018 | 35313417K | RESOLVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS,DEVICES APPLIANCES OR WIRING IN USE. BASEMENT... | $400 | $0 | Nov 29, 2018 |
| Dec 14, 2017 | 38259916J | RESOLVE | CLASS - 1 | 05A10)CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH DISABLED AND RENDERED INOPERATIVE. THIS IS A SAFETY... | $2,500 | $0 | Feb 1, 2018 |
| Jul 25, 2017 | 38256886Y | RESOLVE | CLASS - 2 | 67L10 IN CAR COMMUNICATION DEFECTIVE NEEDS TO BE REPAIRED. | $500 | $0 | Apr 26, 2018 |
| Jul 25, 2017 | 38256887X | RESOLVE | CLASS - 2 | 67L10 IN CAR COMMUNICATION DEFECTIVE NEEDS TO BE REPAIRED. | $250 | $0 | Sep 14, 2017 |
| Jul 25, 2017 | 38256885M | RESOLVE | CLASS - 2 | 67L10 IN CAR COMMUNICATION DEFECTIVE NEES TO BE REPAIRED. | $500 | $0 | Apr 26, 2018 |
| Jan 18, 2017 | 38252513N | RESOLVE | CLASS - 2 | 02B10,70O02,68B07. 02B10-REPAIR PHONE; 70O02-CLEAN PIT; 68B-PROVIDE MAINTENANCE CONTROL PROGRAM. | $2,500 | $0 | Mar 9, 2017 |
| Nov 15, 2016 | 38251281Z | RESOLVE | CLASS - 1 | 97X10 FAILURE TO MAINTAIN BLG IN CODE COMPLIANT MANNER SERVICE ELEVATOR AS PER CODE. UPON INSPECTION THE DEVICE IS FO... | $625 | $0 | Jan 26, 2017 |
| Nov 1, 2016 | 38250961H | RESOLVE | CLASS - 1 | 97X10/FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER SERVICE EQUIPMENT ELEVATOR AS PER.BC3001.2&27-987.DOB UPON IN... | $250 | $0 | Jan 26, 2017 |
| Nov 1, 2016 | 38250960X | RESOLVE | CLASS - 1 | 97X10/FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER SERVICE EQUIPMENT ELEVATOR AS PER BC3001.2&27-987.DOB UPON IN... | $250 | $0 | Jan 26, 2017 |
| Sep 29, 2015 | 38238594N | RESOLVE | CLASS - 2 | 05E01,70O02,40P07,15M07. 05E01-CAR DOOR RUBBING ADJUST CAR DOOR ON SADDLE; 70O02-PIT DIRTY CLEAN ALL 3 PITS; 40P07-MA... | $0 | $0 | Nov 19, 2015 |
| Sep 10, 2015 | 38238588R | RESOLVE | CLASS - 2 | 100P07,67B07. 100P07-CALLED SUPER NO MEANS OF ACCESS PROVIDED TO CHECKMOTOR ROOM HE SPOKE TO ME AND NEVER SHOWED UP; ... | $250 | $0 | Oct 29, 2015 |
| Sep 4, 2015 | 35133569L | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SAFETY MEASURES (SIDEWALK SHED) WHERE REQUIRED TO PROTECT & SECURE PUBLIC FROM UNSAFE FACADE AS PE... | $2,400 | $0 | Jan 28, 2016 |
| Sep 4, 2015 | 35133570Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG,WEST ELEVATION EXP1 DETERIORATING DECORATIVE STONES ABOVE ENTRANCE.DISLODGED METAL ... | $0 | $0 | Oct 22, 2015 |
| Mar 7, 2014 | 38230453N | RESOLVE | CLASS - 1 | 42N11,08B10,14M07,08J10,05E01,05H11,42A10,97B01,16M07. 42N11-FUSE #15 BYPASSED REPLACE; 08B10-CAR OUT OF LEVEL REPAIR... | $1,000 | $0 | Jul 10, 2014 |
| Mar 7, 2014 | 38230452L | RESOLVE | CLASS - 2 | 97L10 - ENTIRE DEVICE IS OUT OF SERVICE REPAIR RESTORE SERVICE. | $0 | $0 | Apr 24, 2014 |
| Dec 2, 2013 | 35073638Y | RESOLVE | CLASS - 2 | WORK W/O A PERMIT WORK NOTED: HAVIN ERECTED FULL HEIGHT PARTITIONS IN LIVING ROOM AND DINING ROOM TO CREATE TWO EXTRA... | $800 | $0 | Apr 3, 2014 |
| Sep 18, 2013 | 38228528X | RESOLVE | CLASS - 2 | 97B10- RESTORE TO SERVICE. | $250 | $0 | Nov 7, 2013 |
| Jan 15, 2013 | 34986787H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES.NOTED:AT 1ST STORY PARKING GARAGE NORTH,EAST CORNER,COPING AND ... | $5,000 | $0 | Mar 7, 2013 |
| Nov 2, 2012 | 35000535Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS AND/OR APPURTENANCES. NOTE: PARTIAL COLLAPSE OF PARAPIT WALL @ 2ND LEVEL ROOF @ EXP 4 ... | $1,000 | $0 | Jan 31, 2013 |
| Oct 31, 2012 | 34995139Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: APPROX 50FT SECTION OF PARAPET WALL AT NORTH EAST CORNER OF 1... | $1,000 | $0 | Jan 31, 2013 |
| Aug 7, 2012 | 34993203K | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. WORK NOTED: IN APT #24A, HAVING ERECTED FULL HEIGHTPARTITIONS IN LEAVING ROOM AND KITCHEN AREA TO ... | $800 | $0 | Sep 27, 2012 |
| Apr 3, 2012 | 38221383M | RESOLVE | CLASS - 2 | 03M11,08V01,10H11,12Q03,14M11,29Q03,34O02,39O02,67M07,68B07,72Q03,73O02,74O02: 03M11;REPLACE MISSING HAND RAIL IN CAR... | $2,500 | $0 | May 24, 2012 |
| Feb 11, 2011 | 38214537K | RESOLVE | CLASS - 2 | 10H07 17H07 14M07 39O02 70O02. 10H07-CAR DOOR GIBS ARE WORN PROVIDE. 17H07-HOISTWAY DOOR GIBS ARE WORN REPLACE WERE N... | $250 | $0 | Jun 30, 2011 |
| Feb 11, 2011 | 38214538M | RESOLVE | CLASS - 2 | 10H07 17H07 14M07 70O02 39O02. | $250 | $0 | Jun 30, 2011 |
| Sep 18, 2010 | 34852031Y | RESOLVE | CLASS - 2 | ILLEGAL USE IN A RESIDENTIAL DISTRICT. FABRIC DESIGN CLASS OUT OF APT 20D. REMEDY: DISCONTINUE ILLEGAL USE. | $400 | $0 | Nov 18, 2010 |