Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 10, 2026 39199912R ACTIVE CLASS - 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR TAMPERED WITH AND RENDERED INOPERATIVE. (NYC ADMIN. CODE 28-304.1; 28-301.1). RE... $1,250 $1,250 Oct 15, 2026
Jul 24, 2025 39154757R ACTIVE CLASS - 2 I FOUND A ROCKMILL MP150 STEAM BOILER WITH SMALL HOLES ON THE FLUE PIPE/HOLE AROUND CHIMNEY BASE/MISSING BODY DRAINS ... $6,250 $6,250 Oct 26, 2026
Sep 19, 2024 39125291L ACTIVE CLASS - 1 DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE... $1,250 $0 May 20, 2025
Jun 20, 2024 39117295Z ACTIVE CLASS - 1 CEASE USE: DOOR ZONE RESTRICTOR NOT WORKING PROPERLY. THIS SAFETY DEVICE PREVENTS THE CAB DOOR FROM OPENING IN BETWEE... $1,250 $0 Jun 5, 2025
Jul 26, 2023 39091062P RESOLVE CLASS - 2 FOUND BOLTS AND LATCHES ON BOILER DOOR, DISCHARGE PIPES ON SAFETY RELIEF VALVES NOT PROPERLY SUPPORTED, REAR CHAMBER ... $0 $0 Oct 5, 2023
Jul 20, 2023 39090656H RESOLVE CLASS - 2 CLASS 2: CAB LIGHT INOPERATIVE REPAIR. EVACUATION SIGNS MISSING PROVIDE REQUIRED SIGNAGE AT EVERY FLOOR. CAR FLOOR NO... $0 $0 Sep 28, 2023
Mar 29, 2023 39082580K RESOLVE CLASS - 1 REPAIR PIT LIGHT., PROVIDE IN-CASE OF FIRE SIGNS ON ALL FLOORS., CLEAN HOIST ROPES., CLEAN HOIST MACHINE., SEAL HOIST... $3,125 $0 Jun 8, 2023
Sep 2, 2022 39069404P RESOLVE CLASS - 2 I OBSERVED ON THE 1ST FLOOR ABOVE THE MAIL BOXES A LIGHT FIXTURE THAT IS HANGING FROM A WIRE INSIDE THE ELECTRICAL BO... $0 $0 Oct 20, 2022
Apr 8, 2022 39059872R RESOLVE CLASS - 1 FOUND PLUNGER OF DOOR RESTRICTOR TIED UP BY WIRE. DOOR RESTRICTOR IS NOT WORKING. CEASE USED. REMOVE WIRE, REPAIR AND... $1,250 $0 May 26, 2022
Dec 23, 2021 39053373P RESOLVE CLASS - 1 FOUND INSULATION TAPE USED ON THE PLUNGER OF DOOR RESTRICTOR. DOOR RESTRICTOR IS NOT WORKING. CEASE USED. REMOVE INSU... $1,250 $0 Feb 10, 2022
Sep 16, 2021 39047639M RESOLVE CLASS - 1 AT TIME OF INSPECTION OBSERVED INADEQUATE HARDWARE ON EMERGENCY EXIT DOOR FROM BASEMENT LEVEL LAUNDRY ROOM. ERECTED K... $1,250 $0 Nov 4, 2021
Sep 3, 2020 35539091L RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADE AND APPURTENANCES AT THE TIME OF INSEPCTION VIEW AT EXPOSURE 1 STE... $1,250 $0 Aug 19, 2021
Sep 3, 2020 35539093P RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS NOTE ... $1,250 $0 Mar 10, 2022
Jul 9, 2020 35538679H RESOLVE CLASS - 1 1RCNY 103-04(6)1-OWNER FAILURE TO REPAIR SWAP CONDITIOSN IN A TIMLEY MANNOR ON 7-92-2020 OBSERVED EXISTING SWARMP AT ... $1,250 $0 Mar 10, 2022
Apr 7, 2015 38235825H RESOLVE CLASS - 2 70O02,40O02,56Y10,98M07,100M07. 70-PIT DIRTY CLEAN; 40-MACHINE ROOM DIRTY CLEAN; 56-REPAIR SERIOUS OIL LEAK ON MACHIN... $500 $0 May 28, 2015
Mar 5, 2014 38230298M RESOLVE CLASS - 2 08J01,97O02,100B01,39Y02,96M07,52M07,56Y10,100M07,77M07,35D16. 08J01- ADJUST FLOOR STOPS NOT LEVEL; 97O02-CLEAN ENTIR... $500 $0 Apr 24, 2014
Aug 12, 2013 35009999N RESOLVE CLASS - 2 FAILED TO OBTAIN A TEMPORARY CONSTRUCTION PERMIT PRIOR TO INSTALLATIONUSE OF SIDEWALK SHED NOTED-UPON INSPECTION SIDE... $0 $0 Oct 31, 2013
Aug 1, 2013 35009944X RESOLVE CLASS - 2 TEMP CONSTRUCTION EQUIPMENT ON SITE - EXPIRED PERMIT. - SHED AT EXP #1EXPIRED PERMIT 5.3.13. REMEDY: COMPLY W/CODE. $4,000 $0 Sep 19, 2013
Jul 23, 2012 34952146M RESOLVE CLASS - 2 FOLLOWING THE RECEIPT OF A PERMIT TO ERECT A SIDEWALK SHED THE PERMIT HOLDER SHALL POST A READILY VISIBLE SIGN ON THE... $800 $0 Apr 11, 2013
Jun 8, 2012 34973656P RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A C/C W/THE DOB FOR NOV #34924800J ISSUED ON 8.18.11 PURSUANT TO... $2,000 $0 Jul 26, 2012
Aug 18, 2011 34924800J RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. BRICK PARAPET WALROOF LEVEL IS CRACKED LEANING IN WOOD, MISSING ... $5,000 $0 Nov 3, 2011
Apr 19, 2011 38215947H RESOLVE CLASS - 2 14M07 35Q03 56Y13 81M07. 35Q03-INSTALL GUARD FOR ELECTRICAL BOX TOP OF CAR. $2,500 $0 Aug 18, 2011
Jun 22, 2010 38211551N RESOLVE CLASS - 2 98BB05,21K10,34O02. 21K- INTERLOCK ROLLER ARMS- ALL FLOORS $500 $0 Feb 3, 2011
Apr 2, 2008 38183137M RESOLVE Non-Hazardous CU 58H11.51H11.431010.41D06.59B07.55Y10.55O02.38O02.86BB05.10M07.52B14.30M07.05J10.08V10. CU 58H11 CAR BRAKE SHOE ARE... $800 $0 May 22, 2008
Mar 25, 2008 38183307X RESOLVE Non-Hazardous 21Q03.66O02.83X10. 21Q03 INSTALL COVER FOR BASEMENT INTERLOCK 83X10 REPAIR ELEVATOR & RETURN TO SERVICE SO THAT A COM... $0 $0 May 15, 2008
Feb 26, 2007 38163514K RESOLVE Non-Hazardous 39P16,66O02,72B14,38Y02,10R11.39P16-PROVIDE ACCESS TO MOTOR SO THAT A PROPER INSPECTION CAN BE DONE BY THIS DEPT.10R1... $180 $0 Apr 19, 2007
Feb 2, 2006 38157336X RESOLVE Non-Hazardous 05J01/08V01/12B10/12Q03/03B09/84Q03/20B11/41B09/38O02/66O02. (05-J-01)ADJUST CAR TO REMOVE GAB ON LEADING EDGE (08-V-... $180 $0 Aug 24, 2006
Jan 27, 2005 32047080X RESOLVE Non-Hazardous 50/50A/50B/50C. 50)STEAM PIPE LEAKING UNDER APT #1F "CHECKED FOR CARBON MONOXIDE 0PPM".50A)BOILER REAR SIGHT GLASS MI... $350 $0 Apr 28, 2005
Jun 7, 2000 38097996J RESOLVE Non-Hazardous 73M12,50Y14,35I11,46Y09,47B15,30O02,57O02,25O06.73-INSTALL SAFETY PLATE COVER ON CAB FLOORING.(50)CLEAN AND SEAL MACH... $0 $0 Jul 27, 2000
Nov 19, 1997 38065123Y RESOLVE Non-Hazardous 28H,75U,57O,35P, $0 $0 Jan 22, 1998
Oct 19, 1993 38037909H RESOLVE Non-Hazardous 37R, 74B, 75B. 37-REMOVE JUMPER OFF OF CONTROLLER. 74-PROPERLY TAG GOVERNOR $100 $0 Jan 6, 1994
Apr 14, 1992 38023641Z RESOLVE Non-Hazardous 03M,11Q,11L,17Q,23L,28L,34#,34I,36L,37G,38L,39A,46H,50Y,52L,57O,61K,61M,73O,03L, 03- CAPACITY PLATE 11L- PROPERLY WIR... $0 $0 May 28, 1992
May 30, 1991 38011053Y RESOLVE Non-Hazardous 09L;28L;22D;73O;50Y; $0 $0 May 28, 1992