ECB violations
2-6 Wadsworth Terrace, Manhattan • Block 02170 • Lot 0307
28 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 4, 2016 | 35197508K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. NOTED: @ TIME OF INSP, ALL FLRS OF BASEMENT APT ARE NOT LEVEL. S... | $250 | $0 | Sep 22, 2016 |
| Jun 24, 2014 | 35024549L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG.EAST ELEVATION EXP3 HAS IMPROPERLY INSTAKKED A/C UNITS.SOUTH ELEVATION EXP 4 DERERI... | $500 | $0 | Aug 14, 2014 |
| Nov 23, 2009 | 32066545K | RESOLVE | CLASS - 3 | 50/50-FOUR (PRESTROL'S) ON ONE MANIFOLD | $500 | $0 | Jan 14, 2010 |
| Mar 19, 2007 | 38165382R | RESOLVE | Non-Hazardous | 16J01.16-ADJUST ON 5TH FL & WHERE EVER NECESSARY-ELEVATOR STOPS WHEN DOOR IS PULLED. | $0 | $0 | May 10, 2007 |
| Mar 19, 2007 | 38165042K | RESOLVE | Non-Hazardous | 83X10/.83-X-10-RESTORE ELEVATOR BACK TO SERVICE SO THAT A PROPER INSPECTION CAN BE DONE BY THIS DEPARTMENT | $350 | $0 | May 10, 2007 |
| Mar 19, 2007 | 38165381P | RESOLVE | Non-Hazardous | 83X10/.83-RESTORE TO SERVICE FOR A PROPER INSPECTION. | $0 | $0 | May 10, 2007 |
| Mar 6, 2007 | 38165078M | RESOLVE | Hazardous | 83X10/83-RETURN TO SERVICE. | $0 | $0 | Apr 26, 2007 |
| Jun 7, 2006 | 38159090Y | RESOLVE | Non-Hazardous | 39Z10/36D06 39-REPAIR PIPING AND DRAINAGE IN MOTOR ROOM WATER ACCUMULATES IN MOTOR ROOM AND UNDER MAIN LINE DISCONNEC... | $0 | $0 | Jul 27, 2006 |
| Dec 2, 2005 | 38156094H | RESOLVE | Hazardous | 36I11/43H11/51H11. CEASE USE. CU-36 COUNTERWEIGHT DEFLECTOR SHEAVE COLLAPSE, REPLACE CU-43- HOIST SHEAVE WORN REPLACE... | $800 | $0 | Jul 24, 2008 |
| Mar 16, 2005 | 34433725M | RESOLVE | Non-Hazardous | PIPING AND/OR EQUIPMENT INSTALLED IMPROPERLY.AT TIME OF INSPECTION FOUND COMMERCIAL GAS DRYERS WERE NOT BOLTED TO FLO... | $350 | $0 | May 5, 2005 |
| Mar 16, 2005 | 34433724K | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED.AT TIME OF INSPECTION FOUND LAUNDRY ROOM IN BASEME... | $400 | $0 | May 5, 2005 |
| Dec 10, 2004 | 38150159M | RESOLVE | Non-Hazardous | 43H08/21Q03/55Y10/55O02/33O02/71Q03/34Q03 21-PROVIDE COVERS BASEMENT 2ND AND 3RD FLOORS 71-ELECTRICAL WIRES EXPOSED F... | $180 | $0 | Jan 27, 2005 |
| Aug 1, 2000 | 38106965Z | RESOLVE | Non-Hazardous | 35D06/46#12/50H11/33D12/14I10 - 35 REMOVE STORAGE MOTOR ROOM DEDICATED SPACE FOR ELEVATOR EQUIPMENT 46 REPLACE WORN, ... | $180 | $0 | Sep 22, 2000 |
| Aug 1, 2000 | 38106966K | RESOLVE | Non-Hazardous | 50E11 - 50 ELIMINATE KNOCK IN MACHINE GEARING. | $180 | $0 | Sep 22, 2000 |
| Nov 5, 1999 | 38091979K | RESOLVE | Non-Hazardous | 8V1,22L6,28H11,33I11,57O2,9H12,35P17. 33-SKYLIGHT. | $0 | $0 | Jan 13, 2000 |
| Nov 5, 1999 | 38091980H | RESOLVE | Non-Hazardous | 9H12,22L6,55X11,49B15,57O2,35P17. | $180 | $0 | Jan 13, 2000 |
| Mar 22, 1995 | 38047620X | RESOLVE | Non-Hazardous | 50Y,50F,54U,73O,61I,40L,33W,75U,31Q,40M,63H. 40 PLATE. | $100 | $0 | Oct 19, 1995 |
| Mar 22, 1995 | 38047619Z | RESOLVE | Non-Hazardous | 54U,50Y,63H,73O,57Z,40L,20D,8V,52J,18Q,55X,33X,75U,31Q,40M. 33-LIGHT. 40 DATA PLATE. | $100 | $0 | Oct 19, 1995 |
| Dec 10, 1993 | 38039169K | RESOLVE | Non-Hazardous | 08V,21L,28L,37G,39L,46L,51F,51L,50Y,50Y,57O,58O,59O. 46 FOR PROPER RUN BY. | $250 | $0 | Jan 27, 1994 |
| Aug 23, 1993 | 38036371K | RESOLVE | Non-Hazardous | 74#,02X,14#,03#. 74 CITY IDENTIFICATION DEVICE NUMBERS DAMAGED 03 CAPACITY PLATE. | $0 | $0 | Oct 28, 1993 |
| Aug 23, 1993 | 38036373Y | RESOLVE | Non-Hazardous | 74#,51F,51L,28L,57O,08V. 74 CITY IDENTIFICATION NUMBERS. | $0 | $0 | Oct 28, 1993 |
| Aug 23, 1993 | 38036370Z | RESOLVE | Non-Hazardous | 74#,57Z,14M,03#. 74 CITY IDENTIFICATION TAGS. 03 CAPACITY PLATE | $0 | $0 | Oct 28, 1993 |
| Aug 23, 1993 | 38036372M | RESOLVE | Non-Hazardous | 54M 74# 57O 47L 54 MAIN LINE COVER 74 CITYIDENTIFICATION NUMBERS | $0 | $0 | Oct 28, 1993 |
| Dec 7, 1992 | 38017177N | RESOLVE | Non-Hazardous | 08V,35Q,36T,55O, | $1,000 | $0 | Apr 8, 1993 |
| Apr 1, 1992 | 38023595R | RESOLVE | Non-Hazardous | 15#,18R,28L,30O,33I,36T,50Y,30M,15H,58O,59O,54L, 15-18 ROOF DOOR- CEASE USE UNTIL ITESMS 15-AND 18 ARE REPAIRED. 33. ... | $500 | $0 | May 15, 1992 |
| Apr 1, 1992 | 38023596Z | RESOLVE | Non-Hazardous | 03M,08V,28L,39L,40L,58O,59O,54L,05L, 03. CAPACITY PLATE. 28. TOP SET 05. WAKE CUT-OUT FOR VISION PANEL. | $0 | $0 | May 15, 1992 |
| May 28, 1991 | 38012346M | RESOLVE | Non-Hazardous | 51#,51I,50Y,53B,73O,35#,08V,33P,73#,51# THERE IS NO OIL IN GEAR CASE 35# PROVIDE ELEV. CO. NAME. 73# PERFORM 5 YEAR T... | $75 | $0 | Nov 7, 1991 |
| May 28, 1991 | 38012347Y | RESOLVE | Non-Hazardous | 53B,73O,73#,33P,08V,73# PERFORM 5 YEAR TEST, PROPERLY TAG DEVICE, AND FILE ELV3 FORM. | $75 | $0 | Nov 7, 1991 |