1-7 Thayer Street, Manhattan
Manhattan • Block 02174 • Lot 0070 • Zip: 10040
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 6 days ago- Times Square 34 min 4 walking, 30 riding
- Penn Station 37 min 4 walking, 33 riding
- Grand Central 42 min 4 walking, 38 riding
- Union Square 47 min 4 walking, 43 riding
- Fulton Street 48 min 4 walking, 44 riding
- Downtown Brooklyn 53 min 4 walking, 49 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Bus
Citi Bike
Places nearby
G's Coffee Shop
No description yet
Asopao at Calle 191 Pescaderia
No description yet
Elsa La Reina del Chicharron
Elsa La Reina del Chicharron is a hidden gem on Broadway serving up authentic Dominican cuisine. Specializing in cris...
Cachapas Y Mas
No description yet
Krunchy Cueritos
No description yet
Gallego Seafood
No description yet
El Tesoro Grocery
No description yet
Dyckman Dogs
Dyckman Dogs is a cozy neighborhood spot offering a variety of unique hot dogs and tasty toppings. With a laid-back a...
Activity
Sales, filings, permits and violations from every dataset, in one order.
2023
-
DOB violation Jun 20, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 INTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
2021
2020
-
Alteration Type II
INTERIOR REPAIR WORK ONLY. NO CHANGE IN USE, EGRESS OR CERTIFICATE OF OCCUPANCY UNDER THIS APPLICATION.
-
Alteration Type II
TESTING & REPAIR EXISTING GAS LINE AND REPLACE EXISTING HOT WATER BOILER. NO CHANGE IN USE, EGRESS OR CERTIFICATE...
2019
-
CLASS - 2
FAILURE TO MAINTAIN FENCE.AT TIME OF INSPECTION I OBSERVED A CONSTRUCTION FENCE NOT MAINTAINED WITH SECTIONS LEAINING...
2018
-
Demolition
EMERGENCY WORK DUE TO FIRE 11/12/17, BLDGS SUSTAINED SEVERE DAMAGE. STRUCTURE WAS COMPRISED OF 6 STORES, ALONG NAGLE ...
-
DOB violation Apr 18, 2018
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
CLASS - 1
WORK W/O PERMIT.DEMO WORK W/O REQD PERMIT.A ONE STORY COMM BLD AFFECTED BY A FIRE.EMERGENCY DEMOLITION OF BLDG(I.E.D)...
2017
-
DOB violation Nov 13, 2017
C-CONSTRUCTION OTHER OPTIONAL
EMERG WRK.DUE TO FIRE 11/12/17,BLDG SUSTAIN SEVERE DAMAGE.BLDG IS COMPRISED OF 6 STORES ALONG NAGLE AVE(148,150,150,1...
-
Alteration Type II
REPLACE EXISTING HIGH PRESSURE OIL FIRED STEAM BOILER (NYC DOB BOILER NO: 45862) WITH NEW HIGH PRESSURE OIL FIRED STE...
2016
2014
-
Alteration Type III
INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. NOC HANGE IN USE, EGRESS OR OCCUPANCY.
2011
-
Alteration Type II
Renovation of store to take out restaurant. Minor partitions , plumbing fixtures , and mech hood system to be install...
2009
2008
-
CLASS - 3
FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. NOTED: STORE FRONT HAS ALUMINUM FRAME FOR GLASS AN WINDOW MISSIN...
-
CLASS - 2
STOP ALL WORK.WORK W/O PERMIT NOTED: NEW AND IMPROPER WIRING OBSERVED THROUGHOUT GROUND FLR COMMERCIAL SPACE AT 152-A...
2001
-
Non-Hazardous
16/ 49/ (1) LEFT SIDE OF THE BOILER NOT ACCESSIBLE FOR INSPECTION BOILER BE INSTALLED AS PER APPLICABLE BOLIER CODE-2...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records