Maintenance code violations
75-85 Ellwood Street, Manhattan • Block 02174 • Lot 0111
303 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Nov 13, 2019 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 1E | Dec 11, 2019 |
| Nov 13, 2019 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 1E | Dec 11, 2019 |
| Nov 13, 2019 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 1E | Dec 11, 2019 |
| Oct 31, 2019 | C | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CONCEALED WATER LEAK AT CEILIN... | 3A | Nov 8, 2019 |
| Oct 31, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR IN THE 3rd BATHRO... | 3A | Dec 5, 2019 |
| Oct 31, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILI... | 3A | Dec 5, 2019 |
| Oct 1, 2019 | C | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 2J, 2nd STORY, 1s... | 2J | Oct 22, 2019 |
| Sep 26, 2019 | C | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT BUILDING ENTRANCE , 1st STORY | — | Oct 17, 2019 |
| Jul 5, 2019 | C | DEFECT LETTER ISSUED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 4th ... | 3G | Jul 26, 2019 |
| Jul 5, 2019 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 3G | Oct 8, 2019 |
| Jul 5, 2019 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES ON FLOOR IN THE KITCHE... | 3G | Jul 13, 2019 |
| Jul 5, 2019 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 3G | Oct 8, 2019 |
| Jul 5, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN T... | 3G | Aug 9, 2019 |
| Jul 5, 2019 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFCETIVE IN THE ENTIRE APARTMENT LOCATED... | 3G | Aug 9, 2019 |
| Jul 5, 2019 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 4th STOR... | 3G | Aug 9, 2019 |
| Jul 5, 2019 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE METAL WINDOW FRAME IN THE BATHROOM LOCATED AT ... | 3G | Oct 8, 2019 |
| Jul 5, 2019 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 12 SQ FT AT METAL WINDOW FRAME A... | 3G | Aug 9, 2019 |
| Jul 5, 2019 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL IN THE BATHROO... | 3G | Oct 8, 2019 |
| Jul 5, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 4 SQ FT AT WEST WALL IN THE BATH... | 3G | Oct 8, 2019 |
| Jul 5, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NOR... | 3G | Aug 9, 2019 |
| Jul 5, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST AND SOUTH WALL... | 3G | Aug 9, 2019 |
| Jun 28, 2019 | B | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Aug 2, 2019 |
| Jun 28, 2019 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT SOUTH WALL AT PUBLIC HALL, 1... | — | Oct 1, 2019 |
| Jun 28, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOUTH WAL... | — | Aug 2, 2019 |
| Jun 28, 2019 | A | VIOLATION DISMISSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Oct 1, 2019 |
| Jun 28, 2019 | B | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Aug 2, 2019 |
| Jun 28, 2019 | B | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Aug 2, 2019 |
| Jan 3, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN TH... | 3E | Apr 8, 2019 |
| Jan 3, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT A... | 3E | Apr 8, 2019 |
| Jan 3, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 3E, 3rd S... | 3E | Apr 8, 2019 |
| Jun 18, 2018 | B | VIOLATION DISMISSED | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT ... | 3F | Jul 23, 2018 |
| Mar 13, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROVIDE METAL PAN AT MARBLE TREADS 1ST, 2ND, 3RD, 4TH, 10TH, 11TH AND 12TH UP FROM BOTTOM AT PUBLI... | — | Mar 21, 2018 |
| Mar 13, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREADS 1ST, 2ND, 3RD, 4TH, 10TH, 11TH AND 12TH UP ... | — | Mar 21, 2018 |
| Mar 13, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROVIDE METAL PAN AT MARBLE TREADS 3RD, 4TH, 10TH AND 14TH UP FROM BOTTOM AT PUBLIC HALL STAIRS , ... | — | Mar 21, 2018 |
| Mar 13, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREADS 3RD, 4TH, 10TH AND 14TH UP FROM BOTTOM AT P... | — | Mar 21, 2018 |
| Feb 12, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WASH BASIN IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY, ... | 3C | Mar 19, 2018 |
| Feb 12, 2018 | B | VIOLATION DISMISSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF AT CEILING IN THE... | 3C | Mar 19, 2018 |
| Feb 12, 2018 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING ,WALLS AND TRIM I... | 3C | May 18, 2018 |
| Feb 12, 2018 | B | VIOLATION DISMISSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY,... | 3C | Mar 19, 2018 |
| Feb 12, 2018 | B | VIOLATION DISMISSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1s... | 3C | Mar 19, 2018 |
| Feb 12, 2018 | B | VIOLATION DISMISSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK WASTE LINE IN THE KITCHEN LOCATED AT APT 3C, 3rd... | 3C | Mar 19, 2018 |
| Feb 12, 2018 | C | VIOLATION DISMISSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES NO POWER TO APT IN THE EN... | 3C | Feb 20, 2018 |
| Feb 12, 2018 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING ,WALLS AND TRIM I... | 3C | May 18, 2018 |
| Feb 12, 2018 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT A... | 3C | Mar 19, 2018 |
| Feb 12, 2018 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ... | 3C | Mar 19, 2018 |
| Dec 11, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HANDRAIL WEST WALL AT LOBBY, 1st STORY, SECTION ''NORTH'' | — | Jan 15, 2018 |
| Sep 25, 2017 | A | VIOLATION DISMISSED | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... | — | Dec 29, 2017 |
| Sep 25, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HANDRAILS AT STAIRS LEADING TO THE FRONT ENTRANCE OF THE BUILDING | — | Oct 30, 2017 |
| Sep 11, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LO... | — | Oct 16, 2017 |
| Sep 11, 2017 | A | VIOLATION DISMISSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Dec 15, 2017 |