ECB violations
30-40 Thayer Street, Manhattan • Block 02174 • Lot 0211
19 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 7, 2021 | 35477105M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE CERTIFICATE OF CORRECTION WITH DEPT OF BUILDINGS FOR VIOLATION #3... | $0 | $0 | Apr 28, 2022 |
| Aug 3, 2021 | 35409618N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:AT TIME OF INSPECTION OBSERVED ASPHALT DEBRIS APPROX 15 CUBIC Y... | $1,563 | $1,563 | Jun 2, 2022 |
| Jun 29, 2021 | 35536992P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE:AT TEIM OF INSPECTION OBSERVED AT ABOVE PREMISES ASPHALT D... | $625 | $625 | May 12, 2022 |
| Jan 21, 2021 | 35547607N | ACTIVE | CLASS - 1 | ELECTRICAL WORK WITHOUT A PERMIT.FOR THE INSTALLATION OF LIGHT FIXTURES SWITCHES OUTLET RECEPTACLES CEFICTS AND ONE N... | $800 | $800 | Apr 16, 2021 |
| May 27, 2020 | 39022835Z | RESOLVE | CLASS - 2 | GEN. CONT., OWNER OF LIC. 001177, FAILED TO POST AND DISPLAYED ACTIVE PLUMBING-GAS LINE AND METER WORK IN THE BASEMEN... | $625 | $625 | Nov 12, 2020 |
| Jun 19, 2019 | 39004415N | ACTIVE | CLASS - 1 | 2 GAS FLEX CONNECTORS CONNECTED TO SUPPLY GAS TO CLOTHES DRYER IN CELLAR. AS PER FGC 411.3.1 ONLY 1 SHALL BE USED, RE... | $625 | $0 | Feb 6, 2020 |
| Jun 19, 2019 | 35423740H | RESOLVE | CLASS - 2 | PROHIBITED USE OF ELECTRICAL METALIC TUBING(EMT). EMT RACEWAYY USED OUTDOOR FOR LIGHTING ON ROOF. REMEDY: COMPLY W/EC... | $0 | $0 | Aug 22, 2019 |
| Jun 19, 2019 | 35423741J | RESOLVE | CLASS - 2 | UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE. DEFECTIVE ... | $0 | $0 | Aug 22, 2019 |
| Jun 19, 2019 | 35423744P | RESOLVE | CLASS - 2 | FAILURE TO PROPERLY SECURE SUPPORT ELECTRICAL METALIC TUBING(EMT). EMTRACEWAY IN BASEMENT & SPLICE BOX NOT SUPPORTED.... | $0 | $0 | Aug 22, 2019 |
| Jun 19, 2019 | 35423739K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ARC FAULT CIRCUIT INTERRUPTER(AFCI)PROTECTION IN DWELLING UNITS. NO AFCI PROTECTION PROVIDED IN AP... | $1,200 | $0 | May 14, 2020 |
| Jun 19, 2019 | 39004679R | RESOLVE | CLASS - 2 | NO TPP POSTED OR DISTRIBUTED, POST OR DISTRIBUTE NOTICE OF TPP; COMPLY WITH NOTICE OF VIOLATION | $1,250 | $0 | Sep 3, 2020 |
| Jun 19, 2019 | 39004680Y | ACTIVE | CLASS - 1 | WORK WITHOUT A PERMIT, PARTITION WALLS ERECTED FROM FLOOR TO CEILING CREATING A CLASS A APARTMENT, IN BASEMENT, OBTAI... | $2,500 | $2,500 | Jan 21, 2021 |
| Jun 19, 2019 | 39004681X | RESOLVE | CLASS - 2 | NO SAFE CONSTRUCTION BILL OF RIGHTS POSTED OR DISTRIBUTED, POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS; COMPL... | $1,250 | $0 | Sep 3, 2020 |
| Jun 19, 2019 | 35423745R | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE COVER FACE PLATE LAMPHOLDER LUMINAIRE CANOPY FOR ELECTRICAL OUTLET. SPLICE BOX COVER MISSING IN BA... | $0 | $0 | Aug 22, 2019 |
| Jun 19, 2019 | 35423742L | RESOLVE | CLASS - 1 | UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE. DEFECTIVE ... | $1,600 | $0 | May 14, 2020 |
| Jun 19, 2019 | 35423738Z | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. OBSERVED AT 8:55AM ELECTRICAL FIXTURES INSTALLED IN FRONT & REAR OF BLDG ALSO APT#C25 F... | $800 | $0 | May 14, 2020 |
| Jun 19, 2019 | 35423743N | RESOLVE | CLASS - 2 | FAILURE TO PROPERLY CONNECT CONDUCTORS TO TERMINALS. ARMORED CABLES INBASEMENT NOT PROPERLY TERMINATED. REMEDY: PROVI... | $1,200 | $0 | May 14, 2020 |
| Jun 19, 2019 | 39004410Y | ACTIVE | CLASS - 1 | NEW GAS PIPING INSTALLED FROM CELLAR APARTMENT COOKING GAS METER TO CLOTHES DRYER IN CELLAR. UTILITY COMPANY CALLED T... | $2,500 | $0 | Feb 6, 2020 |
| Sep 19, 2007 | 34593699K | RESOLVE | Non-Hazardous | WORK W/O A PERMIT: CONDITIONS OBSERVED IN BASEMENT APT. 1CX A WALL APPROX. 10' LONG W/HINGED DOOR WAS ERECTED DIVIDID... | $250 | $0 | Jan 10, 2008 |