100 Arden Street, Manhattan • Block 02175 • Lot 0027
20 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 12, 2023 | 39077637X | ACTIVE | CLASS - 2 | NATCO BOILER=SAFETY VALVE DEFECTIVE/OUTSIDE FLUE TO CHIMNEY HAS TEMPORARY REPAIR/OUTSIDE CLEANOUT CAP CORRODED/SAFETY... | $625 | $0 | Mar 23, 2023 |
| Jan 12, 2023 | 39077636Y | ACTIVE | CLASS - 2 | SLANT FIN BOILER=UNREGISTERED BOILER PERMIT EXPIRED AND NO F/T PASSED INSPECTION+SIGNOFF/CO DETECTOR DEFECTIVE/LWCO D... | $655 | $0 | Mar 23, 2023 |
| Oct 16, 2019 | 35359980N | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. IN JUNE 28,,2019. TWO ELECTRICAL VIOLATIONS WAS IS... | $0 | $0 | Feb 20, 2020 |
| Jun 28, 2019 | 35359939L | RESOLVE | CLASS - 1 | FAILURE TO GROUND ELECTRICAL SYSTEMS.SIDEWALK SHED:NO GROUND CONDUCTORPROVIDED.THE SIDEWALK SHE IS NOT GROUNDED."PLEA... | $4,800 | $0 | Nov 14, 2019 |
| Jun 28, 2019 | 35359938J | RESOLVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES APPLIANCES OR WIRING IN US.OUTDOOR SIDE... | $1,600 | $0 | Nov 14, 2019 |
| Jun 20, 2019 | 35422617H | RESOLVE | CLASS - 2 | FAILURE TO NOTIFY DEPARTMENT 24 HOUR PRIOR TO SUSPENDED SCAFFOLD INSTALLATION NOTE:UPON CONDUCTING INSPECTION AT SWS ... | $1,250 | $0 | Aug 22, 2019 |
| Jun 20, 2019 | 35422616X | RESOLVE | CLASS - 2 | 3307.6.5.8:PERIODIC INSPECTION SIDEWLAK SHED NOTE AT TIME OF INSPECTION AT 6 STORY BUILDING NON ACTIVE JOB SITE I OBS... | $0 | $0 | Aug 22, 2019 |
| Mar 30, 2012 | 34944074M | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS TO JOB SITE AT TIME OF INSPECTION. NO PLANS ON SITE FOR SIDEWALK SHED. POS... | $0 | $0 | May 17, 2012 |
| Mar 30, 2012 | 34944073K | RESOLVE | CLASS - 2 | FOLLOWING THE RECEIPT OF A PERMIT TO ERECT SIDEWALK SHED THE PERMIT HOLDER SHALL POST A READILY VISIBLE SIGN ON THE S... | $0 | $0 | May 17, 2012 |
| Mar 10, 2008 | 34618933H | ACTIVE | Non-Hazardous | SEC. 27-777. FAILURE TO COMPLY W/EXHAUST LOCATION. REFERENCE STANDARD 13-2-3.4.3. NOTED: EXHAUST FAN ON 1ST EXPOSURE ... | $2,500 | $0 | Apr 9, 2009 |
| Apr 27, 2006 | 34518163M | RESOLVE | Non-Hazardous | WORK W/O PERMIT AT STORE FRONT AT BROADWAY SIDE OF BLDG RENOVATION OF STORE HAS TAKEN PLACE FULL HEIGHT WOODEN PARTIO... | $500 | $0 | Jun 15, 2006 |
| Jul 3, 2003 | 34408952H | RESOLVE | Non-Hazardous | WORK W/O A PERMIT.WORK NOTED:REMOVAL OF GYPSUM PLASTER WALLS INTERIOR ERECTING WOOD STUDS WITH 1/2" SHEET ROCK OVER S... | $0 | $0 | Aug 21, 2003 |
| May 25, 2001 | 34290931H | ACTIVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL NOTED:AT NORTH WEST CORNER-3RD FLOOR WINDOW MOUNTED AIR CONDITIONER IMPROP... | $0 | $0 | Sep 27, 2001 |
| May 21, 2001 | 34285315H | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT.WORK NOTED:REMOVAL OF INTERIOR PARTITION TO REMODULING FOR NEW COMMERCIAL SPACE LAYOUT.NO PERMI... | $0 | $0 | Jul 5, 2001 |
| May 5, 2000 | 34244300Y | RESOLVE | Non-Hazardous | WORK DOES NOT CONFORM TO APPROVED PLAN.NOTED:EXISTING STEEL SUPPORT FOR PARAPET WALL WAS ENTIRELY REMOVED PRIOR TO CO... | $130 | $0 | Aug 3, 2000 |
| May 3, 2000 | 34244299X | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT: (10% OF WORK COMPLETED) NOTED: DEMOLITION OF PARAPET WALL FROM COPING DOWN TO ROOF LEVEL ON N ... | $250 | $0 | Aug 3, 2000 |
| Jan 14, 2000 | 38093722Y | ACTIVE | Non-Hazardous | 4612,28L12. REPLACE WORN, RUSTED AND DEFECTIVE HOIST ROPES, REPLACE DEFECTIVE CWT ROLLERS. | $180 | $0 | May 4, 2000 |
| Nov 17, 1997 | 38065116X | RESOLVE | Non-Hazardous | 05J03O7302X57O74M50Y50U37U 03-REMOVE OIL FROM CAR TOP 73 #CAR SHAKING WHILE ON TRAVEL #74 PROVIDE FAN. | $0 | $0 | Jan 15, 1998 |
| Dec 31, 1992 | 34081490K | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. WORK NOTED. INSTALLED STAIRS AND MEZZANINE AT REAR OF STORE. ON 1ST FLOOR REAR. REMEDY:REMOVE ... | $0 | $0 | Feb 25, 1993 |
| Dec 15, 1992 | 38030033K | RESOLVE | Non-Hazardous | 02L,14L,17M,21L,29H,31X,50Y,50Y,57O,58O,59O,53X,73#,54M, 17-FRAME 1ST FLOOR 29-ROLLER GUIDES 31-WORKING LIGHTS 73-2 Y... | $0 | $0 | Jan 28, 1993 |