Skip to content

ECB violations

461-467 Fort Washington Avenue, Manhattan • Block 02177 • Lot 0100

27 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Apr 20, 2026 37036535L ACTIVE CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FA... $3,125 $3,125 Feb 22, 2027
Apr 21, 2025 39539323R RESOLVE CLASS - 2 AT TIME OF INSPECTION OF 6 STORY BUILDING OBSERVED OUTRIGGERS AND ILLEGAL STANDOFF BRACKETS INSTALLED WITHOUT NOTIFIC... $0 $0 Jul 24, 2025
Apr 21, 2025 39539322P RESOLVE CLASS - 2 AT TIME OF INSPECTION OF 6 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH PERMIT M00822973 EXPIRED 2-9... $1,250 $0 Jun 26, 2025
Dec 17, 2024 35689309Z ACTIVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDNG FACADE AND APPURTENANCES. NOTE: OBSERVED AT EXPOSURE 1, EAST ELEVATION CRACKED T... $1,250 $0 Mar 20, 2025
Jan 16, 2024 37026258N ACTIVE CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FA... $1,250 $0 May 16, 2024
Mar 18, 2023 39514290Z RESOLVE CLASS - 2 6 STORY BUILDING I OBSERVED SIDEWALK SHED(SWS)COMPONENTS INSTALLED AT EXP1&4. SWS AT CORNER OF EXP1,4 IS OBSTRUCTING ... $2,400 $2,400 May 25, 2023
Nov 7, 2019 39012534X RESOLVE CLASS - 2 FAILURE TO POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS. NOTE: DURING TIME OF INSPECTION, OBSERVED CONSTRUCTIO... $1,250 $0 Apr 9, 2020
Jan 28, 2019 35365358Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. *WEST ELEVATION EXP3, OBSERVED STEP CRCKS AT MASONRY ... $1,250 $0 Jun 28, 2019
Jan 28, 2019 35365359X RESOLVE CLASS - 2 REMOVAL OF SAFETY MEASURES W/O DEPT'S APPROVAL. **NOTE: AT TIME OF IN SPECTION BUILDING FACADE WAS STILL DESIGNATED A... $1,250 $0 Sep 12, 2019
Oct 15, 2018 37012791Y RESOLVE CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... $3,125 $0 May 2, 2019
Mar 21, 2017 35210443M RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEV. EXP. 1 - DEFECTIVE CORNICE - MISSING CORBELS & OTHER DOCORATIVE TRIM WIC... $500 $0 May 11, 2017
Nov 7, 2016 37001492K RESOLVE CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 1... $2,000 $0 Apr 6, 2017
Aug 11, 2016 37001105L RESOLVE CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPUR... $4,000 $0 Feb 9, 2017
Oct 26, 2015 35133765Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG REAR OF PREMISE WEST ELEV EXP#3 A/C UNIT NOIT INSTALLED BY CODE FLOWER POTS ON WIND... $1,250 $0 Dec 24, 2015
Oct 21, 2015 36023424J RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS: PERIODIC INSPECTION PF EXTERIOR WALLS... $4,000 $0 Mar 3, 2016
Aug 17, 2015 36027831P RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 6 REPORT TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DE... $800 $0 Feb 11, 2016
Sep 19, 2014 36019792L RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... $800 -$30 Apr 30, 2015
Dec 5, 2013 35024232N RESOLVE CLASS - 1 FAILURE TO TAKE REQUIRED ACTIONS TO SECURE PUBLIC SAFETY - UNSAFE FACADE NOTED: NO SAFETY MEASURES ARE ERECTED AT TIM... $2,400 $0 Feb 27, 2014
Nov 29, 2012 34985059P RESOLVE CLASS - 1 FAILURE TO TAKE AND PROVIDE SAFETY MEASURES (SIDEWALK SHED ETC)WHERE REQUIRED TO PROTECT & SECURE PUBLIC SAFETY FROM ... $0 $0 Jan 17, 2013
Jan 4, 2012 34938028K RESOLVE CLASS - 2 SEC. 28-302.5 FAILURE TO PROVIDE OVERHEAD/SHED PROTECTION TO PROTECT PUBLIC FFROM A HAZARDIOUS CONDITION. NOTED: UNSA... $800 $0 Mar 16, 2012
Mar 26, 2010 36012804H RESOLVE CLASS - 2 FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... $8,000 $0 Jul 1, 2010
Mar 6, 2007 34418312Z RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG. NORTH ELEVATION SHOWS EXTENSIVE VERTICAL CRACKS AND SEPARATING FACADE.BUDGING & DE... $800 $0 Apr 26, 2007
Aug 27, 2003 38141534K RESOLVE Non-Hazardous 2B10,15M7,8V1,10M7,53BB12,54BB12,38O2,66O2,34Q3. 2, STOP BELL NOT WORKING 34 UNDER CAR BOX. $350 $0 Dec 11, 2003
Jun 21, 2000 38098070K RESOLVE Non-Hazardous 30O2,8J1,30-CLEAN DOWN HOISTWAY,8-FL LVLS OFF IN EXCESS $2,500 $0 Aug 10, 2000
Jun 25, 1999 34146791Z RESOLVE Hazardous DIRECTED THE USE OF A SCAFFOLD WITHOUT A SPECIAL RIGGERS LICENSE. DIR-ECTED THE USE OF RIGGING EQUIPMENT WITH NO DANG... $1,750 $0 Jan 13, 2000
Jun 28, 1994 38043382L RESOLVE Non-Hazardous 14M,29M,53R,57O, 29 SPRING BUFFER 53R TEMPORARY WIRING $100 $0 Aug 25, 1994
Jun 17, 1992 38027936Y RESOLVE Non-Hazardous 11Q,28H,50Y,03M,62D,14M,3-CAPACITY PLATE 62WIRING $1,000 $0 Aug 13, 1992