Skip to content

ECB violations

570-586 West 204 Street, Manhattan • Block 02221 • Lot 0022

48 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Apr 20, 2026 39185193M ACTIVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. CLASS 1 ITEM: 1) FIRE SERVICE INOPERATIVE, REPAIR. (A17.1-2000... $1,250 $1,250 Aug 13, 2026
Apr 9, 2026 39183854L ACTIVE CLASS - 1 97-X-17 THE ONLY ELEVATOR IN THE BUILDING OUT OF SREVICE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CR... $1,250 $0 Jun 18, 2026
Sep 12, 2025 35694018P RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING FACADE WALL"S" AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION I OBSERVED AT EXP #3, ... $5,000 $0 Nov 20, 2025
Mar 27, 2025 39142979Y RESOLVE CLASS - 1 CLASS 1: DOOR ZONE RESTRICTOR WORNED. REPLACE AND TEST. $1,250 $0 Jun 5, 2025
Nov 16, 2018 35344574X ACTIVE CLASS - 3 WORK W/O A PERMIT. AT TIME OF INSPECTION OBSERVED SPACE SUBDIVIDED WITH DRYWALL PARTITION CREATING ADDITIONAL ROOM WO... $500 $0 May 16, 2019
Oct 26, 2018 35242448H RESOLVE CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C/O OR DEPARTMENT OF BUILDING RECORDS. ILLEGAL WALL ERECTED FLOOR TO CEILIN... $0 $0 Feb 7, 2019
Feb 1, 2018 35294920R RESOLVE CLASS - 1 WORK WITHOUT A PERMIT.AT THE TIME OF INSPECTION IT WAS OBSERVED THAT CONSTRUCTION WAS ONGOING IN APARTMENT 1A WITHOUA... $1,600 $0 Nov 15, 2018
Dec 10, 2013 35037742X RESOLVE CLASS - 2 WORK W/O A PERMIT.OBSERVED AT 11:50 1)100AMP PANEL & 3)6/3 RISERS IN CLOSET IN APT 3L. 1)100AMP PANEL INSTALLED IN AP... $0 $0 Jan 27, 2014
Jan 23, 2009 36007833K RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... $0 $0 Oct 8, 2009
Feb 1, 2008 38180718R RESOLVE Hazardous 31H10. 31H10-REPAIR OR REPLACE WORN CAR SHOES $0 $0 Mar 27, 2008
Jan 18, 2008 38180712X RESOLVE Hazardous 83X10, 83X10-1RCNY 11-02 RETURN ELEVATOR TO SERVICE ONLY ELEVATOR TO SERVICE BLDG HAZARDOUS CALL DOB WHEN ELEVATOR IS... $800 $0 Jun 19, 2008
Oct 19, 2007 34605690J RESOLVE Non-Hazardous TIEBACKS FOR OUT RIGGERS SECURES IN AN UNSAFE MANNER TIEBACKS SECURED IMPROPERLY TO STEPS OF ELEVATOR MACHINE ROOM AT... $4,000 $0 Apr 3, 2008
Jan 26, 2007 38162817N RESOLVE Non-Hazardous 05M11,25R7,34Q3,38O2,84X10.25-AS PER CODE.84-ONLY DEVICE IN BUILDING MAKE ALL REPAIRS AS ARE NEEDED TO RESTORE TO SER... $500 $0 Mar 22, 2007
Jan 23, 2007 38162607P RESOLVE Non-Hazardous 83X07.83-PROVIDE SERVICE TO ELEVATOR FOR INSPECTION BY THE DOB ELEVATOR DIVISION. $180 -$180 Mar 15, 2007
Jan 2, 2007 38163073Y RESOLVE Non-Hazardous 3D6/5K11/8V1/10H11/16H11/25W10/31H11/38O2/39I10/40T7/43H10/51B14/51O2/56Q3/58J1/66Z9/71K10/71Q3/84M7/84M7:3-RETURN PO... $350 $0 Mar 15, 2007
Mar 21, 2006 34512265X RESOLVE Non-Hazardous EXIT PASSAGE OR CORRIDOR: REQUIRE WIDTH DECREASE BY OBSTRUCTION. AT 3RD STORY LEVEL FIRE ESCAPE WALKWAY HAS BEEN OBST... $0 $0 Jun 22, 2006
Jun 29, 2005 38153511X RESOLVE Hazardous 66O02/38O02/08A01/20I11/14M07/15I11/21M07/84I10 66) CLEAN PIT 38) CLEAN CAR TOP 08) ADJUST LEVELING 20) 6TH FLOOR HOI... $0 $0 Sep 29, 2005
Jun 20, 2005 38153559P RESOLVE Non-Hazardous 20I11/21Q7/31H11/14M7/66O2/28Q7/3I10/38O2 20-I-11-REPLACE DAMAGED CAR VISION PANEL 21-Q-7-PROVIDE INTERLOCK COVERS ON... $0 $0 Dec 8, 2005
Apr 26, 2005 38152405H RESOLVE Non-Hazardous 05I10/16I10/08A01/14M07/15I11/51O02/52O02/59Q03/40T07/12Q03/21M07/66O02/38O02/28M07/63U07/84M07/34I10/60T07 05) CAR D... $0 $0 Jan 26, 2006
Mar 30, 2005 38151553P RESOLVE Hazardous 01X10/44B13/85U05/39I10/56M07/40M07/20I11/28M07/14M07/21M07/66O02.CEASE USE.(01-X-10)REPAIR STOP SWITCH.(44-B-13) PRO... $0 $0 May 19, 2005
Oct 19, 2004 38149671N RESOLVE Non-Hazardous 01B01/ 16B01/ 21M07/ 28M07/ 34B10/ 71M07/ 71B10/ 66O02/ 01=ADJUST STOPSWITCH SO SWITCH STAYS MADE WHEN PUSHED FOR ALA... $350 $0 May 5, 2005
Sep 10, 2003 38142075P RESOLVE Non-Hazardous 25D06/15I11/39Q07/63#07/60T07/28Q07/34Q07/38O02/31H10/66O02/77B14 15-POST CERT.AS PER 27-1004A OR 27-1004B,39 PROVIDE... $350 $0 Oct 14, 2004
Dec 23, 2002 34372673N RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING (HAZARDOUS) NOTED INAPT 1C THERE ARE DEFECTIVE FLOOR SUPPORTS CAUSING A SIGNIFICAT DROP ... $800 $0 Oct 14, 2004
May 31, 2002 34316138P RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING NOTED A SECTION OF GYPSUM PLASTER APPROX 24"X24"DROPPED FROM THE CEILING OF APT 1F REMED... $0 $0 Dec 12, 2002
Jun 26, 2001 38117391M RESOLVE Non-Hazardous 14M07-35D11-17B12 14-INSTALL CERT. FRAME WITH CERT OR LOCATION SIGN 35-REPAIR MOTOR ROOM STAIRS, INSTALL HANDRAIL,REP... $0 $0 Aug 16, 2001
Jul 27, 2000 32019108K RESOLVE Hazardous 49A CARBON BUILDUP IN IN FRONT OF BURNER 49B FLU NOT SEALED 49C NO RELIEF VALVE ON TANKLESS COIL 49D WRONG SIZE BACKF... $400 $0 Mar 1, 2001
Feb 24, 2000 38094861Z RESOLVE Non-Hazardous 08V01/05J11/23U16/3502/51B7/73U16 - 73U16=INCORRECT CITY I.D. #CORRECT NUMBER IS 1P6738 $0 $0 Dec 6, 2001
Jun 9, 1999 34212280J RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR. DEFECT IS: ENTIRE REAR RETAINING RUBBLESTONE WALL IS DEFECTIVE IN THAT ROTTED MORTAR JO... $0 $0 Jul 29, 1999
Apr 26, 1999 38086810Z RESOLVE Non-Hazardous 14M 15J 17M 30P 35I 38Q 50Y 57P 73O 14 PROVIDE 15 ADJUST 17 GLASS ON HOISTWAY CAR DOOR 30 PROVIDE 35 STAIR TO MOTOR R... $180 $0 Jul 16, 1999
Jul 23, 1998 38075264R RESOLVE Non-Hazardous 35B07, 50Y14, 52I12, 37Q03, 17I12, 14I12, 73O02, 55M07, 28H11, 53B07, 35B-PROVIDE HANDRAILS FORSTEDS. 52I-OIL SOKED B... $0 $0 Oct 8, 1998
Dec 2, 1997 34168634M RESOLVE Non-Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY #12802 IN THAT 1ST FLOOR CONVERTED FROM: APT. TO: ... $800 $0 May 7, 1998
Nov 18, 1997 34166857K RESOLVE Non-Hazardous WORK WITHOUT A PERMIT. WORK NOTED: REMOVED EXISTING WINDOWS ON 1ST FLOOR APARTMENT AT SOUTH EAST SIDE OF BUILDING AND... $0 $0 Jan 15, 1998
Oct 21, 1997 34166533Y RESOLVE Non-Hazardous WORK WITHOUT A PERMIT. WORK NOTED: SEALED BASEMENT WINDOWS WITH CEMENTBLOCKS AT SOUTHEAST CORNER OF BLDG. CREATED DOO... $350 $0 Dec 11, 1997
Oct 21, 1997 34166534X RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL. DEFECT IS: ENTIRE REAR FOUNDATION RUBBLE STONE WALL DEFECTIVE IN THAT ROTTED ... $800 $0 Jan 29, 1998
Mar 5, 1996 38055185K RESOLVE Hazardous 08V,15L,28H,31Q,35Y,18M,17M,40J,41X,46H,50Y,50Y,52L,57O.15L HANGING ONTHE FLR.35Y FLR.18MCOVER(BASMT)17M CAR DOOR.40J... $1,250 $0 Jun 6, 1996
Aug 30, 1995 34128793N RESOLVE Non-Hazardous WORK WITHOUT A PERMIT WORK NOTED REMOVE WINDOEW IN BASEMENT AT SOUTH SIDE OF BLDG AND BLOCKED WITH 8" CONCRETE BLOCKS... $0 $0 Dec 14, 1995
May 24, 1995 38050092Z RESOLVE Non-Hazardous 31Q, 35P, 57O, 11Q, 18Q, 703. $100 $0 Sep 7, 1995
Mar 10, 1995 34124114Y RESOLVE Non-Hazardous WORK WITHOUT A PERMIT. WORKED NOTED: EXISTING WINDOW REMOVED BLOCKEDUP WITH 8" CEMENT BLOCKS ALSO MADE NEW DOORWAY 8'... $350 $0 Jul 6, 1995
Sep 21, 1994 38044268M RESOLVE Non-Hazardous 8V,5I,15L,18L,25L,31Q,35P,57O,63L,74# 5I-ROTTEN AT BOTTOM 15L-HANGING (HITTING) THE FLOOR AND DOOR 18L- HITTING ROLLE... $0 $0 Nov 17, 1994
Nov 23, 1993 38038347J RESOLVE Non-Hazardous 14M,31Q,53X,74X,35P,35I,54#,3#. 14 CARD. 74 WORK LIGHT. 54 INSTALL NEW WIRE WITHOUT PERMIT. 3 EXCESS SIDE PLAY $0 $0 Feb 4, 1994
Feb 18, 1993 38030947R RESOLVE Non-Hazardous 35P,33P,57O,03I,17I. $0 $0 Apr 22, 1993
Jan 26, 1993 34081496L RESOLVE Non-Hazardous WORK WITHOUT A PERMIT. WORK NOTED: REMOVED EXISTING WINDOWS ON 1ST FLRAPARTMENT AT SOUTH EAST SIDE OF BUILDING AND BL... $350 $0 Apr 22, 1993
May 11, 1992 38026112R RESOLVE Non-Hazardous 50Y,73O,8V,14M,73#,61K,3M,40H,27R,46K,46Q,50F,25Q,17I,31Q,53X,37Q,35I,34#, 73- PERFORM 5 YR TEST-TAG DEVICE AND FILE ... $75 $0 Aug 14, 1992
Aug 15, 1991 34061506H RESOLVE Non-Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICIATE OF OOCCUPANCY CERTIFICATE OR OCCUPANCY NO#12802.THERE IS A DEL... $0 $0 Jan 2, 1992
Aug 14, 1991 38015743J RESOLVE Non-Hazardous 73#,13M,50Y,73O,22D,08V,14M,33P. 73#PERFORM 5YEAR TEST PROPERLY TAG DEVICE AND FILE ELV. 3 FORM. $0 $0 Nov 14, 1991
Aug 12, 1991 38013741R RESOLVE Non-Hazardous 35P,22W,11Q,57O,30O,73#,15I,73# PERFORM 5 YEAR TEST AND FILE TAG GOVERNOR. 15-I PUSH PLATES MISSING ON HATCH DOORS. $150 $0 Oct 10, 1991
May 1, 1991 34052415H RESOLVE Non-Hazardous WORK WITHOUT A PERMIT NOTED:1)SEALED WINDOWS AT 1ST FL WITH MASONARY BLOCK AT REAR 2)PENETRATION OF WINDOW LINE CREAT... $285 $0 Sep 19, 1991
Nov 3, 1989 34032729M RESOLVE Non-Hazardous WORK WITHOUT A PERMIT WORK NOTED REMOVED EXISTING WINDOWS ON 1 FLOOR APT AT SOUTH EAST SIDE OF BUILDING AND BLOCKED U... $1,000 $0 Dec 14, 1989