| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 14, 2018 | 35337730N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION# 35250007M ISSUED ON 2/12/18 & TO FILE A... | $1,250 | $0 | Jun 28, 2018 |
| Apr 5, 2018 | 35325583Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35250007M ISSUED 02/12/18 AND TO FILE ... | $1,250 | $0 | Aug 9, 2018 |
| Feb 12, 2018 | 35250007M | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY #86880 IN THAT COFO INDICATES COMMUNITY ROOM BOILER RO... | $1,200 | $0 | Aug 9, 2018 |
| Jan 19, 2017 | 38252701K | RESOLVE | CLASS - 2 | 5X10,59BB15,68B1. 5-DOOR ZONE RESTRICTOR INOPERATIVE; 59-EXPIRED BRAKE MAINTENANCE TAG A17.1 2003 8.6.4.6; 68-MAINTEN... | $0 | $0 | Mar 9, 2017 |
| Jun 8, 2016 | 38243143K | RESOLVE | CLASS - 1 | 97X10 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER; SERVICE EQUIPMENT-ELEVATOR AS PER BC 3001 AND 27-987.DOB... | $1,000 | $0 | Jul 28, 2016 |
| Feb 7, 2011 | 34879566K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG WALL DEFECT IS SPALLING CRACKED AND MISSING AMENT STUCCO ABOVE FIFTH STORY WINDOW A... | $250 | $0 | Mar 24, 2011 |
| Dec 28, 2009 | 32067825J | RESOLVE | CLASS - 2 | 15 34 50A-CHECK VALVE REQUIRED BTWN BACK FLOW PREVENTER AND PRESSURE REDUCING VALVE | $2,500 | $0 | Feb 18, 2010 |
| Dec 28, 2009 | 32067423R | RESOLVE | CLASS - 2 | 15 34 50A-CHECK VALVE REQUIRED BTWN BACK FLOW PREVENTER AND PRESSURE REDUCING VALUE | $0 | $0 | Feb 18, 2010 |
| Dec 28, 2009 | 32067424Z | RESOLVE | CLASS - 2 | 50A-CHECK VALVE REQUIRED BTWN BACK FLOW PREVENTER AND PRESSURE REDUCING VALVE 15 34 | $0 | $0 | Feb 18, 2010 |
| Dec 28, 2009 | 34816793M | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BLDG WALL OR APPURTANANCE. DEFECT NOTED: NORTH WALL EXTERIOR WALL OF BATHROOM A CRACK ON WALL X-3... | $200 | $0 | Feb 18, 2010 |
| Dec 28, 2009 | 32067422P | RESOLVE | CLASS - 1 | B101 WORK WITHOUT A PERMIT | $0 | $0 | Oct 19, 2011 |
| Sep 21, 2009 | 38206279R | RESOLVE | CLASS - 2 | 17H11.17D6.53B14.05I10. 17H REPLACE WHERE NEEDED 17D SECURE AT 1ST FL 53B SHORTENS 61P REMOVE PADLOCK 42G UNREADABLE ... | $0 | $0 | Sep 9, 2010 |
| Feb 13, 2008 | 38181924M | RESOLVE | Non-Hazardous | 58B01,05J01,10H11,66O02,52H11,17H11,65B01.65B01-PUT STOP SWITCH IS 58"OF BOTTOM LANDING SADDLE."RE POSITION STOP SW 1... | $350 | $0 | Jun 27, 2008 |
| Jan 7, 2002 | 38120564Z | RESOLVE | Non-Hazardous | 5J11/ 16H12/ 23U16/ 46B15/ 53B7/ 57O2/ 57Z9/ 5J11 = TOO MUCH GAP TO CAR POST 16H12 = 1 & 3RD FLS | $2,500 | $0 | Feb 21, 2002 |
| Sep 9, 2000 | 38096518K | RESOLVE | Non-Hazardous | 75U05,35P17.75-5 YR TEST.35-PROVIDE ACCESS. | $2,500 | $0 | Oct 26, 2000 |
| Jan 5, 1996 | 38054130Z | RESOLVE | Non-Hazardous | 54R,21X,53X. 54 WIRING TO ELEV LIGHT INSTALL AS PER CODE. | $200 | $0 | May 9, 1996 |
| May 31, 1995 | 38049409J | RESOLVE | Non-Hazardous | 54R. 54-LIGHT IN ELEVATOR AND WIRE AS PER CODE. | $0 | $0 | Dec 14, 1995 |
| Sep 12, 1994 | 38044178Z | RESOLVE | Non-Hazardous | 46K,37G,57O | $200 | $0 | Mar 16, 1995 |
| May 18, 1992 | 38025777R | RESOLVE | Non-Hazardous | 03X,46L,33X,54M,73#,03-DIRECTIONAL CONTORUS 54-ELEVATOR CO.NAME 73-PERFORM 5YR TEST,PROPERLY TAG DEVICE ,AND FILE ELV... | $1,000 | $0 | Jul 2, 1992 |
| Dec 16, 1991 | 38019593L | RESOLVE | Non-Hazardous | 46I,35P,73O,22D,74X, 46 SHACKLE SPRINGS 74 HAVE ELEV ANS. ALL VCALL SOTHAT A PROPER INSPECTION CAN BE MADE BY THIS DEPT. | $0 | $0 | Aug 6, 1992 |