ECB violations
100-102 Park Terrace West, Manhattan • Block 02243 • Lot 0289
20 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 8, 2025 | 37034732L | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $2,500 | $2,500 | Jul 3, 2025 |
| Feb 7, 2025 | 39137774Y | ACTIVE | CLASS - 2 | I OBSERVED ON STREET LEVEL OF BUILDING GAS PIPING AND FITTINGS INSTALLED FOR SEVERAL COMMERCIAL GAS DRYERS AND NO PER... | $1,250 | $0 | Apr 17, 2025 |
| Feb 7, 2025 | 39137775X | ACTIVE | CLASS - 3 | I OBSERVED AN LAUNDRY ROOM IN BUILDING WHICH IS CONTRARY OF C OF O ON FILE AT TIME OF INSPECTION, DISCONTINUE ILLEGAL... | $500 | $500 | Apr 17, 2025 |
| Feb 7, 2025 | 39137776H | ACTIVE | CLASS - 2 | I OBSERVED ON STREET LEVEL SEVERAL COMMERCIAL GAS DRYERS AND NO SPRINKLER SYSTEM NEAR AND/OR AROUND ARE WHICH IS NOT ... | $1,250 | $0 | Apr 17, 2025 |
| Jun 28, 2022 | 39502758R | RESOLVE | CLASS - 2 | EXPIRED PERMIT 6-18-2022 M00597784RENEW PERMIT | $625 | $0 | Aug 18, 2022 |
| Mar 7, 2018 | 37009250Y | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... | $3,125 | -$3,125 | May 24, 2018 |
| Apr 18, 2017 | 35253706P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING.ROOF-CHIPPED COPING - BOILER CHIMNEY STEP CRACK-STAIR B BULKHEAD AT ROOF MISSIN... | $2,500 | $0 | Jun 8, 2017 |
| Dec 7, 2015 | 36023846J | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE WITH CODEPROVISIONS: PERIODIC INSPECTION OF EXTERIOR WAL... | $2,000 | -$2,000 | Apr 7, 2016 |
| Jan 5, 2015 | 36026982H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $2,000 | -$2,000 | May 7, 2015 |
| Apr 8, 2009 | 34764837N | RESOLVE | CLASS - 2 | FAILED TO NOTIFY DEPT/OBTAIN PERMIT PRIOR TO USE/INSTALL C HOOKS IN CONNECTION W/ SUSPENDED SCAFFOLD. NOTED: C HOOKS ... | $400 | $0 | Jun 16, 2009 |
| Apr 8, 2009 | 34764836L | RESOLVE | CLASS - 2 | SIDEWALK DOES NOT MEET CODE SPECIFICATIONS. NOTED: LARGE GAPE THROUGHOUT ALONG EXP 1,3& 4 (FRONT N SIDE AND S SIDE) A... | $0 | $0 | May 28, 2009 |
| Mar 25, 2009 | 34764653Z | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURES OPERATION OF HOISTING EQUIPMENT IN AN UNSAFE MANNER. MISSING FIST GRIPS. LIFE LINE & TIE B... | $4,800 | $0 | Feb 4, 2010 |
| Nov 7, 2008 | 34709996Z | RESOLVE | CLASS - 2 | LICENSE RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MIN. REQUIREMENTS (NO CRT OF FITNESS) REMEDY:COMPLY W/ CODE | $4,000 | $0 | Jan 8, 2009 |
| Nov 7, 2008 | 34709994P | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. HOIST IS MISSING COUNTERWEIGHTS.... | $250 | $0 | Jul 2, 2009 |
| Nov 7, 2008 | 34709995R | RESOLVE | CLASS - 1 | NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD PERFORMED BY AUTHORIZED PERSON AT SITE REMEDY:MAINTAIN DAILY INSP... | $2,400 | $0 | Jul 2, 2009 |
| Sep 12, 2007 | 38169522H | RESOLVE | Non-Hazardous | 40T07,59Q03,85BB05,86BB05.40T07-PROVIDE SIGN FOR MOTOR ROOM DOOR 8. | $0 | $0 | Nov 8, 2007 |
| Jun 5, 2000 | 34248782Y | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT. PURSUANT TO RULE R.C.N.Y. 32-03B(5),INDICTING C... | $400 | $0 | Aug 10, 2000 |
| Sep 4, 1996 | 34119202H | ACTIVE | Hazardous | USE OF RIGGING EQUIPMENT(SCAFFOLD)WITHOUT A SPECIAL RIGGERS LICENSE. USE OF RIGGING EQUIPMENT(SCAFFOLD)WITHOUT ANY DA... | $1,000 | $0 | Oct 24, 1996 |
| Jun 9, 1995 | 38049425J | ACTIVE | Non-Hazardous | 3#. 3 OPENING FOR TOP EMERGENCY EXIT INSIDE AS PER CODE. | $100 | $0 | Aug 24, 1995 |