Skip to content

ECB violations

133 Brown Place, Bronx • Block 02278 • Lot 0053

29 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
May 22, 2020 35490443L RESOLVE CLASS - 1 PROVISION OF LAW:BC3303.9.FAILURE TO MAINTAIN EGRESS(CLEAR&OBSTRUCTED)AND OTHER ELEMENTS DURING CONSTRUCTION OPERATIO... $2,500 $0 Apr 23, 2021
May 19, 2020 35491720P RESOLVE CLASS - 1 FAILURE TO PROVIDE ADEQUATE WORK PLATFORM NOTE AT TIME OF MY INSPECTION OF A 6 STORY BUILDING AT ROOF LEVEL CONSTRUCT... $2,500 $0 Apr 23, 2021
May 19, 2020 35491721R RESOLVE CLASS - 2 FAILURE TO MAINATINA DEQUATE HOUSEKEEPING AT TIME OF INSPECTION OF A 6S TORY NEW BUILDING TOP OFF AT ROOF LEVEL I NOT... $0 $0 Jul 17, 2020
Mar 11, 2020 35471005H RESOLVE CLASS - 1 CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE(CORRECTING UNSAFE CONDITIONS).AT THE TIME OF INSPECTION... $2,500 $0 Jan 28, 2022
Mar 11, 2020 35471008N RESOLVE CLASS - 2 FAILED TO NOTIFY DEPT PRIOR TO INSTALLATION OR REMOVAL OF SUSPENDED SCAFFOLD.AT THE TIME OF INSPECTION I OBSERVED 6ST... $1,250 $0 Jan 28, 2022
Mar 11, 2020 35471007L RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVAL CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS(SSP)AT TIME OF INSPECTION I OBSERVED... $625 $0 Jan 28, 2022
Mar 11, 2020 35471004X RESOLVE CLASS - 1 FAILURE TO MAINTAIN INSTITUTE SAFETY MEASURES.AT THE TIME OF INSPECTION I OBSERVED 6 STORY NEW BLDG COMPLETE TO ROOF ... $10,000 $0 Jun 24, 2022
Mar 11, 2020 35471006J RESOLVE CLASS - 1 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY CHAPTER 33. AT THE TIME OF INSPECTION I OBSERVED 6 STORY NE... $625 $0 Jan 28, 2022
Mar 2, 2020 35479130N RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR AMENDMENTS-PIPE SCAFFOLD PLANS AT THE TIME OF INSPECT... $2,500 $0 Sep 4, 2020
Dec 5, 2019 35464551J RESOLVE CLASS - 2 BC330161-NO DESIGN DRAWING FOR TEMPORARY PLATFORM AT ELEVATOR STAFF.ATTIME OF INSPECITON I OBSERVED AN ACTIVE CONSTRU... $0 $0 Jan 31, 2020
Dec 5, 2019 35411904R RESOLVE CLASS - 1 BC2205.6.2/FIELD CONNECTION FIELD CONNECTION SHALL MEET THE REQUIRMENTS FOR CORRESEPONDIGN TYPES OF SHOP CONNECTIONS ... $2,500 $0 Mar 13, 2020
Dec 5, 2019 35464550H RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION DOCUMENTS AT JOBSITEAT TIME OF INSPECTOIN.AT TIME FO INSPECTOIN I O... $0 $0 Jan 31, 2020
Dec 5, 2019 35464552L RESOLVE CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPINGPER SECTION REQUIRED.AT TIME OF INSPECITON I OBSERVE AN ACTIVE CONSTRUCTION ... $0 $0 Jan 31, 2020
Nov 25, 2019 35464212P RESOLVE CLASS - 1 FAILURE TO COMPLY WITH AN ORDER TO STOP WORK BY DEPARTMENT.AT TIME OF INSPECTION I OBSERVED AN ACTIVE CONSTRUCTION WI... $0 $0 Jan 17, 2020
Nov 23, 2019 35464211N RESOLVE CLASS - 1 BC.3301.1.3 MANUFACTURER SPECIFICATIONS.AT TIME OF INSPECTION I OBSERVED AN CONSTRUCTION SITE WAS PERFORMED.FRAMING W... $0 $0 Jan 17, 2020
Nov 23, 2019 35464208M RESOLVE CLASS - 1 3301.2NO OVERHEAD PROTECTION.@TIME OF INSPECTION I OBSERVED A CONSTRU CTION SITE WAS PERFORM.FRAMING WORK WAS IN PROG... $0 $0 Jan 17, 2020
Nov 23, 2019 35464209Y RESOLVE CLASS - 1 BC.3307.4.7 WORK OR STORAGE ZONES.AT TIME OF INSPECTION I OBSERVED AN CONSTRUCTION SITE WAS PERFORM FRAMING WORK WAS ... $2,500 $0 Jan 17, 2020
Nov 23, 2019 35464210L RESOLVE CLASS - 2 INADEQUATE FENCE. AT THE TIME OF INSPECTION I OBSERVED AND CONSTRUCTION SITE WITH FRAMING WORK WAS IN PROGRESS,DURING... $0 $0 Jan 17, 2020
May 22, 2019 35431902L RESOLVE CLASS - 2 BX3301.13.13.LOGS.NOTE:AT TIME OF INSPECTION OF NB 6 STORY BUILDING WORK IN PROGRESS UPON REQUEST OR CONSTRUCTION SUP... $0 $0 Jul 19, 2019
May 22, 2019 35431904P RESOLVE CLASS - 1 SITE SAFETY PLANS.NOTE:AT TIME OF INSPECTION OF NEW BUILDING WORK IN PROGRESS OF FOUNDATION PHASE UPON REQUEST FOR SS... $625 $0 Aug 13, 2021
May 22, 2019 35431903N RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOBSITE AT TIME OF INSPECITON.NOTE:AT TIME OF INSPECTION OF A NEW BUILD... $0 $0 Jul 19, 2019
May 22, 2019 35431901J RESOLVE CLASS - 1 FAILURE TO DESIGNATE AND OR HAVE CONSTRUCTION SUPERINTENDENT PRESENT AT SITE.NOTE:AT TIME OF INSPECITON OF A SIX STOR... $0 $0 Aug 13, 2021
May 22, 2019 35431900H RESOLVE CLASS - 1 CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER CODE.AT TIME OF INSPECITON I OBSERVED THAT THE REGISTERED... $2,500 $0 Aug 13, 2021
Mar 28, 2019 35369199Y RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AMENDMENTS AND/OR APPROVED AMENDMENTS: AS NOTED @TIME OF INS... $0 $0 May 17, 2019
May 7, 2018 35314115J RESOLVE CLASS - 2 BC 107.8;BC 107.7.3 DEFICIENT DRAWINGS-THE RESPONDENT,DESIGN APPLICANT.FAILED TO MEET THE REQ OF BC 107.8 & BC 107.7.... $625 $0 Sep 7, 2018
Mar 27, 2018 35314410M RESOLVE CLASS - 1 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33 "SSP". AT TIME OF INSPECTION OBSERVED AN ACTI... $625 $0 Aug 10, 2018
Mar 27, 2018 35314409P RESOLVE CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION.ATTIME OF INSPECTION OBSEVED AN ACTIVE CONSTRUCTI... $0 $0 May 18, 2018
Mar 27, 2018 35314408N RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION DOCUMENTS AT JOB SITE AT TIME OF INSPECTION. AT TIME OF INSPECTION ... $0 $0 May 18, 2018
Mar 27, 2018 35314411Y RESOLVE CLASS - 1 CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE. AT TIMEOF INSPECTION OBSERVED AN ACTIVE CONSTRUCTION S... $10,000 $0 Aug 10, 2018