Skip to content

ECB violations

109 Bruckner Boulevard, Bronx • Block 02278 • Lot 0059

20 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jan 6, 2025 39134648J RESOLVE CLASS - 1 CLASS 1 ITEM: INOPERATIVE AND MISALIGNED DISC BRAKE MONITOR. PARAMETER SET TO ZERO. CLASS 2 ITEMS: TOP LANDING IS AN ... $0 $0 Oct 28, 2025
Jun 17, 2020 35471674P RESOLVE CLASS - 2 SEC. BC 3303.11 FAILURE TO MAINTAIN EGRESS. AT TIME OF INSPECTION OBSERVED AN ACTIVE CONSTRUCTION SITE W/INTERIOR WOR... $0 $0 Jan 8, 2021
Jun 17, 2020 35471673N RESOLVE CLASS - 1 SEC. BC 3307.6.2 FAILURE TO PROVIDE SIDEWALK SHED EXTENSION. AT TIME OF INSPECTION OBSERVED AN ACTIVE CONSTRUCTION SI... $0 $0 Nov 20, 2020
Jun 17, 2020 35471672L RESOLVE CLASS - 2 INADEQUATE SITE SAFETY PLANS. AT TIME OF INSPECTION OBSERVED AN ACTIVECONSTRUCTION SITE W/INTERIOR WORK IN PROGRESS @... $0 $0 May 21, 2021
Jun 2, 2020 35492446X RESOLVE CLASS - 2 DOCUMENTS TO BE KEPT ON SITE(AMENDED WORK PLATFOMR)AT THE TIME OF MY INSPECTION,I OBSERVED THAT THE TEMPORARY WORK PL... $0 $0 Jul 31, 2020
Apr 29, 2020 35490107M RESOLVE CLASS - 1 SEC. 3309.10 PROTECTION OF ROOFS. AT THE TIME OF MY INSPECTION,I OBSERVED THAT THE ROOF PROTECTION AT THE ADJOINING P... $2,500 $0 Aug 13, 2021
Apr 29, 2020 35490108Y RESOLVE CLASS - 1 SEC. 3314.1 SCAFFOLDS. AT THE TIME OF MY INSPECTION,I OBSERVED A MISSING CROSS-BRACE CONNECTION & SEVERAL CUT SUPPORT... $2,500 $0 Feb 5, 2021
Mar 3, 2020 39018749K RESOLVE CLASS - 2 AT THE TIME OF ENERGY CODE INSPECTION, I OBSERVED ALL WINDOWS ON EXPOSURES 1, & 3, W/ UF-0.29 OPERABLE, AND UF-0.28 F... $1,000 $0 Nov 13, 2020
Jan 29, 2020 39016506R RESOLVE CLASS - 2 AT THE TIME OF ENERGY CODE INSPECTION, I OBSERVED THAT THE INSULATION PLACEMENT AND/OR R-VALUES DO NOT MEET THE MINIM... $0 $0 Sep 10, 2021
Jan 16, 2020 35456991N RESOLVE CLASS - 1 3307.6.3 AREA TO BE PROTECTED-SIDEWALK SHED EXTENSION.UPON INSP OF A 6STORY NB I OBSERVED-SITE CLOSED-I ALSO OBSERVED... $1,200 $0 Apr 22, 2021
Oct 28, 2019 35461828J RESOLVE CLASS - 1 INADEQUATE HANDRAILS-AT TIME OF INSPECTION ON AN ACTIVE JOBSITE OF A 6STORY BUILDING UNDER CONSTRUCTION,OBSERVED INAD... $2,500 $0 Jan 14, 2022
Oct 28, 2019 35461831K RESOLVE CLASS - 1 INADEQUATE GUARDRAILS-AT TIME OF INSPECTION ON AN ACTIVE JOBSITE OF A 6 STORY NB,OBSERVED GUARDRAILS AT VARIOUS LOCAT... $0 $0 Jan 14, 2022
Oct 28, 2019 35461829L RESOLVE CLASS - 1 FAILED TO MAINTAIN ON-SITE DOCUMENTS,AS REQUIRED. AT TIME OF INSPECTION ON AN ACTIVE SITE OF A 6-STORY NB,I OBSERVED ... $0 $0 Jan 14, 2022
Oct 28, 2019 35461830Z RESOLVE CLASS - 1 3305.2 STRUCTURAL STEEL ASSEMBLY/FABRICATION. AT TIME OF INSPECTION ONAN ACTIVE JOBSITE,OBSERVED STEEL ASSEMBLY,CONNE... $0 $0 Jan 14, 2022
Oct 28, 2019 35461827H RESOLVE CLASS - 1 3307.6.3 MISSING SWS-AT TIME OF INSPECTION ON AN ACTIVE JOBSITE,I OBSERVED THAT THE SWS DIDN'T EXTEND AT THE ADJACENT... $2,500 $0 Jan 14, 2022
Sep 20, 2019 35449872P RESOLVE CLASS - 1 CB1704.1.MISSING SIGNATURES ON TRI+INITIALS. AT TIME OF INSPECTION ON A PROPOSED 6-STORY BUILDING CURRENTLY A 4TH FLO... $2,500 $0 Nov 22, 2019
May 22, 2019 35431907K RESOLVE CLASS - 1 FAILURE TO DESIGNATE AND OR HAVE CONSTRUCTION SUPERINTENDENT PRESENT AT SITE.NOTE:AT TIME OF INSPECITON OF A 6 STORY ... $0 $0 Aug 13, 2021
May 22, 2019 35431908M RESOLVE CLASS - 1 SITE SAFETY PLANS.NOTE:AT TIME OF INSPECTION OF A NEW BUILDING WORK INPROGRESS OF EXCAVATION PHASE UPON REQUEST FOR S... $312 $0 Sep 25, 2020
May 22, 2019 35431905R RESOLVE CLASS - 1 $0 $0 Aug 13, 2021
Jan 16, 2019 35384826J RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION DOCUMENTS AT JOBSITEAT TIME OF INSPECTION. AT THE TIME OF INSPECTIO... $313 $0 Jul 12, 2019