ECB violations
325 East 132 Street, Bronx • Block 02295 • Lot 0051
32 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 21, 2023 | 39514428M | RESOLVE | CLASS - 1 | IN RESPONSE TO INCIDENT THAT HAPPENED ON 3-20-23 WHERE WORKER FELL OFF 1ST RUNG OF 6 FOOT A FRAME LADDER WHILE INSTAL... | $0 | $0 | Nov 21, 2024 |
| Mar 10, 2023 | 39514020Z | RESOLVE | CLASS - 1 | AT TIME OF A INCIDENT OF A WORKER FALLING FROM A 8 FOOT A-FRAME LADDER INSTALLING 3" WIRING UP TO CEILING HEIGHT OF A... | $2,500 | $0 | Jun 6, 2024 |
| Mar 8, 2023 | 39513905L | RESOLVE | CLASS - 2 | INADEQUATE CONTENT : AT THE TIME OF INSPECTION AS PER SSM, AT 6TH FLOOR, CLEANING WORKER CARING 2 GARBAGE BAGS, TRIPP... | $1,250 | $0 | Sep 17, 2024 |
| Feb 24, 2023 | 35653947Z | RESOLVE | CLASS - 1 | FAILED TO NOTIFY THE DEPT OF AN INCIDENT THAT RESULTED IN A FATALITY OR INJURY.NOTE A WORKER SLIPPED OFF THE SECOND S... | $5,000 | $0 | Apr 11, 2024 |
| Feb 23, 2023 | 39513490Z | RESOLVE | CLASS - 1 | FAILURE TO CONFORM TO CODE FOR HORIZONTAL-ALTERNATIVE SUPPORTED SCAFFOLD. THE SUPPORTED SCAFFOLD MAY BE UTILIZED AND ... | $625 | $0 | Oct 19, 2023 |
| Feb 23, 2023 | 39513491K | RESOLVE | CLASS - 2 | SSP DOESN'T CONFORM TO FIELD CONDITIONS. PLATFORMS FOR GARBAGE REMOVAL ARE NOT ON SSP.AMEND SSP | $625 | $0 | Oct 19, 2023 |
| Jan 24, 2023 | 39512143J | RESOLVE | CLASS - 1 | EXISTING CONDITION DOES NOT CONFORM TO SITE SAFETY PLAN.ON FOLLOW UP INSPECTION WHERE WORKER GOT INJURED I OBSERVED A... | $0 | $0 | Feb 20, 2024 |
| Dec 16, 2022 | 39510440R | RESOLVE | CLASS - 2 | RESPONDING TO INCIDENT WHERE WORKER WAS HIT BY FALLING FORM WORK. INSPECTION REVEALED THAT WORKER WAS PERFORMING STRI... | $0 | $0 | Jun 17, 2025 |
| Apr 15, 2022 | 35645507P | RESOLVE | CLASS - 1 | CONST SUPER FAILED TO IMMEDIATELY NOTIFY DEPT OF CONDITIONS AS REQUIRED ATO MY INSP OF INCIDENT OF GASLINE MAIN THAT ... | $625 | $0 | Apr 21, 2023 |
| Apr 15, 2022 | 35645506N | RESOLVE | CLASS - 1 | FAILURE TO PROMPTLY NOTIFY DEPT OF ACCIDENT.ATO MY INSP OF RUPTURED GAS MAIN INSIDE 3STY DEMO JOBSITE@GRND LEVEL.DEMO... | $0 | $0 | Jun 27, 2024 |
| Apr 15, 2022 | 35645505L | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS&PROPERTY AFFECTED BY CONST OPS.ATO MYINSP OF INCIDENT IN REGARDS OF GASLINE MAIN THA... | $0 | $0 | Jun 27, 2024 |
| Feb 15, 2022 | 35636753X | RESOLVE | CLASS - 2 | CONSTRUCTION SUPER FAILED TO PERFORM DUTIES PER CODE.NOTE:RALPH J.SCOPO MERGED 4 DEMO JOBS(220736256/220736265/220736... | $2,500 | $0 | Jul 19, 2023 |
| Feb 9, 2022 | 35639935K | RESOLVE | CLASS - 1 | FAILURE TO CARRY OUT DEMO OP AS REQUIRED BY SEC.ATO MY INSP I OBSERVED3STYB UNDERGOING FULL DEMO.I NOTICED THAT SEQUE... | $2,500 | $2,500 | Jan 4, 2024 |
| Feb 9, 2022 | 35639933R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE REQUIRED NOTIFICATION PRIOR TO COMMENCEMENT OF DEMO.ATO MY INSP I NOTICED 3STYB BEING DEMO.UPON RE... | $2,500 | $2,500 | Jan 4, 2024 |
| Feb 9, 2022 | 35639934Z | RESOLVE | CLASS - 1 | WORK DOESNT CONFORM TO APPROVED CONST DOCS.ATO MY INSP OF 3STYB UNDERGOING DEMO.I NOTICED SITE CONDITIONS&WORK DOESNT... | $2,500 | $2,500 | Jan 4, 2024 |
| Feb 9, 2022 | 35639936M | RESOLVE | CLASS - 1 | MECHANICAL DEMO W/O PLANS ONSITE.ATO MY INSP I OBSERVED 3STYB UNDERGOING DEMO,I NOTICED EXCAVATOR 2ONSITE BEINGUSED T... | $0 | $0 | Jan 4, 2024 |
| Jan 13, 2022 | 35589940M | RESOLVE | CLASS - 2 | PROJECT INFORMATION PANEL-FAILURE TO PROVIDE.OBSERVED AT EXP #1 CONSTRUCTION FENCE NEAR GATE CONSTRUCTION SIGNS AND I... | $625 | $625 | May 20, 2022 |
| Jan 13, 2022 | 35589939P | RESOLVE | CLASS - 2 | BC 3301.1.3 BC3307.2.2 FAILURE TO PROVIDE MANUFACTURER SPECIFICATIONS-YODOCKS.OBSERVED INADEQUATE PROTECTION OF TEMPO... | $625 | $625 | May 20, 2022 |
| Dec 9, 2021 | 35636106J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER PEDESTRIANS SW@EXP1 ALSO OBSERVED REMAINING STONES&PARAPET COPING ST... | $1,562 | $0 | Mar 4, 2022 |
| Oct 28, 2021 | 39050194X | RESOLVE | CLASS - 1 | OBSERVED APPROX. 12"X12" SIZE OF DECORATION TERRA-COTTA STONE FELL FROM 3RD FLOOR EXTERIOR FACADE ONTO PEDESTRIANS SI... | $1,250 | $0 | Jan 21, 2022 |
| Jun 3, 2020 | 39023351R | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION, (AT THE FRONT STEP EXPOSURE #1) DEFECTI... | $500 | $0 | Jul 31, 2020 |
| Oct 27, 2017 | 35280142M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35248182R ISSUED ON 09/18/17 & TO FILE A C OF C PURSUAN... | $400 | $0 | Mar 2, 2018 |
| Sep 18, 2017 | 35248182R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL.DEFECT IS:LARGE CRACKS & DETERIORATED & BULGING BRICK WORK @ VARIOUS LOCAT... | $250 | $0 | Nov 17, 2017 |
| Apr 28, 1994 | 34106309P | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BYTHE CERTIFICATE OF OCCUPANCY # 11642 FROM PRIVATE GARAGE FOR FOUR CARS & STORAGE... | $1,000 | $0 | Jan 8, 1998 |
| Apr 20, 1994 | 34106211R | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THE CERTIFICATE OF OCCUPANCY C OF O #11642 FROM PRIVATE GARAGE TO AUTO REPAIR SHOP. REMEDY: OBT... | $800 | $0 | Apr 7, 1995 |
| Jan 25, 1993 | 34084087Y | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY #11642. FROM PRIVATE GARAGE FOR (4 CARS, STORAGE O... | $875 | $0 | Apr 2, 1993 |
| Jan 25, 1993 | 34084088X | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT WORK NOTED: INTERIOR WALL PARTITION CONSTRUCTED AT CENTER OF PREMISES. REMEDY: FILE PLANS OBTAI... | $0 | $0 | Apr 2, 1993 |
| Apr 29, 1992 | 34071534Y | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT WORK NOTED INTERIOR WALL PARTITION CONSTRUCTED AND WIYH SHOWER INSTALLED LOCATED IN OFFICE AREA. | $0 | $0 | Jul 10, 1992 |
| Apr 29, 1992 | 34071533M | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY# 11642 FROM PRIVATE GARAGE FOR 4 CAR STORAGE OF BO... | $285 | $0 | Jul 16, 1992 |
| Oct 19, 1989 | 34022793H | RESOLVE | Non-Hazardous | OCCPANCY CONTRARY TO THAT ALLOWED BY THE C OF O. REMEDY: FILE FOR NEW C OF O IF FEASIBLE. | $250 | $0 | Jan 26, 1990 |
| Oct 19, 1989 | 34022794J | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. REMEDY: OBTAIN A PERMIT. | $250 | $0 | Jan 26, 1990 |
| Jul 14, 1989 | 32003035M | RESOLVE | Hazardous | IF BOILER IS NOT IN USE DISCONNECT ALL ELECTRICAL CONTROLS. GAS LINE STEAM HEADER PIPE ON TOP OF BOILER. | $0 | $0 | Nov 17, 1989 |