ECB violations
26-30 Bruckner Boulevard, Bronx • Block 02308 • Lot 0015
14 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 12, 2017 | 35261277X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT.NOTED:PART OF THE PARAPET OF 5TH FLOOR ACCESSIBLE ROOF (APPX 77 LINEAR... | $1,000 | $0 | Sep 1, 2017 |
| Jan 18, 2015 | 35117224X | ACTIVE | CLASS - 2 | OPERATION OF A PLACE OF ASSEMBLY W/O A CURRENT C OF O: 1ST FL ESTABLISHMENT CLUB MIAMI UG #6 EATING/DRINKING HAS NO P... | $800 | $0 | Apr 24, 2015 |
| Apr 9, 2003 | 34386483J | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE BLDG DEPT RECORD: LEGAL USE:1ST AND 2ND FLOORS OFFICES CELLAR STORAGE 3RD,4... | $400 | $0 | Jun 6, 2003 |
| Nov 8, 2002 | 34368478X | RESOLVE | Non-Hazardous | OCCUANCY CONTRARY TO THAT ALLOWED BY THE BUILDING DEPARTMENT RECORDS ALT# 79/1950 530/1963 FOR USE GROUP 17 ONLY LEGA... | $0 | $0 | Dec 27, 2002 |
| Jan 5, 2001 | 34270453Y | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT NOTED:HAVING INSTALLED SOUND PROOF BOARDS WITH SHEETROCK ON THE CEILING ON THE 2ND FLOOR.REMEDY... | $0 | $0 | Feb 28, 2003 |
| Sep 22, 2000 | 34253579P | RESOLVE | Non-Hazardous | PLUMBING WORK WITHOUT A PERMIT FOUND AT CEILING OF 3RD FLOOR ALL NEW DRAINAGE AND WATER PIPES FOR 4TH FLOOR BATHROOM ... | $800 | $0 | Jan 12, 2001 |
| Sep 22, 2000 | 34253580M | RESOLVE | Non-Hazardous | PLUMBING/SPRINKLER WORK WITHOUT A PERMIT FOUND AT 1ST FLOOR NEW PARTITIONS PUT UP SO SEVERAL SPRINKLER HEADS RELOCATE... | $1,000 | $0 | Jan 18, 2002 |
| Sep 14, 2000 | 34264867N | RESOLVE | Non-Hazardous | PLUMBING WORK IWTHOUT A PERMIT.ON 4FL-NEW ROUGHING FOR TOILET, LAVATORY, FLOOR DRAINS.NEW VENT AND WATER PIPES.REM:OB... | $1,000 | $0 | Aug 3, 2001 |
| Sep 14, 2000 | 34264869R | RESOLVE | Non-Hazardous | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.ROUCHING,VENT, WATER LINES FOR 4FL BATHROOM AND SINK CLOSET ARE... | $0 | $0 | Nov 24, 2000 |
| Sep 14, 2000 | 34264868P | RESOLVE | Non-Hazardous | APPROVED PLANS NOT AVAILABLE AT PREMISES AT TIME OF INSPECTION. PLUMBING.REM:PROVIDE APPROVED PLANS. | $130 | $0 | Jan 12, 2001 |
| Aug 14, 2000 | 34253365J | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT.NOTED HAVING COSNTRUCTED PARTITIONS ADJACENT TO ELEVATOR NOTE:CONSTRUCTION OUT OF METAL STUDS,S... | $250 | $0 | Oct 13, 2000 |
| Apr 21, 1999 | 38086532H | RESOLVE | Non-Hazardous | 10N11,11Q3,22I11,30I11,30O2,57Z12,57O2. -10L11 LOSE MEMORY, -22I11 HOLE CAR TOP, -30I11 HOLE PIT LEVEL | $0 | $0 | Jun 11, 1999 |
| Apr 21, 1999 | 38086531X | RESOLVE | Non-Hazardous | 11Q3,22I11,22O2,30O2,57O2. | $0 | $0 | Jun 11, 1999 |
| Jul 10, 1998 | 38077084Z | RESOLVE | Non-Hazardous | 14,M,07,35,P,17,57,0,02 14-CERTIFICATE FRAME M-MISSING 07-DOOR RE- OPEN 35-MACHINE ROOM P-NO MEANS OF ACCESS 17-VISIO... | $0 | $0 | Jan 19, 1999 |