ECB violations
284 East 163 Street, Bronx • Block 02422 • Lot 0015
16 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 21, 2023 | 39518066M | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION 6 STORIES NB I OBSERVED 1ST FL FRAMING REQUIRED STEEL BEAM W12X 22 USED W10X22 AT CL B. E-W... | $0 | $0 | Sep 1, 2023 |
| Jun 21, 2023 | 39518072Z | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION 6 STORIES NB I OBSERVED FACADE WORK WAS COMPLETED @ EXP#1 AS WELL BULKED SITE WAS ON FSWO O... | $5,000 | $5,000 | Sep 1, 2023 |
| Jun 2, 2023 | 39517350P | RESOLVE | CLASS - 2 | ACTIVE CONSTRUCTION SITE. ONGOING STUCO WORK AT EXPOSURE #1 BY 3 WORKERS, WHEN I TRIED TO GET INTO THE SITE, GATE WAS... | $1,250 | $1,250 | Aug 18, 2023 |
| Feb 13, 2023 | 39513137H | RESOLVE | CLASS - 2 | A PROPOSED 6 STORY NB ACTIVE SITE AT CONCRETE POURING FAZE ON 4 FLOOR WORKING DECK. I OBSERVED NO CONCRETE WASHOUT BO... | $2,500 | $2,500 | Sep 13, 2024 |
| Feb 13, 2023 | 39513136X | RESOLVE | CLASS - 2 | A 6 STORY NB ACTIVE SITE AT 4 FL CONCRETE POUR. I OBSERVED COLD FORM STEEL IN PLACE ON ALL FLOORS. UPON REQUEST TO CO... | $0 | $0 | Apr 21, 2023 |
| Feb 13, 2023 | 39513134M | RESOLVE | CLASS - 2 | 6 STORY NB ACTIVE SITE AT 4 FL CONCRETE POUR.OBSERVED COLD FORM STEEL IN PLACE ON CELLAR,1,2,3 FLOORS. OBSERVED MISSI... | $0 | $0 | Apr 21, 2023 |
| Feb 13, 2023 | 39513135Y | RESOLVE | CLASS - 2 | 6 STORY NB ACTIVE SITE AT 4 FL CONCRETE POUR.I OBSERVED COLD FORM STEEL IN PLACE ON CELLAR,1,2,3 FLOORS. OBSERVED MIS... | $0 | $0 | Apr 21, 2023 |
| Jan 9, 2023 | 39511395L | RESOLVE | CLASS - 1 | OBSERVED ON GOING CONSTRUCTION OPERATIONS ON JOBSITE. UPON INSPECTION OBSERVED THAT ALL FIRE EXTINGUISHERS ON JOBSITE... | $0 | $0 | Jul 13, 2023 |
| Jan 9, 2023 | 39511391Y | RESOLVE | CLASS - 1 | OBSERVED ONGOING CONSTRUCTION OPERATIONS WITH APPROX. 10 WORKERS ON JOBSITE. UPON REVIEW ON BIS AND DOB NOW, IT WAS O... | $0 | $0 | Jul 13, 2023 |
| Jan 9, 2023 | 39511392X | RESOLVE | CLASS - 1 | OBSERVED COLD FORM STEEL 1ST FLOOR EXPOSURE 1 OF JOBSITE. UPON REVIEW OF DOB APPROVED DRAWINGS OBSERVED THAT IN DETAI... | $0 | $0 | Jul 13, 2023 |
| Jan 9, 2023 | 39511393H | RESOLVE | CLASS - 1 | OBSERVED ONGOING INSTALLATION OF CMU BLOCKS AT EXPOSURE 2 2ND FLOOR OF JOBSITE. THE WORK IN PLACE IS APPROX. 5 FEET A... | $0 | $0 | Jul 13, 2023 |
| Jan 9, 2023 | 39511394J | RESOLVE | CLASS - 1 | OBSERVED ON NEWLY POURED 2ND FLOOR LARGE AMOUNTS OF CONSTRUCTION TOOLS AND MATERIALS (CEMENT MIXER, CMU BLOCKS AND FR... | $0 | $0 | Jul 13, 2023 |
| Sep 21, 2022 | 39506630X | RESOLVE | CLASS - 2 | A 4 STORY NB AT SOE PHASE ACTIVE SITE. SUPPORT OF EXCAVATION WORK AT EXP4. OBSERVED WORK CONTRARY TO PLANS PG003.02 M... | $0 | $0 | Nov 18, 2022 |
| Apr 4, 2022 | 35508253N | RESOLVE | CLASS - 1 | BC1704.1.2 SIA FAILED TO PERFORM DUTIES-SPC INSP REPORT SUBMITTED TO DEPT DATED1/6/21,SIGNED&SEALED BY RESPONDENT,CHE... | $2,500 | $2,500 | Oct 17, 2022 |
| Apr 4, 2022 | 35508251J | RESOLVE | CLASS - 1 | BC1704.1.2 SIA FAILED TO PERFORM DUTIES-SPC INSP REPORT SUBMITTED TO DEPT DATED1/19/21,SIGNED&SEALED BY RESPONDENT,CH... | $2,500 | $2,500 | Oct 17, 2022 |
| Feb 17, 2022 | 35645905K | RESOLVE | CLASS - 1 | FAILURE TO PROTECT ADJOINING STRUCTURES DURING EXCAVATION.AT TIME OF INSPECTION OF EXCAVATION PROPOSED 6 STORY NEW BU... | $5,000 | $0 | May 20, 2022 |