ECB violations
1243 Webster Avenue, Bronx • Block 02427 • Lot 0043
27 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Dec 1, 2025 | 39168790X | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS. THROUGHOUT THE BASEMENT., REPAIR A... | $2,530 | $2,530 | Dec 14, 2026 |
| Dec 1, 2025 | 39168791H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED FIRE ESCAPE DROP LADDER OBSTRUCTED WITH STAIRCASE LEA... | $2,500 | $2,500 | Nov 23, 2026 |
| Dec 1, 2025 | 39168793L | ACTIVE | CLASS - 2 | OBSERVED IN THE BASEMENT GAS VALVES BY THE GAS METERS BURIED IN THE CEILING, OPEN WASTE LINES, AND WATER LEAKING ON T... | $1,280 | $0 | May 29, 2026 |
| Feb 6, 2024 | 39105321P | RESOLVE | CLASS - 2 | OBSERVED EXCESSIVE BLACK MOLD GROWING AT CELLING IN THE BASEMENT/CELLAR LEVEL. NO MOLD REMEDIATION STARTED AT THE TIM... | $0 | $0 | Apr 19, 2024 |
| Jan 4, 2024 | 39102751L | RESOLVE | CLASS - 2 | HOLE PENETRATION FOUND EXPOSING THE CEILING/FLOOR JOIST, IN MULTIPLE LOCATIONS, CELLAR LEVEL., REPAIR AND/OR REPLACE | $655 | $0 | Mar 15, 2024 |
| Jul 28, 2022 | 39066869L | RESOLVE | CLASS - 2 | NO VENTILATION IN THE GAS METER ROOM LOCATED IN THE BASEMENT. AS PER FGC GAS METER ROOM SHALL BE PROPERLY VENTED., RE... | $0 | $0 | Sep 16, 2022 |
| Jul 28, 2022 | 39066872M | RESOLVE | CLASS - 2 | FLUE PIPE CONSTRUCTION AND METAL GAUGE NOT AS PER BOILER CODE FOR VENTING-STEAM HEADER W/O INSULATION-CORROSION AND L... | $0 | $0 | Sep 16, 2022 |
| Jul 28, 2022 | 39066870Z | RESOLVE | CLASS - 2 | OBSERVED SUMP PUMP INSTALLED IN THE BOILER ROOM, 2 INCH CAST IRON PIPING TO SANITARY LINE. NO PERMITS ON FILE AT THE ... | $0 | $0 | Sep 16, 2022 |
| May 3, 2022 | 39061475X | RESOLVE | CLASS - 2 | - AT CELLAR LEVEL,BOILER ROOM, CEILING DAMAGES, OPENING IN DEAFFERENTS LOCATION AND WALLS DAMAGES., REPAIR AND/OR REP... | $0 | $0 | Jun 17, 2022 |
| May 3, 2022 | 39061474Y | RESOLVE | CLASS - 2 | AT CELLAR EXIT DOORS DO NOT ALLOW EASY ESCAPE FROM THE BUILDING IN CASE OF EVACUATION, DOOR DO NOT CLOSE PROPERLY.ALS... | $625 | $0 | Sep 22, 2022 |
| May 3, 2022 | 39061470R | RESOLVE | CLASS - 2 | I OBSERVED IN THE BASEMENT LOCATED IN THE GAS METER ROOM ACTIVE WATER LEAK IN THE CEILING., REPAIR AND/OR REPLACE | $0 | $0 | Jun 17, 2022 |
| May 3, 2022 | 39061471Z | RESOLVE | CLASS - 2 | I OBSERVED EXCESSIVE DEBRIS/ RUBBISH IN THE BOILER ROOM LOCATED IN THE BASEMENT/CELLAR., REPAIR AND/OR REPLACE | $625 | $0 | Dec 8, 2022 |
| May 3, 2022 | 39061469J | RESOLVE | CLASS - 2 | I OBSERVED EXCESSIVE COMBUSTIBLE STORAGE IN THE GAS METER ROOM THAT IS LOCATED IN THE BASEMENT/CELLAR., REPAIR AND/OR... | $500 | $0 | Dec 12, 2022 |
| Jan 14, 2020 | 37017405J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39002207J ISSUED ON 4/17/19 AND TO FIL... | $1,280 | $0 | Sep 18, 2020 |
| Oct 10, 2019 | 35442330Z | RESOLVE | CLASS - 1 | FAILURE TO INSTALL GROUNDING ELECTRODE CONDUCTOR IN ACCORDANCE WITH SECTION.I OBSERVED IN THE BASEMENT AREA THE IMPRO... | $1,200 | $0 | Nov 29, 2019 |
| Apr 17, 2019 | 39002207J | RESOLVE | CLASS - 2 | HOLES IN BOILER ROOM WALL-NO BLOW-OFF DRAIN ON SAFETY VALVE-WATER LEVEL GLASS DIRTY-DEBRIS IN BOILER ROOM; CORRECT AL... | $625 | $0 | Jun 7, 2019 |
| Aug 22, 2018 | 35347161L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: AT CELLAR LEVEL THERE A... | $6,250 | $0 | Oct 19, 2018 |
| Jul 10, 2018 | 35341894L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER:NO FIRE STOPPING PERBC 712.3;27-345.NOTED:@CELLAR LEVEL,THERE ARE H... | $0 | $0 | Aug 31, 2018 |
| May 14, 2018 | 35331805L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3;27-345. AT CELLAR LEVEL OPEN PARTS O... | $2,530 | $0 | Jun 29, 2018 |
| May 14, 2018 | 35331828Y | RESOLVE | CLASS - 2 | EC-110.2(A)DEFECTIVE WIRING IN USE.OBSERVED IN BASEMENT.EXPOSE WIRING SERVICE ENTRANCE CONDUCTORS BURRIED IN CONCRETE... | $400 | $0 | Jun 29, 2018 |
| Jan 9, 2018 | 35394368K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35347161L ISSUED ON 08/22/18 AND TO FI... | $830 | $0 | Mar 29, 2019 |
| May 30, 2017 | 35267492X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS,EXIT DISCHARGES,& PUBLIC CORRIDORS PER BC 1... | $250 | $0 | Nov 3, 2017 |
| May 30, 2017 | 35267825P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.OBSERVED ON 5/30/17 AT ABOVE ADDRESS IN BSMT 1 INCH SPRINKLER MAIN ... | $250 | $0 | Nov 3, 2017 |
| May 30, 2017 | 35267491Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMLIANT MANNER. NO FIRE STOPPING PERBC712.3;27-345. NOTED: AT TIME OF INSPECTION,OB... | $0 | $0 | Jul 21, 2017 |
| May 30, 2017 | 35267685M | RESOLVE | CLASS - 2 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIALS,APPARATUS,DEVICES,APPLIANCE OR WIRING IN USE. OBSERVED EX... | $400 | $0 | Nov 3, 2017 |
| May 30, 2017 | 35267399L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.ON 5/30/17,OBSERVED AT ABOVE ADDRESS PIPE APPEARS TO HAVE A LEAK TH... | $250 | $0 | Nov 3, 2017 |
| May 30, 2017 | 35267684K | RESOLVE | CLASS - 2 | ELECTRICAL WORK W/O A PERMIT. OBSERVED THROUGHOUT BLDG HALLS NEW LIGHTS W/EMERGENCY BACK UP. RECEPTACLE OUTLET IN BAS... | $200 | $0 | Nov 3, 2017 |