ECB violations
1021-1029 Findlay Avenue, Bronx • Block 02433 • Lot 0036
11 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 20, 2021 | 35632804Z | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE&MAINTAIN GUARDRAIL SYSTEM AS PER CODE ATOI ON ACTIVE 7STYNB CONST NOTICE ON ROOF&7FL@EXP3&4 THAT G... | $2,500 | $0 | Dec 14, 2022 |
| Oct 20, 2021 | 35632809H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN SAFETY ONSITE-UNCAPPED REBARS ATOI ON ACTIVE 7STYNB CONST SITE,NOTICE IN STAIRCASE ONSITE REBAR T... | $5,000 | $0 | Dec 14, 2022 |
| Oct 20, 2021 | 35632806M | RESOLVE | CLASS - 1 | BC3308.6 FAILURE TO PROVIDE&MAINTAIN HORIZ SAFETY NETTING AS PER CODE ATOI ON ACTIVE 7STYNB CONST SITE.NOTICE UPPERMO... | $2,500 | $0 | Jan 21, 2022 |
| Oct 20, 2021 | 35632807Y | RESOLVE | CLASS - 1 | BC3301.6 FAILURE TO HAVE DESIGN DRAWINGS FOR TEMP CONST ONSITE ATOI ONACTIVE 7STYNB CONST SITE,NOTICE MATERIAL PLATFO... | $625 | $0 | Jan 21, 2022 |
| Oct 20, 2021 | 35632808X | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF MATERIALS@EDGE.ATOI ON ACTIVE 7STYNB CONST SITE NOTICE MATERIALS STORED@LEADING EDGE@EXP4 ROOF&ON T... | $2,500 | $0 | Jan 21, 2022 |
| Oct 20, 2021 | 35632810P | RESOLVE | CLASS - 2 | SUPER-NO CORRECTION OF UNSAFE CONDITIONS.ATOI ON ACTIVE 7STYNB CONST SITE,NOTICE CONDITIONS ONSITE HAZARDOUS CONDITIO... | $2,500 | $0 | Dec 14, 2022 |
| Oct 20, 2021 | 35632803R | RESOLVE | CLASS - 1 | BC3309.10 FAILURE TO PROVIDE&MAINTAIN ROOF PROTECTION AS PER CODE ATOION ACTIVE 7STYNB CONST SITE NOTICE THAT CONTRAC... | $2,500 | $0 | Jan 21, 2022 |
| Oct 20, 2021 | 35632805K | RESOLVE | CLASS - 1 | WORK CONTRARY TO SSP ATOI ON ACTIVE 7STYNB CONST SITE NOTICE CONDITIONS ON SITE THAT FAILED TO CONFORM TO SSP&WAS ALS... | $625 | $0 | Jan 21, 2022 |
| Oct 4, 2021 | 35505654K | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.NOTE AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE ... | $0 | $0 | Dec 17, 2021 |
| Oct 4, 2021 | 35505653Z | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.NOTE:AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE ... | $625 | $0 | Dec 17, 2021 |
| Aug 6, 2021 | 39045594Z | RESOLVE | CLASS - 2 | ALL INSTALLED FOUNDATION WALLS ON EXPOSURES 1, 2, 3 AND 4 WITH 1" (R-5) OUTBOARD CONTINUOUS INSULATION CONTRARY TO 2"... | $620 | $0 | Oct 1, 2021 |