| Oct 26, 2016 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE AND CERAMIC FLOOR TIL... | — | Nov 3, 2016 |
| Oct 26, 2016 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5A, ... | 5A | Nov 30, 2016 |
| Oct 26, 2016 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). THAT IS DEFECTIVE IN THE ENTIRE APARTMENT... | 5A | Nov 30, 2016 |
| Oct 26, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE KI... | 5A | Nov 30, 2016 |
| Oct 26, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT... | 5A | Nov 30, 2016 |
| Oct 26, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LO... | 5A | Nov 30, 2016 |
| Sep 12, 2016 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL IN THE BATHROO... | 2A | Dec 16, 2016 |
| Sep 12, 2016 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SAGGING WOOD UNDERLAYMENT AT THE FLO... | 2A | Dec 16, 2016 |
| Sep 12, 2016 | B | VIOLATION CLOSED | SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING AND WEST ... | 2A | Oct 17, 2016 |
| Sep 12, 2016 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM... | 2A | Oct 17, 2016 |
| Sep 12, 2016 | B | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT THE EAST WALL IN THE BATHR... | 2A | Oct 17, 2016 |
| Sep 12, 2016 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC LIGHT FIXTURE AT THE CEILING IN THE 5th ROOM FROM... | 2A | Dec 16, 2016 |
| Sep 12, 2016 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 4th ROOM... | 2A | Oct 17, 2016 |
| Sep 9, 2016 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BASIN IN THE KITCHEN LOCATED AT APT 4B, 4th STORY, 1s... | 4B | Oct 14, 2016 |
| Sep 9, 2016 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 4B | Oct 7, 2016 |
| Sep 9, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE 1st ROOM FROM EAST L... | 4B | Oct 14, 2016 |
| Sep 9, 2016 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE ON NORTH RISER IN THE 6th ROOM FROM EAST LOCATED AT ... | 4B | Dec 13, 2016 |
| Sep 9, 2016 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING I... | 4B | Sep 17, 2016 |
| Sep 7, 2016 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS ... | — | Oct 12, 2016 |
| Jun 6, 2016 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB. IN THE BATHROOM LOCATED AT APT 4A, 4th... | 4A | Jul 11, 2016 |
| Jun 1, 2016 | B | VIOLATION CLOSED | SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITI... | — | Jul 6, 2016 |
| Jun 1, 2016 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT WALLS AT 1ST ST... | — | Jul 6, 2016 |
| Jun 1, 2016 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WALLS AT 1ST STY LOBBY | — | Sep 4, 2016 |
| Jun 1, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT 1ST STY LOBBY | — | Jul 6, 2016 |
| Jun 1, 2016 | A | VIOLATION CLOSED | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE PUBLIC HALLS AND STAIRS | — | Sep 4, 2016 |
| Mar 4, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CAULKING AT WASH BASIN IN THE BATHROOM LOCATED AT APT 5B,... | 5B | Apr 8, 2016 |
| Mar 4, 2016 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 5B | Apr 8, 2016 |
| Mar 4, 2016 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY,... | 5B | Apr 8, 2016 |
| Mar 4, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTERBALANCE AT LOWER WINDOW SASH IN THE 1st ROOM FROM E... | 5B | Apr 8, 2016 |
| Mar 4, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMAL FINISH ON BATHTUB I... | 5B | Apr 8, 2016 |
| Mar 4, 2016 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS ... | 5B | Apr 8, 2016 |
| Mar 4, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILE AT SOUTH WALL IN T... | 5B | Apr 8, 2016 |
| Mar 4, 2016 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS ... | 5B | Apr 8, 2016 |
| Mar 4, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTERBALANCE AT LOWER WINDOW SASH IN THE 5th ROOM FROM E... | 5B | Apr 8, 2016 |
| Mar 4, 2016 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN DRAIN PIPE ON WASH BASIN IN THE BATHROOM L... | 5B | Apr 8, 2016 |
| Oct 26, 2015 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR UNKEYED CEILING IN ... | — | Nov 3, 2015 |
| — | I | VIOLATION DISMISSED | SECTION 27-2091(C) ADM CODE THE PROPERTY HAS BEEN ISSUED AN ORDER TO IDENTIFY AND ADDRESS UNDERLYING CONDITIONS AND V... | — | — |
| Oct 19, 2015 | A | VIOLATION DISMISSED | SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME... | — | Jan 22, 2016 |
| Oct 13, 2015 | B | VIOLATION DISMISSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT SOUTH WALL IN THE 4t... | 5B | Nov 17, 2015 |
| Oct 13, 2015 | B | VIOLATION DISMISSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... WALLS IN THE BATHROOM L... | 5B | Nov 17, 2015 |
| Oct 13, 2015 | A | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE CABINET IN THE KITCHEN LOCATED AT APT 5B, 5th S... | 5B | Jan 16, 2016 |
| Oct 13, 2015 | B | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND W... | 5B | Nov 17, 2015 |
| Oct 13, 2015 | B | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL ... | 5B | Nov 17, 2015 |
| Oct 13, 2015 | A | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN TH... | 5B | Jan 16, 2016 |
| Oct 13, 2015 | B | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT... | 5B | Nov 17, 2015 |
| Sep 10, 2015 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE 1st ENTIRE APARTMENT FROM EAST LOCATED A... | 4A | Oct 15, 2015 |
| Sep 10, 2015 | B | VIOLATION CLOSED | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK AT ROOM DOOR LEADING TO FIRE ESCAPE IN ... | 4A | Oct 15, 2015 |
| Sep 10, 2015 | B | VIOLATION CLOSED | SECTION 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE 2... | 4A | Oct 15, 2015 |
| Sep 10, 2015 | B | VIOLATION DISMISSED | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE 1st BATHROOM FROM EAST LOCATED A... | 4A | Oct 15, 2015 |
| Sep 10, 2015 | B | VIOLATION DISMISSED | SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st FO... | 4A | Oct 15, 2015 |