Skip to content

ECB violations

1136 Grant Avenue, Bronx • Block 02449 • Lot 0013

15 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Apr 13, 2021 39039662K RESOLVE CLASS - 2 MASONRY CHIMNEY FLUE MISSING CLEAN OUT AT BASE AS PER FGC 501.15.3, SYSTEM PIPING SHALL BE INSULATED AS PER MC 1204, ... $3,125 $0 Jul 30, 2021
Apr 6, 2016 35159691K RESOLVE CLASS - 2 FAILURE TO PROPERLY BOND ELECTRICAL SYSTEMS. BSMT SERVICE SWITCH:NEUTRAL BAR IS NOT BONDED TO ENCLOSURE. REMEDY: PROV... $7,500 $0 Jun 3, 2016
Apr 6, 2016 35159690Z RESOLVE CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. ONJANUARY 4,2016 AN ELECTRICAL VIOLATION WAS ISSU... $6,000 $0 Jun 3, 2016
Jan 14, 2016 35142373Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER:FAILURE TO MAINTAIN EQUIPT-BOILER.OBSERVED ON JAN 14 2016-BIS RECOR... $500 $0 Jul 12, 2016
Jan 14, 2016 35142370Z RESOLVE CLASS - 1 WORK NO PERMIT-OBSERVED ON JAN 14 2016 @BST BOILER ROOM OUTSIDE GAS METER LOCN-INSTALLED NEW GAS PIPING TO BOILERS & ... $0 $0 Jul 12, 2016
Jan 14, 2016 35114371M RESOLVE CLASS - 1 FILE A CERTIFICATE FORM APPLICATION ETC CONTAINING A MATERIAL FALSE STATEMENTS UNDER JOB APPL#220459395 ISSUED 7-21-1... $4,800 $0 Jul 12, 2016
Jan 14, 2016 35114372Y RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: EXCESSIVE DEBRIS AT EXP#2 & 3. DEFECTIVE FIRE ESCAPE LADDER T... $1,000 $0 Jul 12, 2016
Jan 14, 2016 35114373X RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. USE OF PROHIBITED DOOR &/OR HANDWARE PER BC 1008.1.8 & 27-371(J). ... $500 $0 Jul 12, 2016
Jan 14, 2016 35142371K RESOLVE CLASS - 1 GAS BEING SUPPLIED TO BLDG W/OUT INSP & CERT BY DOB OBSERVED ON JAN 142016 @2:30 PM IN BST & OUTSIDE GAS UNITS ON & I... $1,000 $0 Jul 12, 2016
Jan 14, 2016 35142372M RESOLVE CLASS - 2 FAILURE TO BLDG IN CODE COMPLIANT MANNER-FAILURE TO COMPLY W/LAW OF DRAINAGE SYSTEM PER PC 702.1 & 27-911 OBSERVED ON... $500 $0 Jul 12, 2016
Jan 4, 2016 35158735Z RESOLVE CLASS - 2 UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE DEFECTIVE O... $800 $0 Jul 8, 2016
Jan 4, 2016 35158732N RESOLVE CLASS - 2 ELECTRICAL WORK W/OUT PERMIT OBSERVED @2:30PM NEW BRANCH CIRCUIT WIRING INSTALLED FOR OUTLETS,SWITCHED,FIXTURES IN AP... $0 $0 Jul 12, 2016
Jan 4, 2016 35158733P RESOLVE CLASS - 1 FAILURE TO GROUND ELECTRICAL SYSTEM NO SERVICE GROUND CONDUCTOR PROVIDED TO 100 AMP SERVICE SWITCH INSTALLED IN BSMT.... $4,800 $0 Jul 12, 2016
Jan 4, 2016 35158734R RESOLVE CLASS - 1 UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE SERVICE ENT... $1,000 $0 Jul 8, 2016
Jan 4, 2016 35158736K RESOLVE CLASS - 2 FAIL TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS ENCLOSURES CABLE/(ARMOR) SERVICE RACEWAY ON SIDE O... $1,200 $0 Jul 8, 2016