Sep 11, 2024 35686309P RESOLVE CLASS - 1 28-323.8 AND RCNY 103-13(5). FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES C... $2,500 $2,500 Jun 27, 2025
Aug 20, 2024 35683715R RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AT TIME OF INSPECTIONIT WAS OBSERVED AT EXPOSURE 1(WEST ELEVATION) A... $1,280 $0 Sep 30, 2025
Aug 8, 2024 35681774H RESOLVE CLASS - 1 FAILURE TO PROVIDE OBSTRUCTED EXIT PASSAGEWAY. AT THE TIME OF INSPECTION, I OBSERVED FLOWER POTS AND OTHER OBJECTS ON... $1,250 $0 Nov 3, 2025
Feb 15, 2022 39056615M RESOLVE CLASS - 1 CLASS 1 VIOLATION ISSUED DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER. INSTALL F... $3,125 $0 Jun 3, 2022
Nov 1, 2021 39050358N RESOLVE CLASS - 1 CLASS 1 VIOLATION ISSUED, DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER, INSTALL,... $6,250 $0 Feb 4, 2022
Aug 28, 2021 39046704P RESOLVE CLASS - 1 CEASE USE ITEMS,/ CAR DOOR RESTRICTOR ALTERED AND NOT WORKING,/ DLM NOT WORKING,PERFORM ALL REPAIRS THEN CONTACT NYCD... $1,250 $0 Dec 3, 2021
Oct 15, 2018 37013253L RESOLVE CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURT... $0 $0 Mar 15, 2019
Mar 4, 2013 38226087K RESOLVE CLASS - 2 12Q03,39X10,61T07,68M07,70O02,77Q03,99U15. 39X10-REPAIR LIGHT TOP OF CAR; 61T07-PROVIDE COMPANY STICKER FOR MAIN LINE... $0 $0 Apr 19, 2013
Mar 18, 2010 34839413N ACTIVE CLASS - 2 SEC 27-357(D) BC 1105.1 MISC VIOL: PEOPLE WITH PHYSICAL DISABILITIES PRIMARY ENTRANCE INACCESSIBLE, NOTED: EXTERIOR E... $4,000 $0 Jul 16, 2010
Nov 30, 2009 34823880X RESOLVE CLASS - 2 FAILURE TO FILE CERTIFICATE OF CORRECTION FOR VIO#34786863Y - FILE CERT OF CORR. $4,000 $0 Mar 5, 2010
Jul 9, 2009 34786863Y RESOLVE CLASS - 1 FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. DEFECT NOTED: AT FRONTMAIN ENTRANCE TO BLDG COURT, CONCRETE SLAB WALK... $5,000 $0 Sep 4, 2009
Jun 7, 2009 34755397Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN: AT FRONT OF PREMISES CONCRETE WALKING & SUPPORTS IN STATE OF DISREPAIR & COLLAPSING. REM: MAKE S... $2,500 $0 Aug 7, 2009
Jun 5, 2009 34786674P RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: DEFECT NOTED: AT FRONT ENTRY STOOP OF BLDG ENTRY, SECTION OF PAVEM... $5,000 $0 Aug 7, 2009
Jan 14, 2009 38200123N RESOLVE CLASS - 2 40P16, 08V01, 07L10, 10H11, 17M07, 32H10, 70O02. 40P16- PROVIDE ACCESSTO MACHINE ROOM. 08V01- ADJUST FLOOR STOPS 1 TO... $2,500 $0 Mar 6, 2009
Sep 22, 2003 34412012J RESOLVE Hazardous WORK W/O A PERMIT.WORK NOTED:HAVING INSTALLED A GAS STOVE AND 3 PIECE BATHROOM WITH PARTIONS AT A LEVEL FLR AT GAS ME... $2,500 $0 Nov 7, 2003
Sep 22, 2003 34412011H ACTIVE Non-Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY THE BLDG,DEPARTMENT AND RECORDS.FROM LEGAL USE:GAS METER ROOM AT(A) LEVEL FL TO... $2,500 $0 Nov 7, 2003
Apr 17, 2002 38122705M RESOLVE Non-Hazardous 14M07-22D06-09B07-57O02-18Q07-16H07-74Q07-74M07-03Q02-03O02-30O02-28H11-53M07. 14-AS PER RULE 27-1004A 27-1004B, 09-P... $2,500 $0 Jun 7, 2002
Oct 26, 2001 34305943Y ACTIVE Hazardous RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED NUMBER OF FAMILIES. C OF O #1130. FR... $800 $0 Nov 1, 2002
Jul 31, 1999 38089403P RESOLVE Non-Hazardous 57O 08V 50Y $180 $0 Jan 28, 2000
Mar 22, 1999 34177036R RESOLVE Non-Hazardous FAILURE TO FILE A REPORT OF COMPLIANCE W/ LL 16/84 CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTION SYSTEMS... $400 $0 May 14, 1999
Jan 21, 1998 38069295Z RESOLVE Non-Hazardous 03I,14L,51Y,53M,57O,75U,-03 CAR FAN MISSING REPLACE 51 WORM GEAR OIL LOW $2,500 $0 Jul 10, 1998
Apr 28, 1997 34145657N RESOLVE Hazardous FAILURE TO MAINTIAN DEFECT IS: TILE REMOVED FROM WALLS AND PLASTER REMOVED FROM CEILING IN BATHROOM OF APARTMENT 3B. ... $1,000 $0 Nov 28, 1997
Aug 17, 1995 34119134P RESOLVE Hazardous USE OF RIGGING EQUIPMENT WITHOUT A SPECIAL RIGGISH LICENSE.FAILUE TO USE(SAFETY BELTS)WHILE WORKING ON A SWINGING SCA... $2,500 $0 Mar 22, 1996
Mar 30, 1995 34093320X RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR OF BLDG:ON THE SOUTH WEST CORNER 5+6FLS THE BRICK SECTION HAS MOVED FOWARD APP 2TO3 INCH... $1,000 $0 May 26, 1995
Mar 6, 1995 34121107M RESOLVE Non-Hazardous FAILURE TO MAINTAIN:EXTERIOR BLDG WALL IS DEFECTIVE, BRICKWORK PULLINGAWAY FROM BLDG LOCATED SOUTHWEST CORNER AT PARA... $350 $0 Jul 28, 1995
Feb 27, 1995 38046941M RESOLVE Non-Hazardous 18R,37R,15L.37-REMOVE WIRE JUMPERS 35-44 ON LOCK CIRCUIT CEASE USE UNTIL THIS ITEM IS CORRECTED BEFORE RETURNING TO S... $1,000 $0 May 26, 1995
Jun 8, 1994 34111162X RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL DEFECT NOTED: SOUTHWEST CORNER OF PARAPET WALL IS PULLING AWAY FROM BUILDI... $350 $0 Apr 6, 1995
Jul 7, 1993 38034893Z RESOLVE Non-Hazardous 73X. 73. RESTORE ELEVATOR SERVICE SO PROPER INSPECTION CAN BE MADE BY THIS DEPT. $1,000 $0 Sep 10, 1993
Feb 3, 1993 34084180Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL DEFECT IS SOUTHWEST CORNER OF PARAPET WALL AT FRONT OF BUILDING AT FRONT O... $5,000 $0 Jul 29, 1993
Oct 29, 1991 38019122P RESOLVE Non-Hazardous 10L,15M,37R,35O,57O,(10)MAKE ELEV GO TO BASEMENT (15)REPLACE MATCH DOOR GLASS WHERE NEC. (37)FILE BN FOR NEW CONTROLL... $1,000 $0 Jan 3, 1992
Oct 28, 1991 38016614H RESOLVE Non-Hazardous 57O,35O,15#,37R,74#,35-REMOVE OLD CONTROLLER FROM MOTOR ROOM. 15-REPAIR VISION GLASS WERE NEEDED. 37-FILE BUILDING NO... $1,000 $0 Jan 3, 1992
May 22, 1991 34051367H RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS: SOUTHEAST CORNER OF PARAPET WALL AT FRONT OF BUILDING IS PULLI... $1,000 $0 Sep 27, 1991
Mar 6, 1991 38007848X RESOLVE Non-Hazardous 14M;11B;17M;15F;35O;37#; 37.FILE BUILDING NOTICE FOR NEW CONTROLLER AND SELECTOR WITH THIS DEPARTMENT. $2,000 $0 Aug 9, 1991
Mar 12, 1990 34036812L RESOLVE Hazardous FAILURE TO MAINTAIN: BRICKWORK AT ALL CORNERS OF ENTRANCE COURTS AND ENDS OF BLDG WITH A BUTTING CORNER WINDOW WITH 4... $0 $0 Jun 28, 1990
Mar 7, 1990 34036803J RESOLVE Hazardous FAILURE TO MAINTIAN: REAR ELEVATED BRIDGE OR WALKWAY BROKEN & DEFEC- TIVE COLLAPSED SLAB REPLACE BY TEMPO WOOD PLANKI... $0 $0 Jun 28, 1990
Sep 18, 1989 34022784X RESOLVE Unknown FAILURE TO MAINTAIN. CONCRETE AND CORRODED STEEL AT REAR ABOVE YARD THE BRIDE IS ENTIRELY CORRODED. REMEDY: OBTAI APP... $500 $0 Jan 5, 1990
Sep 18, 1989 34022785H RESOLVE Unknown FAILURE TO MAINTAIN. BRICKWORK AT ALL CORNERS OF ENTRANCE COURT AND OUTSIDE COURTS AND ENDS OF BUILDING WITH A BUTTIN... $500 $0 Jan 5, 1990
Sep 18, 1989 34022783Y RESOLVE Hazardous FAILURE TO MAINTAIN. CONCRETE CORRODED STEEL AT REAR ABOVE YARD THE BRIDGE IS ENTIRELY CORRODED. $0 $0 Dec 8, 1989
Nov 10, 1988 34007116P RESOLVE Non-Hazardous FAILING TO MAINTAIN BRICKWORK ALL CORNERS AT ENTRANCE COURT OUTSIDE COURTS AND ENDS OF BLDG. REMEDY: REMOVE ALL LOOSE... $0 $0 Mar 1, 1990
Nov 10, 1988 34007118Z RESOLVE Non-Hazardous FAILING TO MAINTAIN: LARGE SECTION OF REINFORCED CONCRETE SLAB COLLAPSED AND LARGE PORTION OF SAME PLAB IS HANGING PR... $0 $0 Mar 1, 1990
Nov 10, 1988 34007115N RESOLVE Non-Hazardous FAILING TO MAINTAIN DEFECTIVE SPALLING CONCRETE AND CORRODED ETED AT REAR. REMEDY: SUBMIT A REPORT AS TO THE STRUCTUR... $0 $0 Mar 1, 1990
Nov 10, 1988 34007114L RESOLVE Non-Hazardous FAILING TO MAINTAIN: LARGE SECTION OF REINFORCED CONCRETE HAS COLLAPSED AND A PARTION OF SAME PLAB. REMEDY: MAKE SAFE... $0 $0 Mar 1, 1990
Aug 22, 1988 34006808L RESOLVE Non-Hazardous FAILING TO MAINTAIN LARGE SECTION OF REINFORCED CONCRETE LAB HAS COLLAPSED AND A PORTION OF SAME SLAB IS HANGING PREC... $1,000 $0 Oct 14, 1988
Aug 22, 1988 34006812Y RESOLVE Non-Hazardous FAILING TO MAINTAIN LARGE SECTION OF REINFORCED CONCRETE SLAB HAS COLLAPSED AND A LARGE PORTION OF SAME SLAB IS HANGI... $0 $0 Jun 14, 1990
Aug 22, 1988 34006810K RESOLVE Non-Hazardous FAILING TO MAINTAIN BERICKWORK ALL CORNERS AT ENTRANCE COURT OUTSIDE COURTS AND ENDS OF BUILDING WITH ABUTING CORNER ... $1,000 $0 Oct 14, 1988
Aug 22, 1988 34006809N RESOLVE Non-Hazardous FAILING TO MAINTAIN DEFECTIVE APOLLING CONCRETE AND CORRODED STEEL AT REAR ABOVE YARD ENTIRE WALKWYAY ENCASED STEEL R... $1,000 $0 Oct 14, 1988