ECB violations
790 Grand Concourse, Bronx • Block 02458 • Lot 0085
30 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 21, 2024 | 39122641Z | RESOLVE | CLASS - 1 | CEASE USE ITEM: MISSING TAPE SELECTOR SWITCH AS NOW REQUIRED BY K3. CLASS 2 ITEMS: ADJUST SADDLE TO SILL CLEARANCE AT... | $1,250 | $0 | Nov 3, 2025 |
| Jul 10, 2024 | 39118856Y | ACTIVE | CLASS - 1 | CLASS 1 CEASE USE ITEM: 10AMP CONTROLLER LINE FUSE IS BYPASSED. CLASS 2 ITEMS: HOIST ROPES SHOW SIGNS OF ROUGE. PROVI... | $1,250 | $0 | Aug 5, 2025 |
| Jun 25, 2024 | 39117689L | RESOLVE | CLASS - 1 | ELEVATOR CURRENTLY STUCK BETWEEN BASEMENT AND LOBBY FLOOR, OUT OF SERVICE, RESTORE TO SERVICE | $1,250 | $0 | Aug 5, 2025 |
| Mar 2, 2023 | 39080673K | RESOLVE | CLASS - 1 | DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED(CU). BRAKE MAINTENANCE TAG MUST HAVE THE MONTH DAY AND YEAR. | $1,250 | $0 | May 19, 2023 |
| Sep 9, 2022 | 39069738P | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED RECURRING, DLM IMPROPERLY INSTALLED ON THIS DEVICE, NO FIREMAN SERVICE PRESENTED IN CONTROLL... | $3,125 | $0 | Nov 4, 2022 |
| Dec 1, 2021 | 39052158H | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED DLM IMPROPER INSTALLED ON THIS DEVICE . NO FIREMAN SERVICE PRESENT IN CONTROLLER. INSTALL FI... | $1,250 | $0 | Jul 15, 2022 |
| Aug 19, 2021 | 39046342R | RESOLVE | CLASS - 1 | CLASS 1 ITEM, NO FIRE SERVICE IN CONTROLLER REMEDY; AS PER CODE PROVIDE AND INSTALL FIRE SERVICE IN CONTROLLER AND TO... | $1,250 | $0 | Apr 29, 2022 |
| Mar 22, 2021 | 39038057H | RESOLVE | CLASS - 1 | DOOR RESTRICTOR ALTERED/INOPERATIVE. CONTACT NYCDOB FOR RE-INSPECTION. PROVIDE FIRE SERVICE AS PER 2.27.3.3.6 OF APPE... | $1,250 | $0 | May 7, 2021 |
| Mar 25, 2019 | 38268870H | RESOLVE | CLASS - 1 | C/U 5A10,20I11,67X10; (5.A.10)DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLE.THIS IS A SAFETY DEVICE TO ENSUR... | $1,250 | $0 | May 31, 2019 |
| Oct 15, 2018 | 37013750M | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $1,250 | $0 | May 17, 2019 |
| Sep 28, 2018 | 35352001Z | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS AS PER 3307.6.4.4.NOTE:AT TIME OF INSPECTION I OBSERVED SIDEW... | $2,400 | $0 | Dec 14, 2018 |
| Oct 17, 2013 | 38228632X | RESOLVE | CLASS - 2 | 3X10, 40P16. 3-PHONE; 40-PROVIDE ACCESS | $0 | $0 | Dec 6, 2013 |
| Jan 31, 2013 | 38225223L | RESOLVE | CLASS - 2 | 100I10,59H11,68U7,98BB5,99BB5,38O2,77K11,3K11. 100-PHONE NOT WORKING; 3-STRIKE POST RUSTED. | $250 | $0 | Mar 29, 2013 |
| Jul 8, 2010 | 34862013J | RESOLVE | CLASS - 2 | FAIL TO MAINTAIN BLDG WALLS & APPURTENANCES. A/C SUPPORTS 1ST FL SOUTH CHAIR PLUS WOOD FIRE ESCAPE ANCHORS-EAST (REAR... | $500 | $0 | Apr 29, 2011 |
| Jul 8, 2010 | 36013992Z | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6 ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS.PERIODIC INSPECTION OF EXTERI... | $8,000 | $0 | Oct 15, 2010 |
| Jul 8, 2010 | 36013604H | RESOLVE | CLASS - 2 | FAIL TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR... | $800 | -$800 | Apr 29, 2011 |
| Oct 23, 2009 | 36009967P | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/CODE PROVISIONS: PERIODIC INSP OF EXTERIOR WA... | $4,000 | $0 | Jan 22, 2010 |
| Jan 23, 2009 | 36007949M | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... | $4,000 | $0 | Sep 18, 2009 |
| Dec 19, 2007 | 34418637R | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG. WEST ELEVATION SHOWS BLOCKS OF WOODUNDER A/C UNITS & BLOCKS OF WOOD OF FACADE SILL... | $2,500 | $0 | Feb 15, 2008 |
| Sep 11, 2003 | 38141792N | RESOLVE | Hazardous | 52,L,11 70,L,11 54,L,10 85,U,5 25,#,7 41,H,11 44,H,# CEASE USE UNTIL GOVERNOR ROPE TAIL ROPE AND SELECTION ROPE IS RE... | $500 | $0 | Aug 20, 2004 |
| Sep 9, 2003 | 38141226Z | RESOLVE | Non-Hazardous | 15,M,07 03,K,10 12,Q,03 31,H,10 21,Q,03 66,0,02 84,I,10 39,W,06 44,BB,05 84,R,09 84,M,07 55,Y,10 35,Q,03 41,Q,06 59X,... | $350 | $0 | Aug 20, 2004 |
| Jul 15, 2003 | 34380272M | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ELEVATOR LANDING SIGN THAT SHALL READ " IN CASE OF FIRE USE STAIR UNLESS OTHERWISE INSTRUCTED" ON ... | $600 | $0 | May 28, 2004 |
| Dec 30, 1999 | 38091847Z | RESOLVE | Non-Hazardous | 14M,8V,8O,35P,57O,11Q,75B,18M,74M,5B. INTERLOCK COVER MISSING ON BASEMENT FLOOR. PROVIDE PLATE IN CAB. ADJUST CAR DOO... | $0 | $0 | Feb 25, 2000 |
| Apr 11, 1997 | 38059166N | RESOLVE | Hazardous | 18M,38R,03I,36W,57O,50Y,73O,35O,53L,03U,. 18- REPLACE COVER ON INTERLOCK BASEMENT LANDING 38- REMOVE JUMPER FROM REVE... | $1,000 | $0 | Jul 25, 1997 |
| Jan 26, 1996 | 38052564R | RESOLVE | Non-Hazardous | 73X RESTORE ELEV TO SERVICE SO, A PROPER INSPECTION CAN BE MADE BY THE DEPT. 74O CLEAN TOP OF CAR 35P ACCESS TO M/R | $0 | $0 | Apr 26, 1996 |
| Jun 15, 1995 | 38049130M | RESOLVE | Non-Hazardous | 02L,03B,08V,14M,35M,56H. 03 CAB PANEL REMOVE GAP. 08-FLOOR STOPS. 35 -PROVIDE LADDER OR STEPS TO MOTOROOM. | $1,000 | $0 | Aug 25, 1995 |
| Nov 9, 1994 | 38045454K | RESOLVE | Non-Hazardous | 14M, 35P, 57O. | $1,000 | $0 | Jan 13, 1995 |
| Oct 28, 1992 | 38028668L | RESOLVE | Non-Hazardous | 73#,46H,35L,(73)PERFORM 5YR TEST PROPERLY TAG DEVICE & FILE ELV3 FORM(35)REPAIR LADDER TO MOTOR ROOM. | $5,000 | $0 | Jan 15, 1993 |
| Feb 5, 1992 | 38016621X | RESOLVE | Non-Hazardous | 57O,35O,08V,73#,74O,46H, (73) PERFORM 5 YEAR TEST, PROPERLY TAG DEVICEAND FILE ELV-3 FORM. (74) CLEAN CAR TOP. | $150 | $0 | Sep 25, 1992 |
| Oct 28, 1991 | 38016612Y | RESOLVE | Non-Hazardous | 35P,57O,08V,74#,14M,74O,35-PROVIDE ACCESS TO MOTOR ROOM 74-REPAIR LIGHT IN ELEV CAB 74-CLEAN TOP OF CAR | $1,000 | $0 | May 7, 1992 |