Skip to content

ECB violations

955-967 Sheridan Avenue, Bronx • Block 02461 • Lot 0074

29 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 12, 2026 39557870P ACTIVE CLASS - 2 AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED AT EXPOSURES 1 IN PLACE AT OCCUPIED 7-STORY MIXED-USE BUILDING. SIDEWAL... $1,250 $1,250 Oct 16, 2026
Jun 22, 2026 39193254R ACTIVE CLASS - 2 FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS 39135626N, FILE A CERTIFICATE OF CORRECTION $1,250 $1,250 Sep 4, 2026
Jun 22, 2026 39193255Z ACTIVE CLASS - 2 FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS 39135625L, FILE A CERTIFICATE OF CORRECTION $1,250 $1,250 Sep 4, 2026
Jun 22, 2026 39193256K ACTIVE CLASS - 2 FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS 39141081N, FILE A CERTIFICATE OF CORRECTION $1,250 $1,250 Sep 4, 2026
Jun 22, 2026 39193258Y ACTIVE CLASS - 2 FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS 39141080L, FILE A CERTIFICATE OF CORRECTION $1,250 $1,250 Sep 4, 2026
Jun 22, 2026 39193257M ACTIVE CLASS - 2 FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS 39141079Y, FILE A CERTIFICATE OF CORRECTION $1,250 $1,250 Sep 4, 2026
Nov 17, 2025 35726150X ACTIVE CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTED:AS PERINSPECTION AND PROPERTY REVIEW.THE PROPERTY OWN... $1,250 $1,250 May 29, 2026
Apr 8, 2025 37035107K ACTIVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... $10,000 $10,000 Aug 1, 2025
Mar 24, 2025 39142578N ACTIVE CLASS - 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO... $6,250 $6,250 May 30, 2025
Mar 11, 2025 39141081N ACTIVE CLASS - 1 FAILURE TO OBEY A VACATE ORDER FROM THE COMMISSIONER PER 28-207.4. NOTED: AT TIME OF INSPECTION - APT 4J WAS OBSERVED... $10,000 $10,000 Mar 9, 2026
Mar 11, 2025 39141079Y ACTIVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - OBSERVED ELECTRICAL CORD HANGIN... $2,500 $2,500 Mar 9, 2026
Mar 11, 2025 39141080L ACTIVE CLASS - 1 REMOVED OR DEFACED A WRITTEN POSTED VACATE ORDER. NOTED: AT TIME OF INSPECTION - PVO POSTED 1/16/2025 & VACATE STICKE... $5,000 $5,000 Mar 9, 2026
Mar 4, 2025 35716750K ACTIVE CLASS - 2 FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #2 SOUTH, #4 ... $2,500 $2,500 May 16, 2025
Mar 4, 2025 35716751M ACTIVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAYS.-NOTE: AT TIME OF INSPECTION, I OBSERVED AT EXP #1 EAST, #2 SOUTH, #... $1,250 $1,250 Mar 9, 2026
Feb 25, 2025 37033504P RESOLVE CLASS - 2 1RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103... $0 $0 Mar 9, 2026
Dec 30, 2024 39135627P RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8; 27-371... $312 $312 Sep 15, 2025
Dec 30, 2024 39135625L ACTIVE CLASS - 1 CONTRARY TO DOB/OFFICIAL RECORDS: APT 4J WAS OBSERVED CONVERTED FROM A 1 TO 4 BDRM UNIT - OCCUPIED AS SRO'S W/O SUFFI... $625 $625 Sep 15, 2025
Dec 30, 2024 39135628R ACTIVE CLASS - 2 W/O A PERMIT. NOTED: AT TIME OF INSPECTION - FULL HEIGHT PARTITION WALLS ERECTED TO CREATE ADDL'T BDRMS. ELECTRICAL W... $625 $0 Sep 15, 2025
Dec 30, 2024 39135626N ACTIVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - 2ND EGRESS/EMERGENCY EXIT FOR A... $312 $312 Sep 15, 2025
Jul 17, 2024 35681842K RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING FACADE AND APPURTENANCES. OBSERVED DAMAGED BRICK WORK AT PARAPET LEVEL AT THE ENTRANCE O... $2,500 $2,500 Aug 11, 2025
Aug 2, 2013 35009945H RESOLVE CLASS - 1 BC331463. LIFELINES,TIEBACKS,AND SUSPENSION ROPES SHALL EACH BE ATTACHED TO A DIFFERENT POINT OF ANCHORAGE. LIFELINE ... $1,600 $0 Oct 25, 2013
Jul 12, 2010 38211359N RESOLVE CLASS - 2 08V1,15B10,12Q03,98BB5,68B11,69M7,30Q3,100B11. 100- A17.3-2002 AMENDEDBY CHPT ALT 3 3.3.2 $0 $0 Sep 3, 2010
Jun 15, 2009 38203966P RESOLVE CLASS - 2 100M07. 100M07 FAILURE TO POST ELEVATOR WORK PERMIT AS REQUIRED. $800 $0 Aug 7, 2009
Aug 19, 2008 38190338Y RESOLVE CLASS - 2 32L10,5L10,16L10,16T7,16L10,2L10,40P7. 32/L CAR GUIDE SHOES NEED REPAIR 5/L CAR DOOR NEED ADJUSTMENT GAP B/W DOOR AND... $2,500 $0 Oct 17, 2008
Aug 19, 2008 38190339X RESOLVE CLASS - 2 32L10,16L10,8U1,16T7,40P7. 32/L CAR GUIDE SHOES NEED REPAIR 16/L ALL HOISTWAY DOOR CHECKS NEED REPAIR. 8/U LEVELING I... $500 $0 Oct 17, 2008
Apr 23, 2008 38183790P RESOLVE Non-Hazardous 85U05.86U05.40D06.66O02 40 PROVIDE LOCK FOR DOOR $350 $0 Jun 13, 2008
Apr 23, 2008 38183791R RESOLVE Non-Hazardous 85U05.86U05.40D06.51K10.12Q03.44H10.66O02. 44H10 GOV BEARING $350 $0 Jun 13, 2008
Jul 3, 2006 38159922H RESOLVE Non-Hazardous 12Q07/66O02. 12-Q-07-PROVIDE PROPER GUARD ON ELEVATOR LIGHT. INSIDE ELEVATOR. 66-O-02 CLEAN PIT. $180 $0 Aug 18, 2006
Jul 3, 2006 38159921X RESOLVE Non-Hazardous 21L10/12Q07/66O02. (21-L-10)REPAIR FROZEN 6TH FLR INTERLOCK. (12-Q-07)PROVIDE PROPER LIGHT GUARD ON ELEVATOR LIGHTING... $180 $0 Aug 18, 2006