Maintenance code violations
1099 Carroll Place, Bronx • Block 02462 • Lot 0033
145 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| May 10, 2019 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 4E, 4th STORY, 2nd... | 4E | Jun 14, 2019 |
| May 10, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE 4th ROOM FROM NORTH ... | 4E | Aug 13, 2019 |
| May 10, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING I... | 4E | Jun 14, 2019 |
| May 10, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING I... | 4E | Aug 13, 2019 |
| May 10, 2019 | C | DEFECT LETTER ISSUED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STO... | 4E | May 31, 2019 |
| May 10, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WOOD CABINETS DOOR KNOBS AT SOUTH WALL IN THE KITCHEN LOCATED AT APT ... | 4E | Aug 13, 2019 |
| May 10, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT... | 4E | Aug 13, 2019 |
| Oct 22, 2018 | A | VIOLATION CLOSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Jan 25, 2019 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Jun 21, 2018 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WASH BASIN IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 6L, 6th ST... | 6L | Jul 26, 2018 |
| Jun 21, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE IN THE 2nd BATHRO... | 6L | Jul 26, 2018 |
| Jun 21, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL AT BATHTUB IN THE 2... | 6L | Jul 26, 2018 |
| Jun 21, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL AT BATHTUB IN THE 1... | 6L | Jul 26, 2018 |
| Mar 29, 2018 | A | VIOLATION CLOSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Jul 2, 2018 |
| Mar 29, 2018 | B | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE EN... | 6H | May 3, 2018 |
| Jan 25, 2018 | A | NOT COMPLIED WITH | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE AND OR REGLAZE PORCELIN FINISH AT BATHTUB IN THE BATHROOM LOCATED ... | 3D | Apr 30, 2018 |
| Jan 25, 2018 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT RISER IN THE BATHROOM LOCATED AT APT 3D, 3rd STOR... | 3D | Mar 1, 2018 |
| Jan 25, 2018 | C | VIOLATION CLOSED | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Feb 2, 2018 |
| Jan 25, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WALL... | 4E | Mar 1, 2018 |
| Jan 25, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WALL... | 4E | Mar 1, 2018 |
| Jan 25, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE... | 3D | Mar 1, 2018 |
| Jun 13, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXCESSIVE HOT WATER CONSISTING OF TEMPERATURE ABOVE... | 1D | Jun 21, 2017 |
| Apr 19, 2017 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2G, 2nd STORY, ... | 2G | Apr 18, 2017 |
| Apr 19, 2017 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR TO BOILER ROOM. AT BASEMENT | — | Apr 27, 2017 |
| Apr 19, 2017 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, ... | 5J | Apr 18, 2017 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| May 2, 2016 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILINGS ,WALLS ,DOORS A... | 1B | Aug 5, 2016 |
| Nov 2, 2015 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 1B | Feb 5, 2016 |
| Nov 2, 2015 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1s... | 1B | Dec 7, 2015 |
| Nov 2, 2015 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT THE UPPER AND LOWER WINDOW SASHES IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMEN... | 1B | Feb 5, 2016 |
| Oct 15, 2015 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE PIPE UNDER THE SINK IN THE KITCHEN LOCATED AT A... | 1B | Nov 19, 2015 |
| Oct 15, 2015 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2... | 1B | Nov 19, 2015 |
| Oct 15, 2015 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE UPPER WINDOW SASH IN THE 2nd ROOM FROM NORTH A... | 1B | Oct 23, 2015 |
| Oct 6, 2015 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE UPPER WINDOW PANE IN THE 2nd ROOM FROM NORTH LOCATED AT A... | 1B | Nov 10, 2015 |
| — | I | VIOLATION DISMISSED | SECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CO... | — | — |
| Mar 9, 2015 | A | VIOLATION CLOSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Jun 12, 2015 |
| Nov 21, 2014 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE UPPER WINDOW PANE IN THE 2nd ROOM FROM NORTH LOCATED AT A... | 1B | Feb 24, 2015 |
| Nov 12, 2014 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SOUTH WALL AT BULKHEAD 6TH STY WEST ... | — | Dec 17, 2014 |
| Nov 12, 2014 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT SOUTH WALL AT BULKHEAD 6TH S... | — | Feb 15, 2015 |
| Nov 12, 2014 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROVIDE ( IN THE EVENT OF A POWER OUTAGE ) A HEAVY DUTY KEY OPERATED LOCK AND LATCH SET AT VESTIBU... | — | Dec 17, 2014 |
| Nov 12, 2014 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF A ELECTROMAGNETIC LOCKSET INSTALLED ON THE VESTIB... | — | Nov 20, 2014 |
| Nov 12, 2014 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING 6TH STY PUBLIC HALL ... | — | Feb 15, 2015 |
| Nov 12, 2014 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING 6... | — | Dec 17, 2014 |
| Oct 10, 2014 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER WINDOW SASH IN THE 4th ROOM FROM NO... | 6L | Nov 14, 2014 |
| Oct 10, 2014 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN... | 6L | Nov 14, 2014 |
| Sep 24, 2014 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 5J | Oct 29, 2014 |
| Sep 24, 2014 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 5J | Oct 29, 2014 |
| Sep 24, 2014 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE 1st ROOM FROM E... | 5J | Oct 29, 2014 |
| Sep 24, 2014 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM NO... | 5J | Dec 28, 2014 |
| Sep 24, 2014 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RISER FROM NORTH AT EAST WALL IN THE KITCH... | 5J | Dec 28, 2014 |