1109 Carroll Place, Bronx • Block 02462 • Lot 0039
14 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 17, 2026 | 39177423Z | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REM... | $625 | $0 | Apr 10, 2026 |
| Feb 17, 2026 | 39177425M | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REM... | $625 | $0 | Apr 10, 2026 |
| Feb 17, 2026 | 39177424K | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REM... | $625 | $0 | Apr 10, 2026 |
| Oct 15, 2025 | 39546733P | RESOLVE | CLASS - 2 | STOP ALL FACADE OPERATIONS AND USE OF SIDEWALK SHED AT EXPOSURE 3. I OBSERVED ELECTRICAL / UTILITY CABLES NOT PROTECT... | $5,000 | $5,000 | Dec 3, 2026 |
| Oct 15, 2025 | 39545994Z | RESOLVE | CLASS - 2 | STOP ALL FACADE OPERATIONS AND USE OF SIDEWALK SHED AT EXPOSURE 3. I OBSERVED ELECTRICAL / UTILITY CABLES NOT PROTECT... | $0 | $0 | Dec 19, 2025 |
| Apr 2, 2024 | 38275575K | ACTIVE | CLASS - 1 | 39-L-10, 99-BB-5. 39-L-10=TOP OF CAR TAPE ELECTRIC-UNIT DEFECTIVE AFFECTING FLOOR STOPS AND CAUSING THE ELEVATOR TO O... | $1,250 | $0 | May 10, 2024 |
| Feb 13, 2020 | 37018013P | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Oct 2, 2020 |
| Nov 15, 2019 | 37016927M | ACTIVE | CLASS - 2 | SEC. 27-929.1 A.C.27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRIKLERS & FILE A FINA... | $1,250 | $0 | Jan 3, 2020 |
| Jun 25, 2019 | 35437425P | ACTIVE | CLASS - 2 | CONST EQUIPMENT-SIDEWALK SHED EXPIRE PERMIT @THE TIME OF INSPECTION OBSERVED A HEAVY DUTY SIDEWALK SHED ON 1188 GRAND... | $1,250 | $1,250 | Aug 16, 2019 |
| Nov 9, 2016 | 38250206Y | RESOLVE | CLASS - 2 | 88I11,100B10. (88I)LEFT HAND RAIL. (100B)LIGHTS BETWEEN STEPS TOP & BOTTOM. | $0 | $0 | Jan 20, 2017 |
| Nov 9, 2016 | 38250205M | RESOLVE | CLASS - 2 | 88I11. REPLACE LEFT HAND RAIL. | $0 | $0 | Jan 20, 2017 |
| Oct 3, 2014 | 35100605Z | RESOLVE | CLASS - 1 | 3314.6.1 PARTIAL SWO ISSUED FOR SUSPENDED SCAFFOLD PURSUANT 28-207.2 &POSTED ON PREMISES. FAILED TO PROVIDE SAFE POIN... | $1,600 | $0 | Dec 5, 2014 |
| Sep 25, 2008 | 36000021N | ACTIVE | CLASS - 1 | FAILURE TO FILE AFFIDAVITS AND/OR COMPLY W/OTHER REQUIREMENTS SET FORTH FOR PHOTOLUMINESCENT EXIT PATH MARKING. REMED... | $0 | $0 | Dec 19, 2008 |
| Oct 1, 1993 | 34097898K | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. EXPIRED PERMIT #2002075 EQ FN (FENCE) REMEDY: RENEW FENCE PERMIT | $1,000 | $0 | Nov 12, 1993 |