Maintenance code violations
1235 Grand Concourse, Bronx • Block 02464 • Lot 0023
966 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Mar 27, 2019 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 104 | Apr 24, 2019 |
| Mar 27, 2019 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 104 | Apr 24, 2019 |
| Mar 27, 2019 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 104 | Apr 24, 2019 |
| Mar 27, 2019 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 104 | Apr 24, 2019 |
| Mar 27, 2019 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 104 | Apr 24, 2019 |
| Mar 26, 2019 | B | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT APARTMENT ENTRANCE LOCATED AT APT 620, 6th STORY,... | 620 | Apr 30, 2019 |
| Nov 5, 2018 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 115, 1st STORY, 2nd APARTMENT FROM NOR... | 115 | Dec 10, 2018 |
| Nov 5, 2018 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK ASSEMBBLY AT BUILDING ENTRANCE DOOR , 1st STORY | — | Nov 13, 2018 |
| Nov 5, 2018 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 115, ... | 115 | Nov 13, 2018 |
| Nov 5, 2018 | B | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR P... | 115 | Dec 10, 2018 |
| Nov 5, 2018 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 115, 1st STORY, 2n... | 115 | Dec 10, 2018 |
| Sep 4, 2018 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 422 | Oct 2, 2018 |
| Sep 4, 2018 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 422 | Dec 8, 2018 |
| Sep 4, 2018 | A | VIOLATION DISMISSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT EAST WALL, WEST WALL IN TH... | 422 | Dec 8, 2018 |
| Sep 4, 2018 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL, WEST WALL IN ... | 422 | Dec 8, 2018 |
| Sep 4, 2018 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 422 | Oct 2, 2018 |
| Sep 4, 2018 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALL... | 422 | Oct 9, 2018 |
| Aug 27, 2018 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 620, 6th ... | 620 | Sep 4, 2018 |
| Aug 23, 2018 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 418, 4th STORY, 1st APARTMENT FROM WES... | 418 | Sep 27, 2018 |
| Aug 23, 2018 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 418, 4th STORY, 1s... | 418 | Sep 27, 2018 |
| Aug 23, 2018 | C | VIOLATION DISMISSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 418 | Sep 20, 2018 |
| Aug 23, 2018 | B | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS : DOOR IN THE ENTRANCE LOCATED AT APT 111, 1st STORY... | 111 | Sep 27, 2018 |
| Aug 23, 2018 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES THE RANGE IN THE KITCHEN LOCATED AT APT 111, 1st... | 111 | Aug 31, 2018 |
| Aug 23, 2018 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 418 | Nov 26, 2018 |
| Aug 23, 2018 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, WEST WALL IN THE B... | 418 | Sep 27, 2018 |
| Aug 23, 2018 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES THE RANGE IN THE KITCHEN LOCATED AT APT 418, 4th... | 418 | Aug 31, 2018 |
| Jun 25, 2018 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 210, ... | 210 | Jul 3, 2018 |
| May 4, 2018 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 118, 1st ... | 118 | May 12, 2018 |
| Apr 10, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL-BUZZER/INTERCOM FROM BUILDING VESTIBULE TO THE KITCHE... | 620 | May 15, 2018 |
| Apr 10, 2018 | B | NOT COMPLIED WITH | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 620, 6th STORY, 1... | 620 | May 15, 2018 |
| Apr 9, 2018 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 104, ... | 104 | Apr 17, 2018 |
| Apr 6, 2018 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES ... LOCATED AT APT 620, 6th STORY, 1st APARTMENT... | 620 | Apr 14, 2018 |
| Apr 6, 2018 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES ... LOCATED AT APT 212, 2nd STORY, 1st APARTMENT... | 212 | Apr 14, 2018 |
| Jun 27, 2017 | A | VIOLATION DISMISSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Sep 30, 2017 |
| May 26, 2017 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR AT CLOSET IN THE 3rd ROOM FROM EAST AT NORTH LOCATED ... | 219 | Jun 30, 2017 |
| May 26, 2017 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR AT CLOSET IN THE 1st ROOM FROM EAST AT SOUTH LOCATED... | 219 | Jun 30, 2017 |
| Nov 7, 2016 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CLOSET DOOR DOOR IN THE 4th ROOM FRO... | 222 | Dec 12, 2016 |
| Nov 7, 2016 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT ROOM DOOR LEADING TO... | 222 | Nov 15, 2016 |
| Nov 7, 2016 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 222 | Dec 12, 2016 |
| Nov 7, 2016 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL CEILING LIGHT FIXTURE IN THE FOYER LOCATED AT A... | 222 | Dec 12, 2016 |
| Nov 7, 2016 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE KITCHEN L... | 222 | Dec 12, 2016 |
| Nov 7, 2016 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE FOYER LOC... | 222 | Dec 12, 2016 |
| Nov 7, 2016 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL... | 222 | Dec 12, 2016 |
| Nov 7, 2016 | B | VIOLATION DISMISSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AND MILDEW AT CEILING AND WES... | 222 | Dec 12, 2016 |
| Nov 7, 2016 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE 4th ROOM ... | 222 | Dec 12, 2016 |
| Nov 3, 2016 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH WALL IN THE B... | 222 | Dec 8, 2016 |
| Nov 3, 2016 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 222 | Dec 8, 2016 |
| Nov 3, 2016 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 222, 2nd STORY, 2nd APARTMENT FROM SOU... | 222 | Dec 8, 2016 |
| Nov 3, 2016 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FRO... | 222 | Dec 8, 2016 |
| Nov 3, 2016 | A | VIOLATION DISMISSED | § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ... IN THE BATHROOM LO... | 222 | Feb 6, 2017 |