Skip to content

ECB violations

716-726 Gerard Avenue, Bronx • Block 02473 • Lot 0048

62 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Apr 20, 2026 37036842L ACTIVE CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FA... $1,250 $1,250 Aug 21, 2026
Mar 9, 2026 39179744Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED EGRESS EXIT DOOR PARTIALLY OBST... $0 $0 May 15, 2026
Mar 9, 2026 39179745K RESOLVE CLASS - 1 AT TIME OF INSPECTION EXIT DOOR WITH IMPROPER HARDWARE. DOOR HAVE A PUSH BAR BUT IN ADDITION ABOVE THE PUSH BAR THEY ... $2,500 $0 May 15, 2026
Feb 4, 2026 39175931X RESOLVE CLASS - 2 MISALINGED CAB MIRROR. INAUDIBLE ALARM BELL. PROVIDE DESIGNATED LOBBY BRAILLE TAGS. ADJUST CAR DOOR ECCENTRICS. OPERA... $1,592 $1,592 Feb 11, 2027
Feb 4, 2026 39175930Y ACTIVE CLASS - 2 MISALINGED CAB MIRROR. PROVIDE DESIGNATED LOBBY BRAILLE TAGS. MAIN LINE CAN BE OPENED WHEN POWER ON. UNREADBLE MAIN L... $625 $625 Sep 18, 2026
Oct 24, 2025 35685735N RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. USE OF PROHIBITED DOOR/OR HARDWARES PER BC 1008.1.8; 27-371(J)... $2,500 $2,500 Dec 18, 2026
Aug 21, 2025 39158027N RESOLVE CLASS - 1 CEASE USE ITEM:DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO ... $1,250 $0 Oct 31, 2025
Jul 17, 2025 39154065X RESOLVE CLASS - 1 CLASS 1:(CU)FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER, DOOR ZONE RESTRICTOR OF ELEVATOR INOPERATIVE,REPAI... $1,250 $0 Oct 3, 2025
Jun 26, 2025 39152119N RESOLVE CLASS - 2 RTS, CLASS 2 VIOLATION ISSUED, UPON ON INSPECTION DEVICE IS FOUND TO BE OUT -OF- SERVICE, AS PER 1 RCNY 11-02 , RESTO... $0 $0 Sep 5, 2025
May 27, 2025 39148985H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REM... $1,250 $0 Aug 1, 2025
Dec 19, 2024 39133385M RESOLVE CLASS - 2 UNGUARDED CAB LIGHTING. INOPERATIVE CAR PHONE. MISSING IN CASE OF FIRE SIGNS. MISALIGNED CAB MIRROR. OPERATOR COVER M... $312 $0 Apr 4, 2025
Aug 22, 2024 35683717K ACTIVE CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER#35685488P REQUESTING OWNER TO REMOVE FIRE ESCAPE OBSTRUCTIO... $1,250 $0 Apr 4, 2025
Aug 22, 2024 35683718M ACTIVE CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.AT TIMEOF INSPECTION OF EXPOSURE#1 & 4(EAST AND NORTH ... $1,250 $0 Apr 4, 2025
Jul 18, 2024 35685488P ACTIVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE: OBSERVED OBSTRUCTION ON FIRE ESCAPE ON 4TH AND 6TH FLOOR AT EX... $625 $0 Nov 15, 2024
Jul 11, 2024 35684022Z ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS FACADE AND APPURTENANCES: OBSERVED CRACK DETERIORATION AT ALL EXPOSURES/V... $1,250 $0 Nov 1, 2024
Apr 19, 2024 35681779R ACTIVE CLASS - 1 FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES.NOTE:ATTIME OF INSPECTION,I OBSERVED STEP CRACK BRICK ... $2,500 $0 Nov 22, 2024
Apr 19, 2024 35681780Y ACTIVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY NOTE:AT TIME OF INSPECTION,I OBSERVED AT EXPOSURE#1 EAST COURTYARD ST... $1,250 $0 Nov 22, 2024
Apr 10, 2024 35683616L ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS FACADE AND APPURTENANCES: OBSERVED CRACK DETERIORATION AT ALL EXPOSURES/V... $1,250 $0 Sep 20, 2024
Jun 7, 2023 39517557M RESOLVE CLASS - 2 I OBSERVED EXISTING 6 STORY OCCUPIED BUILDING WITH EXPIRED PERMIT#-210058319 UNDER ALT TYPE 3, JOB FOUND 100% COMPLET... $0 $0 Aug 18, 2023
Nov 9, 2020 39031750Y RESOLVE CLASS - 2 PHONE INOPERATIVE. NO ACCESS TO MACHINE ROOM, KEYS MUST BE AVAILABLE DURING BUSINESS HOURS. $0 $0 Feb 12, 2021
Jun 20, 2017 32091011K RESOLVE CLASS - 2 B254,36 (36)AS PER CLASS 254-36 BOILER NOT REGISTERED AS PER DOB RECORDS,CORRECT ALL VIOLATING CONDITIONS AND SUBMIT ... $0 $0 Aug 10, 2017
Jun 1, 2017 38255545L RESOLVE CLASS - 2 02X10,61T15,60B07,57B07,100X10,100X10,39X10,26D06,37T15,52M07,97O02. 02-REPAIR IN CARE PHONE; 61-UNLABEL MAINLINE; 60... $0 $0 Aug 4, 2017
Jun 1, 2017 38255533Y RESOLVE CLASS - 2 02X10;56Y13;100X10;57B11;37B07;37X10;70O02:REPAIR IN CAR PHONE,SEAL MACHINE,REPAIR CALL CANCEL BUTTON,EXPIRED FIRE EX... $0 $0 Jul 21, 2017
Nov 14, 2013 35037716M RESOLVE CLASS - 1 UNAPPROVED/UNSAFE/UNSTABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE.THE ENTIRE AP... $0 $0 Jan 17, 2014
Nov 14, 2013 35037717Y RESOLVE CLASS - 1 FAILURE TO GROUND ELECTRICAL SYSTEMS. BSMT SERVICE GROUND CONDUCTOR: NO WATER MAIN GROUND PROVIDED. RMDY: PROVIDE GRO... $0 $0 Jan 17, 2014
Nov 14, 2013 35038089R RESOLVE CLASS - 1 ELECTRICAL WORK W/O A PERMIT. ELEVATOR MOTOR ROOM: MOTOR RECEPTACLE OUTLETS (GFCI) LIGHTS,SWITCHES,CONTROL PANEL. SEE... $0 $0 Apr 4, 2014
Nov 14, 2013 35037764R RESOLVE CLASS - 1 ELECTRICAL WORK W/O A PERMIT. ELEVATOR MOTOR ROOM: MOTOR,ELEVATOR CON TROLLER,GECI OUTLETS LIGHTING FIXTURES. RMDY: O... $800 $0 Jan 31, 2014
Feb 7, 2013 38225531N RESOLVE CLASS - 2 97X10,100I10. 97-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNERSERVICE EQUIPMENT ELEVATOR PER BC3001.2;27-987.... $0 $0 Mar 29, 2013
Sep 16, 2009 38206199R RESOLVE CLASS - 2 09I10.05I11.70O2.81M7.98BB5 05I11 REPLACEMENT DOOR VISION GLASS 39Q3 IINSTALL GUARD FOR LIGHT TOP OF CAR 77Q3 INSTALL... $250 $0 Nov 6, 2009
Apr 25, 2007 34575029M RESOLVE Non-Hazardous FAILURE TO MAINTAIN BLDG INTERIOR.BULKHEAD ROOF DOOR IS BROKEN & OFF HINGES.REMEDY:REPAIR EXIT DOOR TO ROOF. $350 $0 Jul 20, 2007
Apr 23, 2007 34558596Y RESOLVE Non-Hazardous SIGNS AT ELEVATORS LANDING MISSING OR DEFECTIVE. NOTED: NO SIGNAGE AT ELEVATOR LANDINGS AS REQUIRED. REMEDY: INSTALL ... $200 $0 Jul 20, 2007
Apr 23, 2007 34558597X RESOLVE Non-Hazardous FLR NUMBERING SIGNS MISSING &/OR DEFECTIVE. NOTED: NO FLR # SIGNAGE INBOTH STAIRWELLS EXCEPT FOR 2 & 3 FLRS. REMEDY: ... $200 $0 Jul 20, 2007
Apr 23, 2007 34558595M ACTIVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL. NOTED: IMPROPERLY INSTALLED WINDOW MOUNTED A/C UNITS AT NUMEROUS LOCATIONS. B... $800 $0 Jul 20, 2007
Dec 15, 2006 38162162L RESOLVE Non-Hazardous 11 I 10/38 O 2/85 BB 5/. 11-I-10-MAKE REPAIRS TO CAR STATION,DAMAGED EMG,LIGHTS & FIRE RECALL LIGHT.38-O-2-CLEAN CAR ... $350 $0 Feb 2, 2007
Sep 7, 2006 34530834X RESOLVE Hazardous USE OF ILLEGAL HARDWARE.THE EXIT DOOR ON GERARD AVENUE HAS A SLIDE BOLT WITH EYE AND A PADLOCK. REMEDY: REMOVE ILLEGA... $0 $0 Mar 2, 2007
Jan 4, 2006 38157051M RESOLVE Non-Hazardous 13I10/85BB05/40T07/84W07/84T07/(13-I-10)EMERGENCY LIGHTING DAMAGED.(85-BB-05)5YR TEST TAG EXPIRED(40-T-07)PROVIDE MOT... $350 $0 Aug 24, 2007
Jan 4, 2006 38157052Y RESOLVE Non-Hazardous 85BB05/83X10/(85-BB-05)5YR TEST TAG.EXPIRED.(83-X-10)RETURN ELEVATOR TO SERVICE FOR PROPER INSP. BY D.O.B. $350 $0 Aug 24, 2007
Dec 22, 2005 38155917P RESOLVE Non-Hazardous 85-BB-05/66-O-02/25-D-06/08-V-10. 08-V-10 ADJUST FLOOR STOP WEW NEED. $2,500 $0 Jul 21, 2006
Dec 22, 2005 38155916N RESOLVE Non-Hazardous 83-P-16 RESTORE ELEVATOR BACK TO SERVICE SO THAT A PROPER INSPECTION CAN BE DONE BY THIS DEPARTMENT. $2,500 $0 Jul 21, 2006
Dec 26, 2000 38110381R RESOLVE Non-Hazardous 5J11,15L11,23U16,75U5,35Y2,50Y11,57O2,62K12.5-TOO MUCH GAP TO POST.15-SLAMS 1 + 5FL $350 $0 Mar 5, 2004
Nov 21, 2000 34270009H RESOLVE Hazardous HAZARDOUS WORK WITHOUT PERMIT. WORK NOTED: ENTRANCE ON GERARD AVE SIDE OF PREMISES SEALED WITH BRICK. REMEDY: OBTAIN ... $800 $0 Jan 12, 2001
Oct 30, 2000 38108954M RESOLVE Non-Hazardous 15L11,18D6,22Y2,22L6,23U16,75U5,62K10.15-SLAMS 1,3,+4FL.18-2FL KEEPER.22Y-CAR TOP.22-SECURE TO CODE. $0 $0 Dec 22, 2000
Aug 10, 1999 38089419J RESOLVE Non-Hazardous 15M 73# HATLH DOOR GLAS SERVICE SO COMPLETE INSPECTION 73 RESTORE MADE BY THIS DEPARTMENT $2,500 $0 Oct 8, 1999
Aug 10, 1999 38089420R RESOLVE Non-Hazardous 05M 60I 03Q 30Q 05 M 07 PROVIDE CAB DOOR DOOR GLASS 30 Q 03 COVER MISSING 60 I 11 PROVIDE CTW SPRING BUFFER 6TH SHAFT... $2,500 $0 Oct 8, 1999
Mar 6, 1998 38071567X RESOLVE Non-Hazardous 14M33P47H62M 62 TOE GUARD. $350 $0 May 22, 1998
Mar 6, 1998 38071568H RESOLVE Non-Hazardous 73X 73-RESTORE ELEVATOR SERVICE SO PROPER INSPECTION CAN BE MADE BY THIS DEPT. $350 $0 May 22, 1998
Aug 28, 1997 38063179Y RESOLVE Non-Hazardous 73X75U #73 RESTORE DEVICE BACK TO SERVICE SO A PROPER INSPECTION COULDBE MADE. $0 $0 Oct 24, 1997
Aug 28, 1997 38063178M RESOLVE Non-Hazardous 03I28H46H39H36D47K33Z15J03O31Q50Y20L10I75U03I 03 VISION GLASS BROKEN ON CAR DOOR #33 SKYLIGHT GLASS BROKEN #03 CAR TO... $0 $0 Oct 24, 1997
Jul 29, 1997 38062502K RESOLVE Non-Hazardous 14M17I05I11Q24L33I75U $1,000 $0 Aug 13, 1999
Jul 12, 1997 38059864K RESOLVE Non-Hazardous 50Y,08X,75U,03O,57O,15J,31Q,18Q,32Q,10I,20L,33D,08V,13L, 08-5TH FLOOR NOT WORKING ELEVATOR NOT GOING TO 5TH FLOOR 03-... $200 $0 Aug 25, 1999