ECB violations
1080 Anderson Avenue, Bronx • Block 02505 • Lot 0006
40 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 29, 2025 | 35717687L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTED:AT THE TIME OF INSPECTION OBSERVED AT EXP #3(EA... | $2,500 | $0 | Mar 13, 2026 |
| Oct 15, 2025 | 35717790J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING FACADE WALLS AND APPURTENANCES.NOTE:AT THE TIME OF INSPECTION I OBSERVED AT EX#4 SOUTH E... | $1,250 | $1,250 | Jul 24, 2026 |
| Apr 29, 2024 | 39528081J | RESOLVE | CLASS - 2 | AT A 6 STORY OCCUPIED BUILDING. I NOTICED SIDEWALK SHED HAS MISSING A INFORMATION PANEL ON PARAPET. THIS CREATES A UN... | $1,280 | $0 | Apr 1, 2025 |
| Dec 2, 2022 | 37024281M | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE9A REPORT OF CRITICAL EXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTEN... | $625 | $0 | Mar 3, 2023 |
| Nov 2, 2022 | 35664561J | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG FACADE&APPURTENANCES.OBSERVED DAMAGED/OPEN MORTAR JOINTS@PARAPET LEVEL&VARIOUS LOCA... | $1,250 | $0 | Feb 3, 2023 |
| Sep 9, 2022 | 39069726H | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED RECURRING, DLM IMPROPER INSTALLED ON DEVICE. NO FIREMAN SERVICE PRESENTED IN CONTROLLER INST... | $3,125 | $0 | Dec 2, 2022 |
| Aug 4, 2022 | 39067393J | RESOLVE | CLASS - 1 | CLASS 1 DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN'S SERVICE PRESENT IN THE CONTROLLER. INSTALL FIREMAN'S SE... | $1,563 | $0 | May 12, 2023 |
| Jun 8, 2022 | 39063720J | RESOLVE | CLASS - 1 | CLASS 1 RECURRING VIOLATION ISSUED DLM IMPROPERLY INSTALLED ON THIS DEVOICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER... | $1,250 | $0 | Apr 24, 2023 |
| May 24, 2022 | 39062799R | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION RECURRING ISSUED , DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLE... | $1,563 | $0 | Apr 18, 2023 |
| Jan 19, 2022 | 39054579P | RESOLVE | CLASS - 1 | CLASS 1 ITEM, DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER. INSTALL FIREMAN SERV... | $3,125 | $0 | Dec 7, 2022 |
| Sep 9, 2021 | 39047347K | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED, NO FIRE SERVICE INSTALLED IN THIS CONTROLLER AS PER CODE DLM AS TO WORK ON PHASE 1&2 IN THE... | $3,125 | -$3,125 | Dec 17, 2021 |
| Jul 27, 2021 | 39045016R | RESOLVE | CLASS - 1 | THE COMMISSIONER ORDERS THAT YOU TIMELY CORRECT THESE CONDITIONS AND FILE A CERTIFICATE OF SUCH CORRECTION. SEE 1RCNY... | $0 | $0 | Jan 11, 2023 |
| Apr 26, 2021 | 39040007M | RESOLVE | CLASS - 2 | RESTORE SERVICE TO SECOND FLOOR LANDING, DOOR BOLTED SHUT AND ELEVATOR DOESN'T STOP THERE. PROVIDE FIRE SERVICE AS PE... | $3,250 | $0 | Dec 3, 2021 |
| Feb 16, 2021 | 39036240R | RESOLVE | CLASS - 2 | PROVIDE FIRE SERVICE ON THIS DEVICE AS PER 2.27.3.3.6 OF APPENDIX K OF THE 2014 NYCBC. REMEDY: OBTAIN PERMIT, INSTALL... | $1,562 | -$1,562 | May 21, 2021 |
| Jan 7, 2021 | 39034482K | RESOLVE | CLASS - 2 | CLASS 2 VIOLATION ISSUED. ITEM, AS TO PERMIT ISSUED AND WORK COMPLETED, AS PER SEC 2.27.3.3.6 OF THE NYCBC, FIREMAN S... | $625 | $0 | Mar 5, 2021 |
| Oct 27, 2020 | 39031123P | RESOLVE | CLASS - 1 | DOOR RESTRICTOR ALTERED (CEASE USE). TOP OF CAR PLANK SWITCH NOT TIED TO GOVERNOR ROPE. | $1,250 | $0 | Dec 18, 2020 |
| Sep 11, 2020 | 39028524Z | RESOLVE | CLASS - 2 | ADJUST FLOOR HEIGHTS. DOOR FOR OVERHEAD DOESN'T CLOSE. | $1,562 | -$1,562 | Dec 4, 2020 |
| Feb 3, 2020 | 38272013P | RESOLVE | CLASS - 1 | 42M07, 08V01, 56Y13: 42-M-07 NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF... | $1,250 | $0 | Sep 25, 2020 |
| Oct 5, 2019 | 38271858M | RESOLVE | CLASS - 2 | 21-B-10,52-M-07,58-H-10,05-J-10=(1)21-B-# 5 FLOOR HOISTWAY DOOR BRAKE CONTACT WHEN PULL ON (2) 52-M-# PROVIDE TAG (3)... | $655 | $0 | Nov 29, 2019 |
| Apr 24, 2019 | 38269417Y | RESOLVE | CLASS - 1 | CEASE USE:05.M.07,(C/U)08.V.01,02.X.10,23.I.10,25.M.07,56.Y.13,68.B.07,59.BB.07,42.M.07,42.B.09,60.Q.03,61.B.09,(R/C)... | $3,125 | $0 | Nov 19, 2019 |
| Oct 14, 2018 | 38264437Z | RESOLVE | CLASS - 2 | 32H1,58H10,100D6/9; 70O2. 32-GUIDESHOES WORN ADJUST; 58-BEARINGS WORN REPAIR; 100-MISCELLANEOUS UNSECURED WIRE IN SHA... | $625 | $0 | May 3, 2019 |
| Nov 14, 2016 | 38251254N | RESOLVE | CLASS - 2 | 2M7,32H10,52B14,70OQ,71X10. 2-OUTSIDE COMMUNIATION CAR PHONE MISSING PROVIDE; 32-GUIDESHOES WORN REPAIR; 52-HOIST ROP... | $0 | $0 | Jan 6, 2017 |
| Sep 29, 2016 | 38246212Z | RESOLVE | CLASS - 1 | CEASE USE. 5D10. CAB DOOR HAS A GAP WHEN FULLY CLOSE (REPAIR). | $1,000 | $0 | Feb 10, 2017 |
| Feb 27, 2016 | 38240598N | RESOLVE | CLASS - 2 | 02M07,21L10,70O02,71M07,70M07,37X07,42U11,68B07. 02-COMMUNICATION IN CAR MISSING PROVIDE; 21-INTERLOCK IN BSMT NO ACC... | $0 | $0 | Apr 15, 2016 |
| Aug 16, 2014 | 38232469R | RESOLVE | CLASS - 1 | C/U 21D06,61R09,08J01. 21D06-6TH FLR INTERLOCK LOOSE MUST PROPERLY SECURE;61R09-ILLEGAL ADDITION AND MAIN DISCONNECT ... | $1,030 | $0 | Dec 19, 2014 |
| Oct 25, 2013 | 35010502R | ACTIVE | CLASS - 2 | SIDEWALK SHED DOES MEET CODE SPECIFICATIONS. UPON INSPECTION UNDERSIDEOF SIDEWALK SHED NOT PROPER LIT. RMDY:COMPLY WI... | $500 | $0 | Mar 14, 2014 |
| May 8, 2012 | 38221271H | RESOLVE | CLASS - 2 | 37D06,37T07,52K10,42Q07,58F10,44H08,08V10,26D06,08V10: 52;RUSTED WITH ROUGE. 42;PROVIDE GUARD FOR SELECTOR CHAIN BY C... | $500 | $0 | Jun 29, 2012 |
| Apr 2, 2012 | 32072050J | ACTIVE | CLASS - 2 | B254,15,48A,50A,B. 50A- WATER LEAK FROM BOILER CHAMBER/TUBES. 50B- MISSING BOLTS @ CHAMBER DOOR. REPAIR/REPLACE ALL D... | $2,500 | $0 | Jun 29, 2012 |
| Jan 18, 2012 | 38220415N | RESOLVE | CLASS - 2 | 03M11,08V01,14M07,16L10,20M07,21Q03,35Q03,37X10,37Q03,39O02,56Y13,60Q03,67M07,70O02: 03M11-REPLACE HAND RAILS IN CAR,... | $0 | $0 | Mar 16, 2012 |
| Dec 14, 2005 | 38164255J | RESOLVE | Non-Hazardous | 43H8/58H11. | $350 | $0 | Aug 4, 2006 |
| Dec 15, 2004 | 38156638R | RESOLVE | Non-Hazardous | 3D6/5K10/16H11/21D6/4D6/55F10/51K11/58H11/41G11/57H10/40M7/39Q3/83O2 3- RESECURE STRIKE POST AND RETURN POST. 5-REPAI... | $180 | $0 | Jan 28, 2005 |
| May 17, 2004 | 38147014Y | RESOLVE | Non-Hazardous | 83O02,86U05,21D06,57L10,55O02,66O02,03D06,05L10,51H10.21-5TH FLOOR.57-ELIMINATE EXESSIVE BACK-LASH.03D06-STRIKE POST.... | $180 | $0 | Aug 27, 2004 |
| Sep 25, 2003 | 34408794L | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ELEVATOR LANDING SIGN THAT SHALL READ "IN CASE OF FIRE USE STAIRS UNLESS OTHERWISE INSTRUCTED"ON F... | $400 | $0 | Jan 16, 2004 |
| Oct 10, 2001 | 38116264P | RESOLVE | Non-Hazardous | 50F11-57O2-73B7-25Q7-33P17-33#12- CAR JUMP UP AND DOWN WIND STOP IT FL LEVEL. PROVIDE THE RIGHT CITY ID ON DEVICE. RE... | $0 | $0 | Nov 23, 2001 |
| Mar 13, 2001 | 34270592Y | ACTIVE | Hazardous | FAILURE TO MAINTAIN PLUMBING AND OR APPURTENANCES HAZARDOUS.FOUND IN CRAWL SPACE FOUND BUILDING HOUSE DRAIN WITH SEWA... | $800 | $0 | May 11, 2001 |
| Apr 3, 2000 | 38094986M | RESOLVE | Non-Hazardous | 5702/5F11/54I11/33DD/17I10/35H11/50A7 - 33 PATCH I BEAM IN OVERHEAD LOOSE BRICK WORK 54 REPAIR DAMAGE BRAKE BOX 35 RE... | $0 | $0 | May 26, 2000 |
| Sep 10, 1997 | 34155172Y | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN TEH FRONT EXTERIOR WALL: BRICKS ABOVE AND ALONG SIDE THE APARTMENT WINDOWS 5G & GE ARE BULGING. A... | $0 | $0 | Oct 24, 1997 |
| Aug 1, 1997 | 34155090K | ACTIVE | Non-Hazardous | FAILURE TO MAINTAIN THE REAR BUILDING WALL CHIMNEY: THERE ARE Z VERTICAL CRACKS, FROM GRADE THROUGH THE ROOF, AT OPPO... | $175 | $0 | Jan 9, 1998 |
| Jul 17, 1995 | 38050462R | RESOLVE | Non-Hazardous | 74#.74-FAILURE TO FILE WITH THIS DEPT FOR DISMANTLE AND /OR REMOVAL OF ELEVATOR AT LOCATION ABOVE | $0 | $0 | Sep 22, 1995 |
| Jul 9, 1991 | 38014052X | RESOLVE | Non-Hazardous | 14M,17M,02L,57O | $75 | $0 | Oct 25, 1991 |