ECB violations

1080 Anderson Avenue, Bronx • Block 02505 • Lot 0006

40 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Nov 29, 2025 35717687L RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTED:AT THE TIME OF INSPECTION OBSERVED AT EXP #3(EA... $2,500 $0 Mar 13, 2026
Oct 15, 2025 35717790J RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING FACADE WALLS AND APPURTENANCES.NOTE:AT THE TIME OF INSPECTION I OBSERVED AT EX#4 SOUTH E... $1,250 $1,250 Jul 24, 2026
Apr 29, 2024 39528081J RESOLVE CLASS - 2 AT A 6 STORY OCCUPIED BUILDING. I NOTICED SIDEWALK SHED HAS MISSING A INFORMATION PANEL ON PARAPET. THIS CREATES A UN... $1,280 $0 Apr 1, 2025
Dec 2, 2022 37024281M RESOLVE CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE9A REPORT OF CRITICAL EXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTEN... $625 $0 Mar 3, 2023
Nov 2, 2022 35664561J ACTIVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG FACADE&APPURTENANCES.OBSERVED DAMAGED/OPEN MORTAR JOINTS@PARAPET LEVEL&VARIOUS LOCA... $1,250 $0 Feb 3, 2023
Sep 9, 2022 39069726H RESOLVE CLASS - 1 CLASS 1 VIOLATION ISSUED RECURRING, DLM IMPROPER INSTALLED ON DEVICE. NO FIREMAN SERVICE PRESENTED IN CONTROLLER INST... $3,125 $0 Dec 2, 2022
Aug 4, 2022 39067393J RESOLVE CLASS - 1 CLASS 1 DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN'S SERVICE PRESENT IN THE CONTROLLER. INSTALL FIREMAN'S SE... $1,563 $0 May 12, 2023
Jun 8, 2022 39063720J RESOLVE CLASS - 1 CLASS 1 RECURRING VIOLATION ISSUED DLM IMPROPERLY INSTALLED ON THIS DEVOICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER... $1,250 $0 Apr 24, 2023
May 24, 2022 39062799R RESOLVE CLASS - 1 CLASS 1 VIOLATION RECURRING ISSUED , DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLE... $1,563 $0 Apr 18, 2023
Jan 19, 2022 39054579P RESOLVE CLASS - 1 CLASS 1 ITEM, DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER. INSTALL FIREMAN SERV... $3,125 $0 Dec 7, 2022
Sep 9, 2021 39047347K RESOLVE CLASS - 1 CLASS 1 VIOLATION ISSUED, NO FIRE SERVICE INSTALLED IN THIS CONTROLLER AS PER CODE DLM AS TO WORK ON PHASE 1&2 IN THE... $3,125 -$3,125 Dec 17, 2021
Jul 27, 2021 39045016R RESOLVE CLASS - 1 THE COMMISSIONER ORDERS THAT YOU TIMELY CORRECT THESE CONDITIONS AND FILE A CERTIFICATE OF SUCH CORRECTION. SEE 1RCNY... $0 $0 Jan 11, 2023
Apr 26, 2021 39040007M RESOLVE CLASS - 2 RESTORE SERVICE TO SECOND FLOOR LANDING, DOOR BOLTED SHUT AND ELEVATOR DOESN'T STOP THERE. PROVIDE FIRE SERVICE AS PE... $3,250 $0 Dec 3, 2021
Feb 16, 2021 39036240R RESOLVE CLASS - 2 PROVIDE FIRE SERVICE ON THIS DEVICE AS PER 2.27.3.3.6 OF APPENDIX K OF THE 2014 NYCBC. REMEDY: OBTAIN PERMIT, INSTALL... $1,562 -$1,562 May 21, 2021
Jan 7, 2021 39034482K RESOLVE CLASS - 2 CLASS 2 VIOLATION ISSUED. ITEM, AS TO PERMIT ISSUED AND WORK COMPLETED, AS PER SEC 2.27.3.3.6 OF THE NYCBC, FIREMAN S... $625 $0 Mar 5, 2021
Oct 27, 2020 39031123P RESOLVE CLASS - 1 DOOR RESTRICTOR ALTERED (CEASE USE). TOP OF CAR PLANK SWITCH NOT TIED TO GOVERNOR ROPE. $1,250 $0 Dec 18, 2020
Sep 11, 2020 39028524Z RESOLVE CLASS - 2 ADJUST FLOOR HEIGHTS. DOOR FOR OVERHEAD DOESN'T CLOSE. $1,562 -$1,562 Dec 4, 2020
Feb 3, 2020 38272013P RESOLVE CLASS - 1 42M07, 08V01, 56Y13: 42-M-07 NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF... $1,250 $0 Sep 25, 2020
Oct 5, 2019 38271858M RESOLVE CLASS - 2 21-B-10,52-M-07,58-H-10,05-J-10=(1)21-B-# 5 FLOOR HOISTWAY DOOR BRAKE CONTACT WHEN PULL ON (2) 52-M-# PROVIDE TAG (3)... $655 $0 Nov 29, 2019
Apr 24, 2019 38269417Y RESOLVE CLASS - 1 CEASE USE:05.M.07,(C/U)08.V.01,02.X.10,23.I.10,25.M.07,56.Y.13,68.B.07,59.BB.07,42.M.07,42.B.09,60.Q.03,61.B.09,(R/C)... $3,125 $0 Nov 19, 2019
Oct 14, 2018 38264437Z RESOLVE CLASS - 2 32H1,58H10,100D6/9; 70O2. 32-GUIDESHOES WORN ADJUST; 58-BEARINGS WORN REPAIR; 100-MISCELLANEOUS UNSECURED WIRE IN SHA... $625 $0 May 3, 2019
Nov 14, 2016 38251254N RESOLVE CLASS - 2 2M7,32H10,52B14,70OQ,71X10. 2-OUTSIDE COMMUNIATION CAR PHONE MISSING PROVIDE; 32-GUIDESHOES WORN REPAIR; 52-HOIST ROP... $0 $0 Jan 6, 2017
Sep 29, 2016 38246212Z RESOLVE CLASS - 1 CEASE USE. 5D10. CAB DOOR HAS A GAP WHEN FULLY CLOSE (REPAIR). $1,000 $0 Feb 10, 2017
Feb 27, 2016 38240598N RESOLVE CLASS - 2 02M07,21L10,70O02,71M07,70M07,37X07,42U11,68B07. 02-COMMUNICATION IN CAR MISSING PROVIDE; 21-INTERLOCK IN BSMT NO ACC... $0 $0 Apr 15, 2016
Aug 16, 2014 38232469R RESOLVE CLASS - 1 C/U 21D06,61R09,08J01. 21D06-6TH FLR INTERLOCK LOOSE MUST PROPERLY SECURE;61R09-ILLEGAL ADDITION AND MAIN DISCONNECT ... $1,030 $0 Dec 19, 2014
Oct 25, 2013 35010502R ACTIVE CLASS - 2 SIDEWALK SHED DOES MEET CODE SPECIFICATIONS. UPON INSPECTION UNDERSIDEOF SIDEWALK SHED NOT PROPER LIT. RMDY:COMPLY WI... $500 $0 Mar 14, 2014
May 8, 2012 38221271H RESOLVE CLASS - 2 37D06,37T07,52K10,42Q07,58F10,44H08,08V10,26D06,08V10: 52;RUSTED WITH ROUGE. 42;PROVIDE GUARD FOR SELECTOR CHAIN BY C... $500 $0 Jun 29, 2012
Apr 2, 2012 32072050J ACTIVE CLASS - 2 B254,15,48A,50A,B. 50A- WATER LEAK FROM BOILER CHAMBER/TUBES. 50B- MISSING BOLTS @ CHAMBER DOOR. REPAIR/REPLACE ALL D... $2,500 $0 Jun 29, 2012
Jan 18, 2012 38220415N RESOLVE CLASS - 2 03M11,08V01,14M07,16L10,20M07,21Q03,35Q03,37X10,37Q03,39O02,56Y13,60Q03,67M07,70O02: 03M11-REPLACE HAND RAILS IN CAR,... $0 $0 Mar 16, 2012
Dec 14, 2005 38164255J RESOLVE Non-Hazardous 43H8/58H11. $350 $0 Aug 4, 2006
Dec 15, 2004 38156638R RESOLVE Non-Hazardous 3D6/5K10/16H11/21D6/4D6/55F10/51K11/58H11/41G11/57H10/40M7/39Q3/83O2 3- RESECURE STRIKE POST AND RETURN POST. 5-REPAI... $180 $0 Jan 28, 2005
May 17, 2004 38147014Y RESOLVE Non-Hazardous 83O02,86U05,21D06,57L10,55O02,66O02,03D06,05L10,51H10.21-5TH FLOOR.57-ELIMINATE EXESSIVE BACK-LASH.03D06-STRIKE POST.... $180 $0 Aug 27, 2004
Sep 25, 2003 34408794L RESOLVE Non-Hazardous FAILURE TO PROVIDE ELEVATOR LANDING SIGN THAT SHALL READ "IN CASE OF FIRE USE STAIRS UNLESS OTHERWISE INSTRUCTED"ON F... $400 $0 Jan 16, 2004
Oct 10, 2001 38116264P RESOLVE Non-Hazardous 50F11-57O2-73B7-25Q7-33P17-33#12- CAR JUMP UP AND DOWN WIND STOP IT FL LEVEL. PROVIDE THE RIGHT CITY ID ON DEVICE. RE... $0 $0 Nov 23, 2001
Mar 13, 2001 34270592Y ACTIVE Hazardous FAILURE TO MAINTAIN PLUMBING AND OR APPURTENANCES HAZARDOUS.FOUND IN CRAWL SPACE FOUND BUILDING HOUSE DRAIN WITH SEWA... $800 $0 May 11, 2001
Apr 3, 2000 38094986M RESOLVE Non-Hazardous 5702/5F11/54I11/33DD/17I10/35H11/50A7 - 33 PATCH I BEAM IN OVERHEAD LOOSE BRICK WORK 54 REPAIR DAMAGE BRAKE BOX 35 RE... $0 $0 May 26, 2000
Sep 10, 1997 34155172Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN TEH FRONT EXTERIOR WALL: BRICKS ABOVE AND ALONG SIDE THE APARTMENT WINDOWS 5G & GE ARE BULGING. A... $0 $0 Oct 24, 1997
Aug 1, 1997 34155090K ACTIVE Non-Hazardous FAILURE TO MAINTAIN THE REAR BUILDING WALL CHIMNEY: THERE ARE Z VERTICAL CRACKS, FROM GRADE THROUGH THE ROOF, AT OPPO... $175 $0 Jan 9, 1998
Jul 17, 1995 38050462R RESOLVE Non-Hazardous 74#.74-FAILURE TO FILE WITH THIS DEPT FOR DISMANTLE AND /OR REMOVAL OF ELEVATOR AT LOCATION ABOVE $0 $0 Sep 22, 1995
Jul 9, 1991 38014052X RESOLVE Non-Hazardous 14M,17M,02L,57O $75 $0 Oct 25, 1991