ECB violations
West 167 Street, Bronx • Block 02505 • Lot 0050
130 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 18, 2010 | 34837299J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING WEST ELEVATION OBSERVE VERTICAL AND STEP CRACKS AND DISPLACED IN LINTEL FACADE;... | $250 | $0 | Jul 16, 2010 |
| Apr 16, 2010 | 38209538X | RESOLVE | CLASS - 2 | 20I11, 16B01, 14M7, 26T15, 8V1, 77K10, 68M7, 69M7, 40O2 | $250 | $0 | Oct 22, 2010 |
| Mar 18, 2010 | 34812568H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR OF BUILDING DEFECT ON THE NORTHSIDE.EXPOSURE 2,OF WALL @ ENTRY COURTYARD;THERE ARE SEVER... | $1,000 | $0 | May 28, 2010 |
| Feb 11, 2010 | 34830437R | RESOLVE | CLASS - 3 | FAIL TO MAINTAIN BLDG WALLS OR APPURT.NOTE:BRICK ENTRANCE EXTERIOR VESTIBULE HAS SETTLED W/SEPARATION CRACKS @ LEFT &... | $200 | $0 | Apr 2, 2010 |
| Feb 11, 2010 | 34830438Z | RESOLVE | CLASS - 2 | FAILURE TO FILE COFC VIO#34808251H,34808252J.REM:FILE COFC | $800 | $0 | Aug 20, 2010 |
| Oct 23, 2009 | 36009989X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH RD TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIO... | $4,000 | $0 | Jan 22, 2010 |
| Oct 23, 2009 | 38206923Z | RESOLVE | CLASS - 2 | 08V10.56O2.68M7.08V10 ADJUST FL STOPS WERE NEEDED 56Y13 SEAL OIL LEAK HOIST MACHINE 56O2 CLEAN OIL HOIST MACHINE BEDP... | $2,500 | $0 | Dec 18, 2009 |
| Sep 16, 2009 | 34808252J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG EXTERIOR OBSERVED:ENTRY FOYER TO LDG STRUCTURE APPROX. 8'W X 6'D X 20'H STRUCTURE SINKING IN... | $5,000 | $0 | Nov 6, 2009 |
| Sep 16, 2009 | 34808251H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG INTERIOR OBSERVED:AT CELLAR LEVEL INADEQUATE SUPPORT FOR CEILING USING 2 X 4 AND 4 X 4 WOOD ... | $5,000 | $0 | Nov 6, 2009 |
| Sep 16, 2009 | 34808250X | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/AN ORDER FROM THE COMMISSIONER TO FILE A COFC W/ DOB FOR NOV # 34735547M ISSUED 4/2/09 FOR FAILUR... | $4,000 | $0 | Nov 6, 2009 |
| Sep 1, 2009 | 38205260M | RESOLVE | CLASS - 1 | CU 78L10.14M7.56O2. CU 78L10 GOVERNOR TENSION SHEAVE IS WORN AND RUSTED THERE IS SLACK IN GOVERNOR ROPE BEFORE RETURN... | $5,000 | $0 | Oct 30, 2009 |
| Apr 2, 2009 | 34735547M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER. DEFECT NOTED: INADEQUATE SUPPORT 2X4'S & 4X4'S WOOD STUDS BEIN... | $1,000 | $0 | Jun 11, 2010 |
| Apr 2, 2009 | 34735548Y | RESOLVE | CLASS - 3 | WORK W/O A PERMIT WORK NOTED: FLR TO CEILING PARTITION ERECTED AT NORTH/EAST SECTION OF THE BUILDING TO CREATE ADDITI... | $0 | $0 | May 29, 2009 |
| Feb 6, 2009 | 38201041Y | RESOLVE | CLASS - 2 | 32H10,21M07,16M07 32H-REPAIR OR REPLACE CAR CHOES WORN 21M-PROVIDE MISSING 2ND FLOOR INTERLOCK COVER 16M-PROVIDE MISS... | $500 | $0 | Apr 3, 2009 |
| Feb 6, 2009 | 38201040M | RESOLVE | CLASS - 2 | X52B14,32H10,42XXXX,16M07. 52B-SHORTEN HOIST ROPES 4" BEFORE HITTING BUFFER SPRING 32H-REPAIR OR REPLACE WORN CAR SHO... | $250 | $0 | Apr 3, 2009 |
| Feb 6, 2009 | 38201042X | RESOLVE | CLASS - 1 | 53I11,78K10,32H10,16M07,100I10,05K11 53-REPLACE DAMAGED GOVERNOR ROPES KINKED 78-REPAIR & LUB GOVERNOR TERVISION SHEA... | $1,000 | $0 | Apr 3, 2009 |
| Jan 23, 2009 | 36007971Z | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... | $4,000 | $0 | Sep 18, 2009 |
| Dec 15, 2008 | 38199684H | RESOLVE | CLASS - 2 | 08V01.05J01.16B10.24M07.08V01.ADJUST FL STOPS OFF LEVEL 05J01 ADJUST CAB DOOR FROM RUBBING WHEN CLOSING 16B10 REPAIR ... | $500 | $0 | Feb 13, 2009 |
| Dec 15, 2008 | 38199683X | RESOLVE | CLASS - 2 | 01L10.16M07.16D06.05K11.12Q03.42A09.35I10.59B07.100B10.01L10 REPAIR STOP SW 16M07 PROVIDE MISSING HATCH DOOR GLASS 16... | $500 | $0 | Feb 13, 2009 |
| Dec 15, 2008 | 38199682Y | RESOLVE | CLASS - 1 | 43I11.32H10.21M07.24M07.70O02.61D06.CUI 42I11 REPLAC E DAMAGED SELECTOR TAPE NON C.U 32H10 REPAIR OR REPLACE WORN CAR... | $1,000 | $0 | Feb 13, 2009 |
| Dec 9, 2008 | 32065002J | RESOLVE | CLASS - 1 | B154,7A,34B,48A,51,50,50A,50B,50C. 50 BUCKETS OF OIL IN BOILER ROOM. 50A GASKET AROUND FRONT DOOR TO BE REPLACED. 50B... | $1,000 | $0 | Feb 13, 2009 |
| Aug 12, 2008 | 38189721Z | RESOLVE | CLASS - 2 | 16X10.21Q03.37T07.56Y13.60Q03. 16X10 REPAIR 4TH FL HOISTWAY DOOR & BETWEEN 4 FL TO OPERATION 21Q03 INSTALL COVER FOR ... | $500 | $0 | Oct 3, 2008 |
| Aug 4, 2008 | 32060139H | RESOLVE | CLASS - 3 | B354 16.32A.34B.50.50A.50 GUARD MISSING ON FAN BELT & PULLEY ON TRANSFER PUMP 50A DISCHARGE PIPE MISSING ON 530C VALVE | $500 | $0 | Oct 3, 2008 |
| Aug 4, 2008 | 38189964N | RESOLVE | CLASS - 2 | 100L10,16L10,08V01,32L10,05L10,100L10,24L10.100L-4FL HOISTWAY DOOR NEEDS TO BE REPAIRED (HAS TO OPEN)16L-HOISTWAY DOO... | $0 | $0 | Oct 3, 2008 |
| Aug 4, 2008 | 38189966R | RESOLVE | CLASS - 2 | 20I10.32L10.8V1.16L10.97L10.12Q10.100B10.28L10.16L10.20M10. 20I VISION PANEL DAMAGES 1 & 3 FL 32L CAR GUIDE SHOES NEE... | $0 | $0 | Oct 3, 2008 |
| Aug 4, 2008 | 38189965P | RESOLVE | CLASS - 2 | 32L10.8V1.16L10.28L10.20I10.32L CAR GUIDE SHOES NEED REPAIR 8V LEVELING IS OFF 16L HOISTWAY DOOR CHECK NEED REPAIR 28... | $0 | $0 | Oct 3, 2008 |
| Jul 1, 2008 | 38188902N | RESOLVE | CLASS - 2 | 83X10 83/X10 1 RCNY ONLY ELEVATOR IN BLDG OUT OF SERVICE, RESTORE TO SERVICE. | $500 | $0 | Sep 19, 2008 |
| Jul 1, 2008 | 38188903P | RESOLVE | CLASS - 3 | 16L10,32L10,12Q10,97L10,28L10,8V1,20I10,16L10 16L HOISTWAY DOOR CHECKS32L CAR GUIDE SHOES DEFECTIVE 97L NOISE IN HOIS... | $200 | $0 | Sep 19, 2008 |
| Jul 1, 2008 | 38188904R | RESOLVE | CLASS - 3 | 16L10,8V1,83L10,16T7,84L10,5L10,39P7 16L HOISTWAY DOOR CHECKS NEED REPAIR 8V LEVELING IS OFF 83L CAR BOUNCES WHEN (TR... | $500 | $0 | Aug 29, 2008 |
| Jun 23, 2008 | 38185485H | RESOLVE | Non-Hazardous | 83X10 83X10 1RCNY 11-02 ONLY ELEVATOR IN BLDG OUT OF SERVICE RESTORE TO SERVICE | $800 | $0 | Aug 11, 2009 |
| Jun 16, 2008 | 38184949M | RESOLVE | Non-Hazardous | 16L10.8L10.16T7.31H10.39P7. 16L HOISTWAY DOOR CHECKS 5L CAR DOOR NEEDSADJUSTMENT 31H CAR GUIDE SHOES WORNNEED TO BE R... | $0 | $0 | Aug 15, 2008 |
| Jun 16, 2008 | 38185875N | RESOLVE | Hazardous | 83X10. 83X10 1RCNY 11-02 ONLY ELEVATOR IN BLDG OUT OF SERVICE RESTORE TO SERVICE. | $800 | $0 | Aug 11, 2009 |
| Jun 16, 2008 | 38184947Z | RESOLVE | Non-Hazardous | 83X10. 83X10 1RCNY 11-02 ONLY ELEVATOR IN BLDG OUT OF SERVICE RESTORE TO SERVICE. | $800 | $0 | Aug 11, 2009 |
| Apr 28, 2008 | 38184359M | RESOLVE | Hazardous | 08V01.31H10.51B14.60Z11.CU ITEM 08V01 FL STOPS OFF LEVEL 2 TO 3 INCH IN UP & 5 TO 6 IN. IN DOWN NON CEASE USE 31H10 R... | $2,500 | $0 | Jun 27, 2008 |
| Apr 28, 2008 | 38184360J | RESOLVE | Non-Hazardous | 14B11.12Q03.58B07.34D06.83B10. 14B11 MIRROR DAMAGED CANT SEE TO ELEVATOR DEAD SPOT 58B07 PROVIDE CARTER PIN ON BRAKE ... | $2,500 | $0 | Jun 27, 2008 |
| Feb 6, 2008 | 38181605P | RESOLVE | Non-Hazardous | 21Q03,34Q03,36D06,36T07,55Y13,55Y10,56Y10,59Q03,39Y02.21Q03-INSTALL COVER FOR 2FL HOISTWAY DOOR INTERLOCK.34Q03-INSTA... | $0 | $0 | Apr 4, 2008 |
| Feb 6, 2008 | 38181604N | RESOLVE | Non-Hazardous | 14M11,36O02,36D06,36W07,36Q03,38X10,51M07,34D06,38Q03,59Q03.36O20-CLEAN OVERHEAD SHEAVE ROOM.36D06-PROPERLY SECURE OV... | $0 | $0 | Apr 4, 2008 |
| May 3, 2007 | 34570019X | RESOLVE | Hazardous | USE OF RIGGING EQUIPMENT W/O A LICENSE (2PT SCAFFOLD). REMEDY: REFER TO SWO # 17126 | $1,250 | $0 | Sep 21, 2007 |
| May 3, 2007 | 34570017M | RESOLVE | Hazardous | LICENSED RIGGER FAILED TO SUPERVISE RIGGER WORK NO QUALIFIED FOREMAN REMEDY:REFER TO SWO # 17126. | $250 | $0 | Aug 17, 2007 |
| May 3, 2007 | 34570018Y | RESOLVE | Hazardous | LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQUIREMENT (NO CERT OF FITNESS). REMEDY: REFER TO SWO #... | $500 | $0 | Sep 21, 2007 |
| May 3, 2007 | 34570020N | RESOLVE | Hazardous | OPERATION OF HOISTING EQUIPMENT( 2 PT SCAFFOLD) IN AN UNSAFE MANNER. REMEDY:REFER TO SWO # 17126 | $4,000 | $0 | Nov 9, 2007 |
| Apr 25, 2007 | 34575035Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR.MASONRY COLUMNS ARE CRACKED & SPALLING AT SE CORNER OF THE BLDG.REMEDY:REPAIR DEFECT. | $2,000 | $0 | Jul 20, 2007 |
| Oct 16, 2006 | 38162232H | RESOLVE | Non-Hazardous | 85U05/36O02/336D06/02X10/39O02/40D06/55O02/55Y10/05E10/20I12/38O02/28Q03/16L10/21Q03/15I10/60Q03.20I12-CAB DOOR GLASS... | $880 | $0 | Dec 1, 2006 |
| Oct 16, 2006 | 38162231X | RESOLVE | Non-Hazardous | 85H05/36D06/36O02/20I11/05E10/05K10/71K10/12Q03/38O02/28Q03/31H10/08V10/39O02/40D06/55O02/55Y10/15I11/84M07/03D06/58M... | $0 | $0 | Jan 9, 2007 |
| Oct 16, 2006 | 38162244P | RESOLVE | Non-Hazardous | 85U05/36D06/36O02/20I11/05E10/05K10/71K10/12Q03/38O02/28Q03/31H10/08V10/39O02/40D06/55O02/55Y10/15I11/84M07/03D06/58M... | $2,500 | $0 | Jan 26, 2007 |
| Oct 16, 2006 | 38162230Y | RESOLVE | Non-Hazardous | 85U05/36D06/39D06/39O02/59X10/03Q03/03M07/28Q03/02BB10/71K10/16L10/84M07/55O02/55Y10/58Y02/15I10/38O02.36-NO LOCK ON ... | $350 | $0 | Dec 1, 2006 |
| Sep 8, 2006 | 38161377Y | RESOLVE | Non-Hazardous | CEASE USE, HAZARDOUS.3J1/5J1/16T7/20I10/25#6/28Q3/34Q3/36W6/3602/3802/3902/16I11/85BB5/71M7/60D6/55Y13/40W6.3 WALL 5 ... | $500 | $0 | Oct 27, 2006 |
| Sep 8, 2006 | 38161378X | RESOLVE | Non-Hazardous | CEASE USE,HAZARDOUS.39Z10/41Q3/40W6/55Y13/8V1/16T7/52L11/5I11/10M7/71M11/34Q3/25#6/28Q3/12Q3/85BB5/36R11/36#6.41 CHAN... | $500 | $0 | Oct 27, 2006 |
| Sep 8, 2006 | 38161379H | RESOLVE | Non-Hazardous | 25BB5/38R6/25#6/38I10/28Q3/34D6/40W6/60R9/55X13/3902.38 WIRING 25 AS PER CODE 38 WONK LIGHT 60 WIRES NOT FOR ELEV | $350 | $0 | Oct 27, 2006 |
| Apr 12, 2006 | 34515647P | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR RETAINING WALL. REAR RETAINING WALL HAS VARIOUS CRACKS THRU-OUT. MASONRY COLUMNS ARE CRA... | $800 | $0 | Feb 9, 2007 |