ECB violations
1245 Edward L Grant Highway, Bronx • Block 02506 • Lot 0054
27 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 26, 2024 | 39120025X | RESOLVE | CLASS - 2 | PROVIDE DESIGNATED LOBBY BRAILLE TAGS. BRAKE MAINTENANCE TAG MUST HAVE FULL DATE. | $0 | $0 | Oct 4, 2024 |
| Jul 26, 2024 | 39120024Y | RESOLVE | CLASS - 2 | PROVIDE DESIGNATED LOBBY BRAILLE TAGS. BRAKE MAINTENANCE TAG MUST HAVE FULL DATE. | $0 | $0 | Oct 4, 2024 |
| Aug 19, 2023 | 39520778N | RESOLVE | CLASS - 1 | AT THE TIME OF MY INSPECTION OF A 12 STORY NB I OBSERVED WORKERS PERFORMING HOUSEKEEPING AT EXPOSURE 1. SIDEWALK FULL... | $2,400 | $0 | Mar 15, 2024 |
| Apr 17, 2023 | 35653996P | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DEPARTMENT OF AN ACCIDENT INCIDENT THAT RESULTEDIN A FATALITY OR AN INJURY.NOTE:A PEDESTRIAN ST... | $12,500 | $0 | Oct 1, 2024 |
| Mar 6, 2023 | 39513831H | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE AND MAINTAIN SAFETY MEASURES. AT TIME OF INSPECTION I OBSERVED ON NUMEROUS FLOORS ELECTRICAL PAN... | $6,250 | $0 | Nov 19, 2024 |
| Mar 6, 2023 | 39513828R | RESOLVE | CLASS - 1 | STORAGE& SAFEGUARDING OF MATERIAL AND EQUIPMENT. IN RESPONSE TO INCIDENT I OBSERVED STREET AREA WHERE FORK LIFT WAS P... | $6,250 | $0 | Nov 19, 2024 |
| Mar 6, 2023 | 39513829Z | RESOLVE | CLASS - 1 | MANUFACTURE SPECIFICATIONS. IN RESPONSE TO INCIDENT WHERE MOTORCYCLIST HIT FORKLIFT IN STREET AREA UPON REQUEST TO SE... | $6,250 | $0 | Nov 19, 2024 |
| Mar 6, 2023 | 39513830X | RESOLVE | CLASS - 1 | USE AND TAMPERING PROHIBITED. IN RESPONSE TO INCIDENT WHERE MOTORCYCLIST HIT PARKED FORKLIFT IN STREET I OBSERVED FOR... | $6,250 | $0 | Nov 19, 2024 |
| Jan 10, 2023 | 39511464X | RESOLVE | CLASS - 2 | 12 STORY NB, I OBSERVED SIDEWALK SHED(SWS) AT EXP1, NEAR EXP2, HORIZONTAL BRACE AT 6F 10INCHES, LESS THAN THE MINIMUM... | $2,400 | $0 | Feb 23, 2024 |
| Jan 10, 2023 | 39511465H | RESOLVE | CLASS - 2 | 12 STORY NB, I OBSERVED LARGE ACCUMULATION OF COMBUSTIBLE DEBRIS MADE OUT OF PAPER, PLASTIC BAGS, WOOD, ON THE GROUND... | $0 | $0 | Mar 17, 2023 |
| Dec 2, 2022 | 39509863K | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF AN ACTIVE SITE, OBSERVED UNSAFE ONE LEVEL SCAFFOLD ON THE ROOF. SCAFFOLD WAS MISSING GUARD R... | $0 | $0 | Feb 17, 2023 |
| Aug 23, 2022 | 39505407Z | RESOLVE | CLASS - 1 | OBSERVED SIDEWALK SHED ERECTED AT NEW 12 STY BUILDING WITH NO LIGHTS ON AND FIXTURES PRESENT CREATING A HAZARDOUS CON... | $625 | $0 | Jan 27, 2023 |
| Aug 23, 2022 | 39505408K | RESOLVE | CLASS - 1 | AT TIME OF COMPLAINT INSPECTION AT NEW 12 STORY BUILDING APPROXIMATELY 6320 SQUARE FEET. OBSERVED JOBSITE CLOSED WITH... | $625 | $0 | Jan 27, 2023 |
| Aug 22, 2022 | 39505377R | RESOLVE | CLASS - 1 | OBSERVED HORIZONTAL NETTING ATTACHED / TIED TOO D-RINGS UPON REQUEST TO SEE DESIGN DRAWINGS FOR HORIZONTAL NETTING SH... | $625 | $0 | Jan 27, 2023 |
| Aug 22, 2022 | 39505363X | RESOLVE | CLASS - 1 | OBSERVED LARGE AMOUNTS OF CONSTRUCTION DEBRIS ( WOOD, CONCRETE AND METAL) PILED HIGH AND SCATTERED THROUGHOUT JOBSITE... | $625 | $0 | Jan 27, 2023 |
| Aug 22, 2022 | 39505364H | RESOLVE | CLASS - 1 | OBSERVED GUARDRAIL AT EXPO #2 ON 11 STORY AT LEADING EDGE NOT PROPERLY SECURED LOOSE AND WOBBLY CAUSING A POTENTIAL F... | $2,500 | $0 | Jan 27, 2023 |
| Aug 22, 2022 | 39505365J | RESOLVE | CLASS - 1 | OBSERVED MISSING ELECTRICAL COVER PANEL AT CIRCUIT BREAKER 1ST STORY CREATING A ELECTRICAL HAZARD TO WORKERS AND PERS... | $625 | $0 | Jan 27, 2023 |
| Aug 22, 2022 | 39505367N | RESOLVE | CLASS - 1 | OBSERVED CONSTRUCTION MATERIAL STORED CLOSE TO LEADING EDGE CREATING A HAZARDOUS CONDITION FROM MATERIAL FALLING OFF ... | $625 | $0 | Jan 27, 2023 |
| Aug 22, 2022 | 39505366L | RESOLVE | CLASS - 2 | OBSERVED VERTICAL NETTING INADEQUATELY MAINTAINED WITH LARGE GAPS THROUGHOUT JOBSITE ALLOWING MATERIAL AND DEBRIS TOO... | $0 | $0 | Oct 7, 2022 |
| Jul 13, 2022 | 39503478R | RESOLVE | CLASS - 2 | INADEQUATE EGRESS. THERE IS ONLY ONE MEAN OF EGRESS FROM 6TH TO 9TH FLOOR LEVEL. INSTALL ONE MORE LADDER. | $0 | $0 | Sep 2, 2022 |
| Jul 13, 2022 | 39503471Y | RESOLVE | CLASS - 1 | CONTRACTOR CONTINUED WORK WHILE ON NOTICE OF STOP WORK ORDER ISSUED ON 06/04/2022 WITH COMPLAINT # 2346958 FOR FAILUR... | $5,000 | $0 | Sep 2, 2022 |
| Jul 13, 2022 | 39503475L | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO PLANS. NEEDLE BEAMS DETAILS MISSING INFORMATION-NO MEASUREMENTS FOR OVERHANGING PART AT EXPO... | $0 | $0 | Sep 2, 2022 |
| Jun 4, 2022 | 35651616P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING AS PER SECTION REQUIREMENTS-2ND,3RD,4TH FLOORS.AT TIME OF INSPECTION AT A 1... | $0 | $0 | Sep 2, 2022 |
| Jun 4, 2022 | 35651615N | RESOLVE | CLASS - 1 | 3309.1 & 3309.13 PROTECTION REQUIRED OF ADJOINING EQUIPMENT AND SPACESAT EXP4 SIDE-PARKING LOT AND ELECTRICAL EQUIPME... | $0 | $0 | Sep 2, 2022 |
| Jan 3, 2022 | 35636714N | RESOLVE | CLASS - 2 | 3301.7 DOCUMENTS TO BE KEPT ONSITE.I OBSERVED ACTIVE WORKSITE AT FOUNDATION PILE DRIVING PHASE.RESPONDING TO A COMPLA... | $620 | $0 | Apr 1, 2022 |
| Jan 3, 2022 | 35636715P | RESOLVE | CLASS - 2 | 3301.1.2 IMPROPER STORAGE OF FLAMMABLE GAS.I OBSERVED ACETYLENE TANKS AND OXYGEN TANKS STORED TOGETHER IN THE SAME CA... | $620 | $0 | Apr 1, 2022 |
| Jan 3, 2022 | 35636713L | RESOLVE | CLASS - 1 | FAILURE TO HAVE SITE SAFETY COORDINATOR PRESENT AT SITE REQUIRED.I OBSERVED ACTIVE WORKSITE AT FOUNDATION PHASE WITH ... | $10,000 | $0 | Dec 9, 2022 |