ECB violations
80 West 163 Street, Bronx • Block 02511 • Lot 0068
76 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 11, 2021 | 35558095M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT TIME OF INSPECTION OBSERVED AT EXP #1 AT ROOF LEVEL AT... | $1,250 | $0 | Nov 19, 2021 |
| May 11, 2021 | 35530514N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39038010K ISSUED ON 03/21/21 AND TO FILE ... | $0 | $0 | Nov 19, 2021 |
| May 11, 2021 | 35530515P | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39038009N ISSUED ON 03/21/21 AND TO FILE ... | $0 | $0 | Nov 19, 2021 |
| Mar 21, 2021 | 39038009N | RESOLVE | CLASS - 1 | OBSERVED PARTITIONS CREATED IN 963 FOR THE ENTIRE B LINE CREATING ILLEGAL OCCUPANCY THROUGHOUT THE B LINE., OBTAIN PE... | $0 | $0 | Oct 29, 2021 |
| Mar 21, 2021 | 39038010K | RESOLVE | CLASS - 1 | OBSERVED PARTITIONS CREATED AT 963 FOR THE ENTIRE B LINE CREATING ILLEGAL OCCUPANCY THROUGHOUT THE B LINE., DISCONTIN... | $0 | $0 | Oct 29, 2021 |
| Mar 21, 2021 | 39038011M | RESOLVE | CLASS - 1 | OBSERVED THE PARAPET AT 957 WAS CRACKED, SEPARATING AND NOT MAINTAINED IN A CODE COMPLAINT MANNER., REPAIR AND/REPLACE | $0 | $0 | Jul 16, 2021 |
| Jan 29, 2021 | 39035670M | RESOLVE | CLASS - 2 | COLD WATER PIPING OVER BOILER CORRODED AND LEAKING-RETURN PIPING CORRODED-COLD WATER PIPING HUNG W/PROHIBITED MATERIA... | $0 | $0 | Mar 19, 2021 |
| Nov 9, 2020 | 35477453Z | RESOLVE | CLASS - 2 | RESIDENCE CONVRTED MAINTAINED OR OCCUPIED AS A DWELLING FOR MORE THAN LEGALLT APPROVED NUMBER OF FAMILIES AUTHROIZED ... | $1,250 | $0 | Jan 29, 2021 |
| Nov 9, 2020 | 35477454K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER USE OF PROHIBITED DOOR AND/OR HARDWARE PER B C1008.1.8:27-371(J... | $312 | $0 | Jan 29, 2021 |
| Aug 19, 2020 | 39027245L | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED HOUSEHOLD STUFF INCLUDING MOP, BUCKET AND PLANTING TUB STORED ON FIRE ESCAPE OUTSIDE O... | $625 | $0 | Oct 16, 2020 |
| Jul 1, 2020 | 35454091Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:AT EXP4 4TH FLOOR,EXP3 1ST FLOOR,AND EXP3 2 FLOOR THAT FIRE ESC... | $0 | $0 | Sep 4, 2020 |
| Dec 23, 2019 | 39014768H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION THE PARAPET WALL IS IN A STATE OF DISR... | $0 | $0 | Mar 3, 2021 |
| Jul 31, 2018 | 32097421K | RESOLVE | CLASS - 2 | 50A,50B,50C-AS PER CLASS 2(B254)28-301.1 FAILURE TO MAINTAIN. 50A)NO MANUAL RESET ON LOW WATER CUT-OFF FOR WEIL-MCLAI... | $312 | $0 | Sep 21, 2018 |
| Mar 6, 2015 | 35079284N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT ENTRANCE CART FIRE ESCAPE,RIGHT SIDE BALCONIES ARE OBSTR... | $1,000 | $0 | Jul 31, 2015 |
| Apr 7, 2014 | 35093313Y | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO DEPT RECORDS NOTED @ APT 14A EVIDENT SIGNS OF SRO CONDITION ROOMS WITH LOCKING DEVICE,REFRIGERA... | $0 | -$600 | May 30, 2014 |
| Mar 1, 2014 | 32073543M | RESOLVE | CLASS - 2 | B201,50. 50-WORK W/O A PERMIT- LOCHINVAR BOILER IS BEING INSTALLED W/OA PERMIT. OBTAIN PROPER PERMIT. | $800 | $0 | Apr 18, 2014 |
| Feb 19, 2014 | 35085159P | RESOLVE | CLASS - 3 | WORK W/O A PERMIT. AT 4TH STORY APT DESIGNATED 23A ERECTED FULL HEIGHTPARTITION APPRX 12 LINEAR FEET LONG. RMDY: OBTA... | $230 | $0 | Apr 18, 2014 |
| Jan 21, 2014 | 35078336L | RESOLVE | CLASS - 3 | WORK W/O A PERMIT. FLR TO CEILING PARTITION ERECTED INSIDE APT #30B TOCREATE ADDITIONAL SPACE/ROOM. REMEDY: OBTAIN PE... | $0 | $0 | Mar 21, 2014 |
| Sep 20, 2013 | 32073793P | RESOLVE | CLASS - 1 | B154,16,43,49,50A,B. 50A- CLOGGED CHIMNEY BASE. 50B- IMPROPER COMBUSTION, BOILER EMITTING BLACK FUMES W/SOOT ALL OVER... | $1,000 | $0 | Nov 15, 2013 |
| Dec 3, 2012 | 32072149J | RESOLVE | CLASS - 2 | B254,21A,50A,B,C,D,E,F,G,H,I. 50A- COVERS MISSING ON CONTROLS. 50B-OILLEAK AT BURNER. 50C- SUPPLY PUMP CANNOT RUN. CO... | $0 | $0 | Jan 18, 2013 |
| Sep 25, 2012 | 34995598N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.DEFECT NOTED:AT BASEMENT LEVEL SIDE ENTRANCE TO APTS C&D DOOR STRIC... | $0 | $0 | Nov 16, 2012 |
| Nov 2, 2011 | 32071416K | RESOLVE | CLASS - 2 | 16 34AB 50A-DEFECTIVE DRAFT REGULATOR | $500 | $0 | Mar 30, 2012 |
| Jul 11, 2011 | 34912133R | RESOLVE | CLASS - 3 | WORK W/O A PERMIT NOTED:@ 3RD STORY,APT 18A,SOUTH EAST SECTION OF BLDG,ERECTED SHEETROCK INTERIOR PARTITION TO SUBDIV... | $200 | $0 | Sep 2, 2011 |
| Jul 21, 2007 | 32054422M | RESOLVE | Non-Hazardous | B4A-48A,50ABC.50A-PIPE HOT WATER RELIEF DISCHARGE DOWN NO THREADED END.50B-FLUE PIPE NOT PROPERLY SEALED TO CHIMNEY.5... | $180 | $0 | Nov 16, 2007 |
| Apr 3, 2007 | 32053286M | RESOLVE | Non-Hazardous | B4A,34A,50A,50B.50A-NEED SUPPORT ON FLUE PIPE.50B-HOLES ON THE WALLS. | $180 | $0 | Jun 1, 2007 |
| Sep 19, 2001 | 34289573Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL NOTED APPROX 30 TO 40 FEET OF COPING ON PARARET WALL MISSING GRACKED SPALL... | $2,500 | $0 | Nov 2, 2001 |