80 West 163 Street, Bronx • Block 02511 • Lot 0068

76 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
May 11, 2021 35558095M RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT TIME OF INSPECTION OBSERVED AT EXP #1 AT ROOF LEVEL AT... $1,250 $0 Nov 19, 2021
May 11, 2021 35530514N RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39038010K ISSUED ON 03/21/21 AND TO FILE ... $0 $0 Nov 19, 2021
May 11, 2021 35530515P RESOLVE CLASS - 1 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39038009N ISSUED ON 03/21/21 AND TO FILE ... $0 $0 Nov 19, 2021
Mar 21, 2021 39038009N RESOLVE CLASS - 1 OBSERVED PARTITIONS CREATED IN 963 FOR THE ENTIRE B LINE CREATING ILLEGAL OCCUPANCY THROUGHOUT THE B LINE., OBTAIN PE... $0 $0 Oct 29, 2021
Mar 21, 2021 39038010K RESOLVE CLASS - 1 OBSERVED PARTITIONS CREATED AT 963 FOR THE ENTIRE B LINE CREATING ILLEGAL OCCUPANCY THROUGHOUT THE B LINE., DISCONTIN... $0 $0 Oct 29, 2021
Mar 21, 2021 39038011M RESOLVE CLASS - 1 OBSERVED THE PARAPET AT 957 WAS CRACKED, SEPARATING AND NOT MAINTAINED IN A CODE COMPLAINT MANNER., REPAIR AND/REPLACE $0 $0 Jul 16, 2021
Jan 29, 2021 39035670M RESOLVE CLASS - 2 COLD WATER PIPING OVER BOILER CORRODED AND LEAKING-RETURN PIPING CORRODED-COLD WATER PIPING HUNG W/PROHIBITED MATERIA... $0 $0 Mar 19, 2021
Nov 9, 2020 35477453Z RESOLVE CLASS - 2 RESIDENCE CONVRTED MAINTAINED OR OCCUPIED AS A DWELLING FOR MORE THAN LEGALLT APPROVED NUMBER OF FAMILIES AUTHROIZED ... $1,250 $0 Jan 29, 2021
Nov 9, 2020 35477454K RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER USE OF PROHIBITED DOOR AND/OR HARDWARE PER B C1008.1.8:27-371(J... $312 $0 Jan 29, 2021
Aug 19, 2020 39027245L RESOLVE CLASS - 1 AT TIME OF INSPECTION OBSERVED HOUSEHOLD STUFF INCLUDING MOP, BUCKET AND PLANTING TUB STORED ON FIRE ESCAPE OUTSIDE O... $625 $0 Oct 16, 2020
Jul 1, 2020 35454091Z RESOLVE CLASS - 2 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:AT EXP4 4TH FLOOR,EXP3 1ST FLOOR,AND EXP3 2 FLOOR THAT FIRE ESC... $0 $0 Sep 4, 2020
Dec 23, 2019 39014768H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION THE PARAPET WALL IS IN A STATE OF DISR... $0 $0 Mar 3, 2021
Jul 31, 2018 32097421K RESOLVE CLASS - 2 50A,50B,50C-AS PER CLASS 2(B254)28-301.1 FAILURE TO MAINTAIN. 50A)NO MANUAL RESET ON LOW WATER CUT-OFF FOR WEIL-MCLAI... $312 $0 Sep 21, 2018
Mar 6, 2015 35079284N RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT ENTRANCE CART FIRE ESCAPE,RIGHT SIDE BALCONIES ARE OBSTR... $1,000 $0 Jul 31, 2015
Apr 7, 2014 35093313Y RESOLVE CLASS - 2 OCCUPANCY CONTRARY TO DEPT RECORDS NOTED @ APT 14A EVIDENT SIGNS OF SRO CONDITION ROOMS WITH LOCKING DEVICE,REFRIGERA... $0 -$600 May 30, 2014
Mar 1, 2014 32073543M RESOLVE CLASS - 2 B201,50. 50-WORK W/O A PERMIT- LOCHINVAR BOILER IS BEING INSTALLED W/OA PERMIT. OBTAIN PROPER PERMIT. $800 $0 Apr 18, 2014
Feb 19, 2014 35085159P RESOLVE CLASS - 3 WORK W/O A PERMIT. AT 4TH STORY APT DESIGNATED 23A ERECTED FULL HEIGHTPARTITION APPRX 12 LINEAR FEET LONG. RMDY: OBTA... $230 $0 Apr 18, 2014
Jan 21, 2014 35078336L RESOLVE CLASS - 3 WORK W/O A PERMIT. FLR TO CEILING PARTITION ERECTED INSIDE APT #30B TOCREATE ADDITIONAL SPACE/ROOM. REMEDY: OBTAIN PE... $0 $0 Mar 21, 2014
Sep 20, 2013 32073793P RESOLVE CLASS - 1 B154,16,43,49,50A,B. 50A- CLOGGED CHIMNEY BASE. 50B- IMPROPER COMBUSTION, BOILER EMITTING BLACK FUMES W/SOOT ALL OVER... $1,000 $0 Nov 15, 2013
Dec 3, 2012 32072149J RESOLVE CLASS - 2 B254,21A,50A,B,C,D,E,F,G,H,I. 50A- COVERS MISSING ON CONTROLS. 50B-OILLEAK AT BURNER. 50C- SUPPLY PUMP CANNOT RUN. CO... $0 $0 Jan 18, 2013
Sep 25, 2012 34995598N RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.DEFECT NOTED:AT BASEMENT LEVEL SIDE ENTRANCE TO APTS C&D DOOR STRIC... $0 $0 Nov 16, 2012
Nov 2, 2011 32071416K RESOLVE CLASS - 2 16 34AB 50A-DEFECTIVE DRAFT REGULATOR $500 $0 Mar 30, 2012
Jul 11, 2011 34912133R RESOLVE CLASS - 3 WORK W/O A PERMIT NOTED:@ 3RD STORY,APT 18A,SOUTH EAST SECTION OF BLDG,ERECTED SHEETROCK INTERIOR PARTITION TO SUBDIV... $200 $0 Sep 2, 2011
Jul 21, 2007 32054422M RESOLVE Non-Hazardous B4A-48A,50ABC.50A-PIPE HOT WATER RELIEF DISCHARGE DOWN NO THREADED END.50B-FLUE PIPE NOT PROPERLY SEALED TO CHIMNEY.5... $180 $0 Nov 16, 2007
Apr 3, 2007 32053286M RESOLVE Non-Hazardous B4A,34A,50A,50B.50A-NEED SUPPORT ON FLUE PIPE.50B-HOLES ON THE WALLS. $180 $0 Jun 1, 2007
Sep 19, 2001 34289573Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL NOTED APPROX 30 TO 40 FEET OF COPING ON PARARET WALL MISSING GRACKED SPALL... $2,500 $0 Nov 2, 2001