ECB violations
Merriam Avenue, Bronx • Block 02534 • Lot 0008
112 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 5, 2012 | 38223063M | RESOLVE | CLASS - 1 | 21I11,100I11,97X10,14M7. 21-REPLACE DOOR LOCK IN LOBBY. 100-REPLACE RELEASE ROLLER & ARM. 87-RESTORE ELEVATOR TO SERV... | $1,000 | -$500 | Mar 1, 2013 |
| Aug 15, 2012 | 38223042N | RESOLVE | CLASS - 1 | 97X10;ONE OF TWO ELEVATOR IN A 18 STORY BLDG IS OUT OF SERVICE THERE BY CAUSING CONDITION DANGEROUS TO HUMAN LIFE THI... | $10,000 | $0 | Dec 14, 2012 |
| Aug 1, 2012 | 38222689J | RESOLVE | CLASS - 1 | 97X10;REPAIR IMMEDIATELY FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:SERVICE EQUIPMENT ELEVATOR PER BC 3001... | $1,000 | $0 | Oct 5, 2012 |
| Aug 1, 2012 | 38222688H | RESOLVE | CLASS - 1 | 97X10:REPAIR IMMEDIATELY FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:SERVICE EQUIPMENT ELEVATOR PER BC 3001... | $1,000 | -$800 | Oct 5, 2012 |
| Jul 13, 2012 | 38222198P | RESOLVE | CLASS - 2 | 67X10,14M10. | $500 | $0 | Aug 31, 2012 |
| Jul 13, 2012 | 38222197N | RESOLVE | CLASS - 2 | 97X10. 97:ONE OF TWO ELEVATORS IN THE BUILDING IS OUT OF SERVICE; RESTORE TO SERVICE. | $500 | $0 | Aug 31, 2012 |
| Jan 11, 2012 | 38220407N | RESOLVE | CLASS - 2 | 29Q03,39O02,39Q03,56Y13,60Q03,34O02,67M07,70O02,71X10,71Q03,73O02,74O02,76Q03,77Q03,97O02,100X10: 39Q03-INSTALL GUARD... | $250 | $0 | Mar 2, 2012 |
| Jan 11, 2012 | 38220406L | RESOLVE | CLASS - 2 | 02X10,32I11,34O02,35Q03,39O02,39Q03,42D06,52M07,60Q03,67M07,70O02,71X10,71Q03,73O02,74O02,76Q03,77Q03,97O02,100X10: 3... | $250 | $0 | Mar 2, 2012 |
| Dec 1, 2010 | 34891386P | RESOLVE | CLASS - 2 | ALTERED CHANGED BLDG OCCUPIED W/O A VALID CERT OF OCCUPANCY NOTED PREMISES ALTERED UNDER PERMIT #200444171 AND NOW OC... | $2,500 | $0 | Apr 22, 2011 |
| Jun 25, 2010 | 34851102H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. FOUND THAT ADDRESS ABOVE HAS AREA DRAINS ABOVE PARKING GARAGE ... | $2,500 | $0 | Jul 13, 2012 |
| Jun 12, 2010 | 34856164X | RESOLVE | CLASS - 1 | UNLAWFUL ACTS. FAILURE TO COMPLY W/ AN ORDER OF THE COMMISSIONER. RESPONDENT FAILED TO CORRECT THE CONDITION(S) CITED... | $12,000 | $0 | Jul 13, 2012 |
| Feb 24, 2010 | 38209387H | RESOLVE | CLASS - 2 | 14I7.17H7.53B14.100H7.17H7 HOISTWAY DOOR GIBS ARE WORN REPLACE WERE NEEDED 100H7 CAR DOOR SADDLE IS VERY WORN PROVIDE | $500 | $0 | Jun 4, 2010 |
| Feb 24, 2010 | 38209386X | RESOLVE | CLASS - 2 | 14I7.17H7.100H7 17H07 HOISTWAY DOOR GIBS ARE WORN REPLACE WERE NEEDED 100H7 CAB DOOR SADDLE IS VERY WORN PROVIDE | $500 | $0 | Jun 4, 2010 |
| Jan 15, 2010 | 34812024J | RESOLVE | CLASS - 1 | WORK W/O PERMIT. WORK NOTED: AT 2ND FLR PARTITIONS WERE ERECTED TO CREATE 5 ADDITIONAL APTS. THE REC AND LAUNDRY ROOM... | $8,000 | $0 | Jul 13, 2012 |
| Jan 15, 2010 | 34812023H | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O. C OF O #43995 INDICATES THAT THE 2ND FLR HAS RECREATION ROOM,LAUNDR... | $12,000 | $0 | Jul 13, 2012 |
| Dec 18, 2009 | 34812028R | RESOLVE | CLASS - 2 | ALTERED CHANGE BLDG OCCUPIED W/O A VALID C OF O AS PER 28-1183.1-28-118.3.2 NOTED JOB 200444171 PERMIT ISSUED 6/19/06... | $2,500 | $0 | Jul 13, 2012 |
| Oct 19, 2009 | 38206907Z | RESOLVE | CLASS - 2 | 05J1.17H10.05J1 ADJUST GAP CAB DOOR AND RETURN POST 17H10 HOISTWAY DOOR ARE WORN REPLACE WERE NEED | $2,500 | $0 | Jul 13, 2012 |
| Jul 9, 2009 | 34786862M | RESOLVE | CLASS - 2 | WORK W.O PERMIT. WORK NOTED: AT 16 STORY LEVEL, APT 16C, FRONT RIGHT SECTION OF BLDG, A CLASS "A" APT FULL HEIGHT PAR... | $4,000 | $0 | Jul 13, 2012 |
| May 15, 2009 | 34760066X | RESOLVE | CLASS - 2 | WORK W/O PERMIT. WORK NOTED: AT APT #10A,A PARTITION WAS ERECTED FROM FLR TO CEILING TO CREATE A BEDROOM. PARTITION W... | $4,000 | $0 | Jul 24, 2009 |
| Feb 7, 2009 | 38201045L | RESOLVE | CLASS - 2 | 16B11,17H11,05B01,26D06,25D06,100H10,70O02. (16-B-01) ADJUNT ALL HATCH DOOR LOBBY TO 18TH FLOOR TO OPEN & CLOSE PROPE... | $2,500 | $0 | Apr 3, 2009 |
| Feb 7, 2009 | 38201044J | RESOLVE | CLASS - 2 | 97X10 97X10 RETURN ELEVATOR TO SERVICE CALL DOB AT 212 566-5544 WHEN ELEVATOR IS BEING RESTORE TO SERVICEFOR PROPER I... | $2,500 | $0 | Apr 3, 2009 |
| Jan 26, 2009 | 38200552L | RESOLVE | CLASS - 2 | 100B10.100 RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE BY THISDEPT | $2,500 | $0 | Mar 20, 2009 |
| Jan 16, 2009 | 38200246N | RESOLVE | CLASS - 2 | 57I10 62O2 70O2 57I10 REPAIR DAMAGED BRUSH RIGGING ON HOIST MOTOR ALSO REPAIR WIRES COMING OFF FIELDS IN MOTOR RETURN... | $2,500 | $0 | Mar 20, 2009 |
| Dec 22, 2008 | 38199693J | RESOLVE | CLASS - 2 | 97X10.97X10-RETURN ELEVATOR TO SERVICE | $2,500 | $0 | Feb 20, 2009 |
| Oct 28, 2008 | 38191532M | RESOLVE | CLASS - 2 | 99B05,26D06,10A11,17H11,33O02,39O02,40O02,68M07,70O02,73O02,74O02,02B11. | $2,500 | $0 | Dec 19, 2008 |
| Oct 28, 2008 | 38191531K | RESOLVE | CLASS - 2 | 100B10,10H11,98M07,26D06,17H11,34O02,35O02,39O02,68M07,70O02,73O02,74O02. 100-RESTORE TO SERVICE SO FULL INSPECTION C... | $2,500 | $0 | Dec 19, 2008 |
| Aug 27, 2008 | 34695827N | RESOLVE | CLASS - 3 | WORK W/O A PERMIT WORK NOTE IN APT 16C CREATED PARTITION FROM 2 BEDROOM INTO 3 BEDROOM OFF THE KITCHEN CREATED 3 BEDR... | $500 | $0 | Oct 17, 2008 |
| Mar 18, 2008 | 38182839M | RESOLVE | Non-Hazardous | 16J01.09A10.31H02.05J01.44B10.38O02.66O02.34D06. 16J01 ADJUST GAP IN LOBBY CAB DOOR 09A10 REPAIR CAB FL TO BE LEVEL T... | $0 | $0 | May 16, 2008 |
| Mar 18, 2008 | 38182840J | RESOLVE | Non-Hazardous | 05B01.31H01.34D06.38O02.66O02.84I11. 05B01 DJUST CAB DOOR TO OPEN PROPERLY DOOR SLAMS TO OPEN 31H01 ADJUST GUIDE ROLL... | $0 | $0 | May 16, 2008 |
| Jun 27, 2007 | 38167638K | RESOLVE | Non-Hazardous | 31J01,38O02,66O02.31J01-ADJUST CAR ROLLERS.38O02-CLEAN CAR TOP.66O02-CLEAN PIT. | $2,500 | $0 | Jun 15, 2012 |
| Jun 27, 2007 | 38167637Z | ACTIVE | Non-Hazardous | 05H11,31H11,38O02,66O02,41G07,09A10.05H11-REPLACE WORN CAB DOOR ROLLER.31H11-REPLACE WORN GUIDE ROLLERS WHERE NEEDED.... | $2,500 | $0 | Jul 13, 2012 |
| Apr 19, 2007 | 38166231Y | RESOLVE | Non-Hazardous | 31H11,9R11,27 10,5L10,12L10.9/R-FL IS TO HIGH.5/L-GAP BETWEEN CAR DOOR& CAR ENCLOSURE.12/L-ALL LIGHTS HAVE TO WORK. | $2,500 | $0 | Aug 17, 2007 |
| Apr 19, 2007 | 38166230M | RESOLVE | Non-Hazardous | 31H11,9R11,271110,5L10,12L10. 9/R FL IS TO HIGH. 5/L GAP BETWEEN CAR DOOR & CAR ENCLOSURE. 12/L ALL LIGHTS HAVE TO WORK. | $2,500 | $0 | Aug 17, 2007 |
| Aug 11, 2006 | 34550363R | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A 5TH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS: PERIODIC INSP OF EXTERIOR WALLS & AP... | $1,750 | $0 | Nov 3, 2006 |
| May 19, 2006 | 34549801J | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS:PERIODIC INSP OF EXTERIOR WALLS &... | $0 | $0 | Jul 7, 2006 |
| Feb 28, 2006 | 34549337P | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... | $1,750 | $0 | Jul 28, 2006 |
| Jul 29, 2005 | 34459037Y | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A 5TH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WA... | $1,750 | $0 | Jul 28, 2006 |
| Mar 18, 2005 | 34461352R | RESOLVE | Non-Hazardous | 20050805YDE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED BY LOCAL LAW 11 OF 1998 A... | $1,750 | $0 | Nov 3, 2006 |
| Sep 8, 2004 | 38148980M | RESOLVE | Non-Hazardous | 01I10,25A10,31H10,05J10,66O02,04A10,86U05,33O02,51B07.05-EXESSIVE GHP AT RETURN POST.04 AND 25 A-REPAIR TO MEET CODE ... | $2,500 | $0 | Oct 22, 2004 |
| Jul 23, 2004 | 34459794L | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $1,750 | $0 | Sep 24, 2004 |
| May 5, 2004 | 34460438N | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPUTENANCES AS REQUIRED B... | $700 | $0 | Sep 24, 2004 |
| Apr 7, 2004 | 34408415M | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR OF BLDG ISSUES :-EAST ELEVATION;EXTENSIVE DETERIORTING CRACKS AND SPALLING IN BALCONIES;... | $800 | $0 | Jan 21, 2005 |
| Dec 12, 2003 | 34462496K | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OR EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $700 | $0 | Jan 21, 2005 |
| Jun 23, 2003 | 34396945Y | RESOLVE | Non-Hazardous | WORK W/O PERMIT WORK NOTED HAVING INSTALLED PARTITIONS WALL IN DINING ROOM AREA TO CREATE A BEDROOM CONVERTED 2 BEDRO... | $500 | $0 | Feb 6, 2004 |
| Jun 5, 2003 | 34396928M | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT: WORK NOTED: IN APT 4C INSTALLED PARTITIONS IN THE DINING ROOM AND CHANGE ROOM COUNT FROM 2 BED... | $500 | $0 | Feb 6, 2004 |
| Jun 2, 2003 | 34386721X | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. WORK NOTED:(1) HAVING INSTALLED PARTITION IN APT 2-F TO CREATE A 2 BEDROOM APARTMENT AT FRONT ... | $500 | $0 | Feb 6, 2004 |
| Dec 24, 2002 | 38134581H | RESOLVE | Non-Hazardous | 02B11/ 62O02/ 31O02/ 36O02/ 11D06/ 10H12/ 05J01/ 03H12/ 23D06/ 52O02/ 49B15/ 17H12/ 02=VERY LOW. 05=EXCESSIVE GAP AT ... | $350 | $0 | Feb 7, 2003 |
| Dec 24, 2002 | 38134580X | RESOLVE | Non-Hazardous | 11D06/ 36O02/ 23D06/ 62O02/ 60L11/ 31O02/ 52O02/ 42#09/ 49B15/ 04B07/ 17H12/ 60=LIGHT SWITCH. 42=CHECK FOR AND REMOVE... | $350 | $0 | Feb 7, 2003 |
| Nov 30, 1998 | 34188607P | RESOLVE | Hazardous | FAILUR ETO FILE AN AMENDED ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R C N Y 32-03B 5 INDICATING CO... | $0 | $0 | Mar 26, 1999 |
| Nov 10, 1998 | 34188522X | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND THREE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R C N Y 32-03B 5 INDICAT... | $0 | $0 | Mar 26, 1999 |