| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 20, 2026 | 37036848M | ACTIVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8C AND 9C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INI... | $1,250 | $1,250 | Aug 21, 2026 |
| Nov 7, 2024 | 39534198Y | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF 6 STORY RESIDENTIAL BUILDING OBSERVED SIDEWALK SHED IN PLACE FOR FACADE WORK NOT MAINTAINED ... | $6,000 | $6,000 | Sep 19, 2025 |
| Nov 7, 2024 | 39534199X | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF 6 STORY RESIDENTIAL BUILDING OBSERVED DEBRIS CONTAINER IN STREET WITHOUT THE PROPER SIGNS/BA... | $2,500 | $2,500 | Mar 21, 2025 |
| Oct 18, 2024 | 39533574Y | RESOLVE | CLASS - 2 | AT TIME OF MY INSPECTION OF A 6 STORY BUILDING. I NOTICED A SIDEWALK SHED WITH FULL OF CONSTRUCTION DEBRI ON DECK AND... | $2,400 | $2,400 | May 7, 2026 |
| Feb 27, 2024 | 39525894N | RESOLVE | CLASS - 2 | OBSERVED AT 530AM MUDSILL SUPPORTING VERT MEMBERS CRACK OR MISSING EXP1,SECTION OF CATCHALL MISSING AND SWS DECK NOT ... | $2,400 | $2,400 | Feb 25, 2025 |
| Dec 13, 2023 | 39101332M | RESOLVE | CLASS - 2 | FOUND HB SMITH 28 SERIES BOILER TO HAVE LEAKING RETURNS ON REAR OF BOILER, BOILER ROOM DOOR NOT SELF CLOSING, CONDENS... | $0 | $0 | Feb 16, 2024 |
| Feb 22, 2023 | 39513387K | RESOLVE | CLASS - 2 | REINSPECTION OF SWS FOR CM2331176 OBSERVED VIOLATING CONDITINOS STILL EXIST. REVIEW APPLICATION X00037722 DOBNOW PERM... | $1,250 | $1,250 | Jun 2, 2023 |
| Feb 1, 2023 | 35662206X | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL(S) OR APPURTENANCES.NOTE:AT TIME OF INSPECTION OBSERVED CRACK SPALLING DET... | $1,250 | $0 | Aug 28, 2023 |
| Feb 1, 2023 | 35662205Y | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.NOTE:AT TIME OF INSPECTION OBSERVED 6 STORY BUILDING SIDEWALK... | $2,400 | $0 | Apr 21, 2023 |
| Feb 1, 2023 | 35662204M | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT.NOTE:AT TIME OF INSPECTION OBSERVED 6 STORY BUILDING SIDEWALK... | $1,250 | $0 | Apr 21, 2023 |
| Feb 9, 2022 | 35639931N | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE PEDESTRIAN PROTECTION.ATO OF MY INSP I OBSERVED SWS@6STYB.SWS DOESNT MEET CODE.SWS SUPPORTED POST ... | $5,000 | $0 | May 6, 2022 |
| Feb 9, 2022 | 35639932P | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE PEDESTRIAN PROTECTION.ATO MY INSP I OBSERVED SWS@6STYB.SWS HAS POOR MAINTENANCE I NOTICED ROTTED W... | $5,000 | $0 | May 6, 2022 |
| Feb 9, 2022 | 35639930L | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE PEDESTRIAN PROTECTION ATO MY INSP OF SWS@6STY OCCUPIED BLDG.SWS DOESNT MEET CODE IT ISNT FULY EXTE... | $5,000 | $0 | May 6, 2022 |
| Feb 9, 2022 | 35639929Y | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE PEDESTRIAN PROTECTION.ATO MY INSP OF SWS@OCCUPIED 6STYB.I NOTICED SWS W/MISSING PARAPET PANEL THAT... | $5,000 | $0 | May 6, 2022 |
| Feb 6, 2022 | 35582002Y | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.NOTED AT TIME OF INSPECTION,SIDEWALK SHED IS MISSING 1 PARAPE... | $5,000 | $0 | Sep 16, 2022 |
| Nov 16, 2019 | 38272262X | RESOLVE | CLASS - 2 | 02B10,70P16,03M07,16B10 - 02B#-REPAIR IN CAR PHONE, 70P#-PROVIDE KEY ON LOCATION TO ACCESS INSPECTION AREAS 03M#-PROV... | $625 | $0 | Feb 28, 2020 |
| Jun 18, 2019 | 37015309K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #38264982Y ISSUED ON 8/29/18,AND TO FI... | $1,250 | $0 | Sep 6, 2019 |
| Aug 29, 2018 | 38264982Y | RESOLVE | CLASS - 2 | 05J01,40P16. 05J01-DOOR OF CAB IS MISALIGNED ADJUST; 50P16-MOTOR DOORIS LOCKED NO ACCESS, PROVIDE ACCESS. | $625 | $0 | Oct 19, 2018 |
| Apr 18, 2018 | 35318669J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BLDG FACADE AND APPURTENANCES. NOE 1-CRACK/SPALLED/DETERIORATED TERRA COTTA AT LINTELS W... | $0 | $0 | Sep 14, 2018 |
| Apr 18, 2018 | 35318668H | RESOLVE | CLASS - 1 | FAILURE TO TAKE PROVIDE SAFETY MEASURE. SUCH AS SIDEWALK SHEDS, FENCE ETC. WHERE REQUIRE TO PROTECT AND SECURE PUBLIC... | $0 | $0 | Sep 14, 2018 |
| Jan 5, 2018 | 32092714L | ACTIVE | CLASS - 2 | 50A-E. AS PER CLASS 2 (B254) 28.301.1 FAILURE TO MAINTAIN. (50A)HOT WATER PIPING BETWEEN COIL & MIXING VALVE BADLY CO... | $2,500 | $0 | Apr 6, 2018 |
| Feb 21, 2014 | 38230107K | RESOLVE | CLASS - 2 | 41I10,16E01,70Z09,71L11,39I11. 41I- MOTOR ROOM DOOR OFF HINGE DAMAGED REPAIR. 16E- HOISTWAY DOORS RUBBING ADJUST. 70Z... | $250 | $0 | Apr 18, 2014 |
| Jun 11, 2012 | 38222279R | RESOLVE | CLASS - 1 | SEC. 28-116.4.1. 44R11,52R11,97R07. 97R- OPERATING DEVICE W/O A C/C, NO REPORT OF INSPECTION SUBMITTED TO DOB & NO WI... | $0 | $0 | Jan 3, 2013 |
| Jan 15, 2012 | 36018232Z | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/CODE PROVISIONS: PERIODIC INSPECTION OF EXTER... | $2,000 | $0 | Jul 27, 2012 |
| Apr 15, 2011 | 36016629H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... | $2,000 | $0 | Dec 2, 2011 |
| Jul 14, 2010 | 36013610Y | RESOLVE | CLASS - 2 | FAIL TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS. PERIODIC INSPECTION OF EX... | $4,000 | $0 | Sep 3, 2010 |
| Jul 12, 2010 | 36014027L | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... | $2,000 | $0 | Mar 4, 2011 |
| Apr 28, 2010 | 34819896Z | RESOLVE | CLASS - 1 | SEC BC 3301.2 (MISC) FAIL TO PROVIDE TO 3'6" GUARD RAIL OR EQUIVALENT AROUND ALL FLOOR & PERIMETER OPENINGS. NOTED: W... | $8,000 | $0 | Jul 23, 2010 |
| Apr 28, 2010 | 34819897K | RESOLVE | CLASS - 2 | FAIL TO PROVIDE APPROVED/ACCEPTED PLANS AT JOBSITE AT TIME OF INSPECTION. NOTED: WORK ONGOING UNDER ALT 2 PERMIT 2200... | $2,500 | $0 | Jul 23, 2010 |
| Mar 22, 2010 | 34820221Z | ACTIVE | CLASS - 2 | STP ALL WORK 5& 6 FLOOR FAILURE TO MAINTAIN BLDG WALLS OR APPURTANENCES AT TIME OF INSPECTION I DID OBSERVED 6TH FLR ... | $2,500 | $0 | Dec 3, 2010 |
| Oct 23, 2009 | 36009998H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXT... | $4,000 | $0 | Jan 8, 2010 |
| Jan 30, 2009 | 36007983X | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... | $4,000 | $0 | Sep 18, 2009 |
| Jun 22, 2007 | 38166765Z | RESOLVE | Hazardous | 02X11,84X11,84X11,39P07,64R09,66Z09,17L11,16I11.84-EMERGENCY COMMUNICATION.84-FIRE SERVICE PARTS.64-LIGHT NOT AS PER ... | $500 | $0 | Aug 17, 2007 |
| Jan 19, 2005 | 38156572N | RESOLVE | Non-Hazardous | 31H11/14M7/55Y13/41Q3/60T15/39T15/12L11/37I11/66Z9/66I13 41 COVER TROFFING IN CONTROLLER 12-TOP AND BOTTOM 37 TRAVELI... | $2,500 | $0 | Oct 21, 2005 |
| Jul 23, 2004 | 34459796P | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $1,750 | $0 | Jan 21, 2005 |
| Dec 12, 2003 | 34462503J | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OR EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $700 | $0 | Jan 21, 2005 |
| Feb 9, 2002 | 38121405X | RESOLVE | Non-Hazardous | 50Y14-52O02. | $2,500 | $0 | Apr 5, 2002 |
| Apr 4, 2000 | 34239501Y | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYINGTO THE INSTALLATION OF REQUIRED FIRE PROTECTION... | $2,500 | $0 | May 26, 2000 |
| Apr 4, 2000 | 34239502X | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ELEVATOR LANDING SIGNS "IN CASE OF FIRE, USE STAIRSUNLESS OTHERWISE INSTRUCTED" ON ALL FLOORS. FAI... | $5,000 | $0 | May 26, 2000 |
| Nov 5, 1998 | 38081257J | RESOLVE | Non-Hazardous | 14M,21X,73,57O. NO CERTIFATE FRAME, NO INDICATORR WORKING, ROUGHT RIDE UP AND DOWN MOTION USED ADJUSTMENT, PIT DIRTY. | $350 | $0 | May 14, 1999 |
| Jan 23, 1998 | 38069566L | RESOLVE | Non-Hazardous | 14M,28L,05E,32Q,57O,18Q,03K,26Q,57Z,46Q, 5E-CAB DOOR RUBBING 03K-REPAIR SHEET METAL UNDER CAR. | $2,500 | $0 | Jun 26, 1998 |
| Mar 4, 1991 | 38007846M | RESOLVE | Non-Hazardous | 02L;03I;07;35O;57O; | $1,000 | $0 | Aug 9, 1991 |