680-702 East 139 Street, Bronx • Block 02567 • Lot 0013

16 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jun 13, 2025 39150965N ACTIVE CLASS - 2 I FOUND A WEIL MCLAIN HOT WATER BOILER THAT THE AIR FAN PROOVING SWITCH WAS NOT WORKING PROPELY/CORRECT ALL VIOLATING... $1,250 $0 Jul 4, 2025
Aug 21, 2023 39092983Y RESOLVE CLASS - 2 FOUND PIPING ON HOT WATER COILS CORRODED, ON HEADER SUPPLY LINE 3 WAY MODULATING VALVE CORRODED AND LEAKING. $625 $0 Oct 20, 2023
Aug 21, 2023 39092999Z RESOLVE CLASS - 2 OBSERVED IN BASEMENT/CELLAR 2 ACTIVE LEAKS ONE IS IN THE BOILER ROOM AND THE OTHER IN ON CAST IRON PIPE IN THE WATER ... $625 $0 Oct 20, 2023
Mar 13, 2023 39081439R RESOLVE CLASS - 2 OBSERVED ACTIVE LEAK IN THE SPRINKLER CONTROL ROOM ON THE CAST IRON PIPING OR FITTING. AS PER PC 102.3 MAINTENANCE. I... $625 $0 Mar 27, 2023
Mar 13, 2023 39081438P RESOLVE CLASS - 2 OBSERVED LIGHT FIXTURES ON 2ND AND 3RD FLOORS OBSTRUCTING SPRINKLER HEADS., REPAIR AND/OR REPLACE $625 $0 Mar 27, 2023
Dec 10, 2020 39033269R RESOLVE CLASS - 2 COMBUSTION AIR FAN NOT FUNCTIONING-UNCAPPED HW PIPING AT STRAINERS UNDER HW PUMPS-DISCONNECT BOX FOR CIRCULATOR NOT P... $0 $0 Dec 30, 2020
Mar 16, 2020 39019735Y RESOLVE CLASS - 1 PROVIDE PRINTS FOR THE CONTROLLER IN MACHINE ROOM. NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED B... $1,250 $0 Apr 8, 2020
Nov 1, 2019 39012234Y RESOLVE CLASS - 1 LEAK FROM BOILER FLOODING BOILER ROOM FLOOR; CORRECT ALL VIOLATING CONDITIONS AND CALL FOR AN INSPECTION. $1,250 $0 Nov 12, 2019
Jan 4, 2019 38267094J RESOLVE CLASS - 2 71X10, 72D6, 72M7. 71X10-PIT LIGHT NOT WORKING REPAIR. 72D6-EMERGENCYSTOP SWITCH IN PIT NEEDS TO BE SECURED; 72M7-PRO... $0 $0 Apr 5, 2019
Nov 9, 2011 38219048M RESOLVE CLASS - 2 19M07 39Q03 67M07 69M07 77Q03 19M-PROVIDE FIRE GIBBS FOR HOISTWAY DOORS 39Q-INSTALL GUARD FOR LIGHT TOP OF CAR 67M-PR... $0 $0 Dec 30, 2011
May 28, 2010 38211172N RESOLVE CLASS - 2 39Q03,40R09,69M07,77X10,77Q03,39-Q-03 INSTALL GUARD FOR LIGHT ON TOP OF CAR,40-R-09 REMOVE ALL NON ELEVATOR ITEM FROM... $500 $0 Oct 22, 2010
Dec 29, 1999 38093301X RESOLVE Non-Hazardous 11X,22L,43R. $0 $0 Feb 25, 2000
Mar 4, 1993 38030903P RESOLVE Non-Hazardous 73X, 73.RESTORE ELEVATOR SERVICE SO PROPER INSPECTION CAN BE MADE BY THIS DEPT. $0 $0 Apr 2, 1993
Aug 20, 1991 34059549P RESOLVE Non-Hazardous NEW BUILDING OCCUPIED WITHOUT A VALID CERFICATE OF OCOCUPANCY NEW BUILDING 53-88 C OF O. 60431 EXPIRED 6/20/91 REMEDY... $0 $0 Nov 15, 1991
Sep 27, 1989 34022479J RESOLVE Hazardous FAILURE TO FILE 10E CONTROLLED INPSECTION REPORTS FOR SUBGRADE AND SHEETING, SHORING, BRACING AND UNDERPINNING AS REQ... $0 $0 Dec 1, 1989
Nov 22, 1988 34007124P RESOLVE Hazardous FAILURE TO PROTECT ADJOINING STRUCTURES DURING EXCAVATION OPERATIONS AT CENTER EAST. SUBIT A REPORT BY A P.E. OR R.A.... $0 $0 Dec 1, 1989