ECB violations
680-702 East 139 Street, Bronx • Block 02567 • Lot 0013
16 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 13, 2025 | 39150965N | ACTIVE | CLASS - 2 | I FOUND A WEIL MCLAIN HOT WATER BOILER THAT THE AIR FAN PROOVING SWITCH WAS NOT WORKING PROPELY/CORRECT ALL VIOLATING... | $1,250 | $0 | Jul 4, 2025 |
| Aug 21, 2023 | 39092983Y | RESOLVE | CLASS - 2 | FOUND PIPING ON HOT WATER COILS CORRODED, ON HEADER SUPPLY LINE 3 WAY MODULATING VALVE CORRODED AND LEAKING. | $625 | $0 | Oct 20, 2023 |
| Aug 21, 2023 | 39092999Z | RESOLVE | CLASS - 2 | OBSERVED IN BASEMENT/CELLAR 2 ACTIVE LEAKS ONE IS IN THE BOILER ROOM AND THE OTHER IN ON CAST IRON PIPE IN THE WATER ... | $625 | $0 | Oct 20, 2023 |
| Mar 13, 2023 | 39081439R | RESOLVE | CLASS - 2 | OBSERVED ACTIVE LEAK IN THE SPRINKLER CONTROL ROOM ON THE CAST IRON PIPING OR FITTING. AS PER PC 102.3 MAINTENANCE. I... | $625 | $0 | Mar 27, 2023 |
| Mar 13, 2023 | 39081438P | RESOLVE | CLASS - 2 | OBSERVED LIGHT FIXTURES ON 2ND AND 3RD FLOORS OBSTRUCTING SPRINKLER HEADS., REPAIR AND/OR REPLACE | $625 | $0 | Mar 27, 2023 |
| Dec 10, 2020 | 39033269R | RESOLVE | CLASS - 2 | COMBUSTION AIR FAN NOT FUNCTIONING-UNCAPPED HW PIPING AT STRAINERS UNDER HW PUMPS-DISCONNECT BOX FOR CIRCULATOR NOT P... | $0 | $0 | Dec 30, 2020 |
| Mar 16, 2020 | 39019735Y | RESOLVE | CLASS - 1 | PROVIDE PRINTS FOR THE CONTROLLER IN MACHINE ROOM. NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED B... | $1,250 | $0 | Apr 8, 2020 |
| Nov 1, 2019 | 39012234Y | RESOLVE | CLASS - 1 | LEAK FROM BOILER FLOODING BOILER ROOM FLOOR; CORRECT ALL VIOLATING CONDITIONS AND CALL FOR AN INSPECTION. | $1,250 | $0 | Nov 12, 2019 |
| Jan 4, 2019 | 38267094J | RESOLVE | CLASS - 2 | 71X10, 72D6, 72M7. 71X10-PIT LIGHT NOT WORKING REPAIR. 72D6-EMERGENCYSTOP SWITCH IN PIT NEEDS TO BE SECURED; 72M7-PRO... | $0 | $0 | Apr 5, 2019 |
| Nov 9, 2011 | 38219048M | RESOLVE | CLASS - 2 | 19M07 39Q03 67M07 69M07 77Q03 19M-PROVIDE FIRE GIBBS FOR HOISTWAY DOORS 39Q-INSTALL GUARD FOR LIGHT TOP OF CAR 67M-PR... | $0 | $0 | Dec 30, 2011 |
| May 28, 2010 | 38211172N | RESOLVE | CLASS - 2 | 39Q03,40R09,69M07,77X10,77Q03,39-Q-03 INSTALL GUARD FOR LIGHT ON TOP OF CAR,40-R-09 REMOVE ALL NON ELEVATOR ITEM FROM... | $500 | $0 | Oct 22, 2010 |
| Dec 29, 1999 | 38093301X | RESOLVE | Non-Hazardous | 11X,22L,43R. | $0 | $0 | Feb 25, 2000 |
| Mar 4, 1993 | 38030903P | RESOLVE | Non-Hazardous | 73X, 73.RESTORE ELEVATOR SERVICE SO PROPER INSPECTION CAN BE MADE BY THIS DEPT. | $0 | $0 | Apr 2, 1993 |
| Aug 20, 1991 | 34059549P | RESOLVE | Non-Hazardous | NEW BUILDING OCCUPIED WITHOUT A VALID CERFICATE OF OCOCUPANCY NEW BUILDING 53-88 C OF O. 60431 EXPIRED 6/20/91 REMEDY... | $0 | $0 | Nov 15, 1991 |
| Sep 27, 1989 | 34022479J | RESOLVE | Hazardous | FAILURE TO FILE 10E CONTROLLED INPSECTION REPORTS FOR SUBGRADE AND SHEETING, SHORING, BRACING AND UNDERPINNING AS REQ... | $0 | $0 | Dec 1, 1989 |
| Nov 22, 1988 | 34007124P | RESOLVE | Hazardous | FAILURE TO PROTECT ADJOINING STRUCTURES DURING EXCAVATION OPERATIONS AT CENTER EAST. SUBIT A REPORT BY A P.E. OR R.A.... | $0 | $0 | Dec 1, 1989 |