Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 21, 2019 38271219X RESOLVE CLASS - 1 RTS 97.X.17,99.M.07,61.T.07,59.BB.07,60.X.10,41.I.10,42.M.07,68.M.07,68.M.07=(97.X.17) RETURN TO SERVICE RECURRING CO... $0 $0 Oct 18, 2019
Apr 30, 2019 38269443H RESOLVE CLASS - 1 97-X-17=REPAIR AND RESTORE TO SERVICE IMMEDIATELY AND NOTIDY NYC DOB REPAIR SO ON REINSPECTION CAN BE PERFORM $3,125 $0 Jun 21, 2019
Aug 1, 2018 35324513Y RESOLVE CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS AS PER 3307.6.4.4.5. NOTE: @ TIME OF INSP OBSERVED SIDEWALK S... $0 $0 Sep 26, 2018
Aug 1, 2018 35324514X RESOLVE CLASS - 2 FAILURE TO OBTAIN PERMIT FOR TEMPORARY CONSTRUCTION EQUIPMENT. NOTE: @TIME OF INSP OBSERVED CONSTRUCTION FENCE IN PLA... $620 $0 Sep 21, 2018
May 18, 2018 37010630Y RESOLVE CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... $625 $0 Jan 11, 2019
Apr 17, 2018 35323759J RESOLVE CLASS - 2 EXPIRED PERMIT FOR TEMPORARY CONSTRUCTION EQUIPMENT. NOTE: AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE WI... $1,250 $0 Jun 15, 2018
Mar 23, 2018 35323628J RESOLVE CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT. NOTE: OBSERVED SIDEWALK SHED IS IN PLACE W/EXPIRED PERMIT. P... $3,125 -$3,125 May 18, 2018
Mar 23, 2018 35323627H RESOLVE CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION #3307.6.4.8. NOTE: OBSERVED SIDEWALK SHED LIGHTS ARE NOT OPERA... $5,000 $2,570 May 18, 2018
Mar 22, 2017 38253239Y RESOLVE CLASS - 1 CU-05A10,69M7,59B7,68B7,68M7,70Z9. CU05A10-DOOR ZONE RESTRICTOR INOPERATIVE.THIS IS A SAFETY DEVICE TO ENSURE ELEVATO... $1,000 $0 May 19, 2017
Mar 3, 2017 35200548J RESOLVE CLASS - 2 FAILURE TO PROVIDE SIDEWALK SHED PARAPET SIGN ACCORDING TO 3301.9.2. NOTED: AT TIME OF INSPECTION SIDEWALK SHED PARAP... $0 $0 Apr 21, 2017
Mar 3, 2017 35200547H RESOLVE CLASS - 2 SCAFFOLD CERTIFICATE CARD NOT READLY AVAILABLE FOR INSPECTION. NOTED: AT TIME OF INSPECTION FOLLOWING WORKERS: HECTOR... $0 $0 Jun 2, 2017
Mar 3, 2017 35200546X RESOLVE CLASS - 2 PARTIAL SWO ISSUED FOR SUSPENDED SCAFFOLD PURSUANT 28-207.2 & POSTED ON PREMISES. FAILURE TO NOTIFY DEPARTMENT 24 HOU... $800 $0 Jun 2, 2017
Aug 11, 2016 37001208Y RESOLVE CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... $4,000 $0 Jul 14, 2017
Jun 23, 2016 38243686R RESOLVE CLASS - 1 05L10. CAR DOOR OPEN WHEN WHEEL CHAIR LIFT WAS GOING DOWN. $1,000 $0 Sep 23, 2016
Jun 23, 2016 38243688K RESOLVE CLASS - 2 59M05,15I11. $250 $0 Aug 19, 2016
Jun 23, 2016 38243689M RESOLVE CLASS - 2 02L10,05M07,57M07,59M15,70Z02,71L11. $250 $0 Aug 19, 2016
Jun 23, 2016 38243687Z RESOLVE CLASS - 2 15I11,39P16,70P16. $250 $0 Aug 19, 2016
Sep 21, 2015 36023240P RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE WITH CODEPROVISIONS: PERIODIC INSPECTION OF EXTERIOR WAL... $2,000 $0 May 20, 2016
Aug 31, 2015 35133535N RESOLVE CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BLDG.WEST ELEVATION EXP1 SPALLING & DEBERATING MASONRY.VERTICAL CRACKS ON 3RD FL,TREE GR... $1,000 $0 Oct 16, 2015
May 12, 2014 36019200Z RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... $800 $0 Sep 19, 2014
Dec 8, 2008 38198793M RESOLVE CLASS - 2 98U05,100U05. 98U,100U05 - CURRENT 5YR & 2YR GOV TEST 5/03 1/05 $0 $0 Jan 30, 2009
Oct 26, 2007 32055161H RESOLVE Non-Hazardous 50A/.50A-COIL FACE PLATE LEAKING. $180 $0 Dec 21, 2007
Oct 26, 2007 32055155L RESOLVE Non-Hazardous 32A/50A/50B/.50A-DIRTY BOILER ROOM REMOVE DEBRIS.50B-BOILER INSULATIONCOVERING LOOSE,REPAIR OR REPLACE. $180 $0 Dec 21, 2007
Oct 26, 2007 32055156N RESOLVE Non-Hazardous 50A/50B/.50A-COIL FACE PLATE LEAKING.50B-BOILER INSULATION COVERING LOOSE REPAIR OR REPLACE. $180 $0 Dec 21, 2007
Oct 26, 2007 32055157P RESOLVE Non-Hazardous 19A/50A/.50A-BOILER INSULATION COVERING LOOSE REPAIR OR REPLACE. $180 $0 Dec 21, 2007
Oct 26, 2007 32055158R RESOLVE Non-Hazardous 32A/50A/50B/50C/.50A-BOILER INSULATION COVERING LOOSE REPAIR OR REPLACE.50B-SEAL HOLES IN BOILER ROOM WALLS.50C-DIRTY... $180 $0 Dec 21, 2007
Oct 26, 2007 32055159Z RESOLVE Non-Hazardous 32A/50A/50B/50C/.50A-ELECTRICAL CONTROLS UNCOVERED.50B-INTERNAL INSPECTION REVEALS LARGE AMT OF SCALE BUILD UP.50C-BO... $180 $0 Dec 21, 2007
Oct 26, 2007 32055160X RESOLVE Non-Hazardous 50A/50B/.50A-COIL FACE PLATE LEAKING.50B-BOILER INSULATION COVERING LOOSE,REPAIR OR REPLACE. $180 $0 Dec 21, 2007
Oct 26, 2007 32055162J RESOLVE Non-Hazardous 18B/50A/.50A-SAFETY VALVE DISCHARGE NOT PIPE DOWN TO SAFE LOCATION.50B-BLOW DOWN VALVES MUST BE REVERSE TO ALLOW SLOW... $180 $0 Dec 21, 2007
Nov 15, 2006 34548042N RESOLVE Non-Hazardous ALTERED BLDG OCCUPIED W/O A VALID C OF O. TEMPORARY C OF O # 200654416T006 HAS EXP ON 12/21/05. REMEDY:OBTAIN VALID C... $180 $0 Jan 5, 2007
Apr 11, 2006 34515583P RESOLVE Non-Hazardous ALTERED BLDG. OCCUPIED W/O A VALID C OF O DEPT. OF BLDG. RECORDS INDICATE T.C.O. #200654415T006 EXPIRED ON 12/21/05. ... $350 $0 May 26, 2006
Oct 11, 2005 34416819Z RESOLVE Hazardous FAILURE TO PROVIDE SIDE WALK SHED ON THE WEST ELEVATION, SOUTH/WEST CORNERS FACADE UNSAFE CONDITION NO PROTECTION FOR... $2,000 $0 Jul 21, 2006
Jul 19, 2005 34481508M RESOLVE Hazardous WORK WITHOUT PERMIT-DEMOLITION OF CHIMNEY UPON INSP.DEMOLITION OF CHIMNEY APPROX 100FT IN HEIGHT.BRING DEMOLISHED DOB... $800 $0 Apr 7, 2006
Jul 19, 2005 34481507K RESOLVE Non-Hazardous NO DOT PERMIT POSTED FOR ROADWAY CLOSING.UPON INSP. 2 LANES OF ROADWAYCLOSED FRONT OF DEMOLITION OF CHIMNEY 15'FT APR... $400 $0 Jul 21, 2006
Jul 19, 2005 34481506Z RESOLVE Non-Hazardous NO DOT PERMIT POSTED FOR-SIDEWALK CLOSING -FULL SIDEWALK CLOSING -UPONINSP.SIDEWALK IS CLOSED TO PEDESTRIANS FOR APRO... $400 $0 Jul 21, 2006
Jul 19, 2005 34481509Y RESOLVE Non-Hazardous NO DOT PERMIT POSTED.FOR MANLIFT IN STREET/ROADWAY UPON INSPECTION EQUIPMENT IN STREET MAN LIFT BOOM IN STREET NO DOT... $200 $0 Jul 21, 2006
May 13, 2005 38152886H RESOLVE Non-Hazardous 15L10/16N07/13Q07/66Z09 15-REPAIR 16-PROVIDE BY- PASS KEY FOR BASEMENTSERVICE 13-PROVIDE LIGHT GUARD 66-REMOVE WATER ... $0 $0 Jul 1, 2005
Mar 29, 2005 34418084X RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR FACADE. SOUTH ELEVATION FACADE SHOWS EXTENSIVE CRACKS, BULGING SPALLING AND OPEN JOINTS ... $800 $0 May 20, 2005
Jun 22, 2004 34433535L RESOLVE Non-Hazardous ALTERED BUILDING OCCUPIED WITHOUT A VALID C. OF O. ALT.#200654416.T.C.O. EXPIRED 08/20/03.REMEDY:OBTAIN A VALID C. OF O. $350 $0 Aug 6, 2004
Jun 25, 1997 38061040K RESOLVE Non-Hazardous 15330#43Y57O57Z 3RD FLOOR DOOR DON'T CLOSE FULL ADJUST 30 PATCH ALL HOLE IN SHAFTWAY $100 $0 Aug 22, 1997
Jun 25, 1997 38061041M RESOLVE Non-Hazardous 35I50Y57O35X HANDLE TO MOTOR DAMAGE $100 $0 Aug 22, 1997
Mar 26, 1997 38058223X RESOLVE Non-Hazardous 18I,12L,57O,75T, $1,000 $0 May 23, 1997
Mar 18, 1993 34079396L RESOLVE Non-Hazardous DIAGRAM INADEQUATE AT FRONT ELEVATOR & REAR ELEVATOR FLOOR NYMBER SIGNS MISSING IN REAR STAIRCASES STAIR ID SIGNS MIS... $800 $0 Jul 8, 1993
May 20, 1992 34073047X RESOLVE Non-Hazardous ELEVATOR LANDING SIGN MISSING, REAR ELEVATOR. FLOOR NUMBERS SIGNS MISSING IN STAIRCASES(REAR) STAIR & ELEVATOR I.D. S... $0 $0 Jul 10, 1992
May 20, 1992 34073046Y RESOLVE Non-Hazardous FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYINGTO THE INSTALLION OF REQUIRED FIRE PROTECTION S... $500 $0 Jul 10, 1992