Maintenance code violations
1105-1109 Franklin Avenue, Bronx • Block 02608 • Lot 0019
189 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Feb 16, 2022 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2A, 2nd S... | 2A | Feb 22, 2022 |
| Feb 16, 2022 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | — | Feb 22, 2022 |
| Feb 16, 2022 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, ... | 2A | Feb 15, 2022 |
| Feb 16, 2022 | C | VIOLATION CLOSED | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2n... | 2A | Feb 15, 2022 |
| Feb 14, 2022 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5D, 5th S... | 5D | Feb 20, 2022 |
| Feb 14, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WINDOW FRAME IN ... | 5D | Mar 21, 2022 |
| Feb 14, 2022 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5D, 5th STOR... | 5D | Feb 13, 2022 |
| Feb 14, 2022 | C | VIOLATION DISMISSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | — | Feb 20, 2022 |
| Feb 14, 2022 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, ... | 1B | Feb 12, 2022 |
| Feb 14, 2022 | C | VIOLATION DISMISSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | — | Feb 20, 2022 |
| Jun 1, 2021 | C | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CASCADING WATER LEAK AT NORTH ... | 5C | Jun 7, 2021 |
| Jun 1, 2021 | C | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CASCADING WATER LEAK AT NORTH ... | 5C | Jun 7, 2021 |
| Jun 1, 2021 | C | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CASCADING WATER LEAK AT NORTH ... | 5C | Jun 7, 2021 |
| Jan 10, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK INSTALLED AT DOOR. IN THE ENTRANCE LOCATED AT... | 2B | Feb 14, 2019 |
| Jan 10, 2019 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STOR... | 2B | Feb 14, 2019 |
| Jan 10, 2019 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 2B | Feb 14, 2019 |
| Jan 10, 2019 | B | VIOLATION DISMISSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1s... | 2B | Feb 14, 2019 |
| Jan 10, 2019 | B | VIOLATION DISMISSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY,... | 2B | Feb 14, 2019 |
| Jan 10, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL. IN THE 1st ROOM FROM NOR... | 2B | Feb 14, 2019 |
| Nov 15, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BA... | 5A | Dec 20, 2017 |
| Nov 15, 2017 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 5A | Nov 21, 2017 |
| Nov 15, 2017 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT ENTRANCE DOOR AT 1st ROOM FROM NORTH AT WEST, 5th STORY, APARTMENT | 5A | Feb 18, 2018 |
| Nov 15, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE APARTMENT ENTRANCE DOOR , 5th STORY, APARTMENT | 5A | Dec 20, 2017 |
| Nov 15, 2017 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE AT ENTIRE APARTMENT, 5th STORY, APARTMENT | 5A | Dec 20, 2017 |
| Nov 15, 2017 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY,... | 5A | Dec 20, 2017 |
| Nov 15, 2017 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 5A | Nov 21, 2017 |
| Oct 20, 2014 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN AC... | — | Nov 17, 2014 |
| Nov 13, 2013 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE 3rd... | 4B | Feb 16, 2014 |
| Nov 13, 2013 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND NORTH ... | 4B | Feb 16, 2014 |
| Nov 13, 2013 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL IN THE ... | 4B | Feb 16, 2014 |
| Nov 13, 2013 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE ... | 4B | Feb 16, 2014 |
| Nov 13, 2013 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATH... | 4B | Feb 16, 2014 |
| Nov 8, 2013 | A | VIOLATION CLOSED | SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME... | — | Feb 11, 2014 |
| Sep 18, 2012 | A | VIOLATION CLOSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... ADHERED AROUND NORTH WI... | 4C | Dec 22, 2012 |
| Sep 18, 2012 | A | VIOLATION CLOSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... ADHERED AT NORTH WALL I... | 4C | Dec 22, 2012 |
| Sep 18, 2012 | A | VIOLATION CLOSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... ADHERED AROUND WINDOW I... | 4C | Dec 22, 2012 |
| Sep 18, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FLOOR TILES IN THE BATHROOM LO... | 4C | Oct 23, 2012 |
| Sep 18, 2012 | A | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE BATHTUB OR REGLAZE IN THE BATHROOM LOCATED AT APT 4C, 4th ST... | 4C | Dec 22, 2012 |
| Sep 18, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING I... | 4C | Oct 23, 2012 |
| Sep 18, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC LIGHT FIXTURE AT CEILING IN THE 4th ROOM FR... | 4C | Oct 23, 2012 |
| Jul 19, 2012 | B | VIOLATION CLOSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOC... | 4B | Aug 23, 2012 |
| Jul 19, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE BOTTOM SASH WINDOW IN THE 2nd ROOM F... | 2D | Aug 23, 2012 |
| Jul 19, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT BOTTOM SASH WINDOW IN THE 3rd ROO... | 2D | Aug 23, 2012 |
| Jul 19, 2012 | B | VIOLATION CLOSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT L... | 2D | Aug 23, 2012 |
| Jul 19, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE EAST WALL CABINET DOORS IN THE KITCHEN LOCATED AT APT 2D, 2nd STOR... | 2D | Aug 23, 2012 |
| Jul 19, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PILOT LIGHT AT BURNERS IN THE KITCHEN LOCATED AT APT... | 2D | Aug 23, 2012 |
| Jul 19, 2012 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1s... | 1D | Aug 23, 2012 |
| Jul 19, 2012 | B | VIOLATION CLOSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOC... | 1D | Aug 23, 2012 |
| Jul 19, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN TH... | 2B | Aug 23, 2012 |
| Jul 19, 2012 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT SOUTH WALL IN THE 2nd ... | 2B | Oct 22, 2012 |