ECB violations
784-786 Prospect Avenue, Bronx • Block 02688 • Lot 0048
21 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 5, 2026 | 39179312P | ACTIVE | CLASS - 1 | UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER FOR SUMMONS 39135062R., COMPLY WITH COMMISSIONER'S ORDER | $2,500 | $2,500 | Oct 23, 2026 |
| Dec 30, 2025 | 35718787N | ACTIVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. DOB FTC-VIO #111025PI20201TC, DOB FTC-CONTROL #348386, DATED 11/10/2... | $2,500 | $2,500 | Aug 14, 2026 |
| Sep 22, 2025 | 35719034N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.I OBSERVED CRACKED AND DISLODGE ORNAMETAL STONEROCK ON THE BUIL... | $1,250 | $1,250 | Dec 5, 2025 |
| Jan 9, 2025 | 39135063Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - 2ND EGRESS FOR A & B LINE APTS ... | $1,250 | $1,250 | Mar 21, 2025 |
| Jan 9, 2025 | 39135062R | ACTIVE | CLASS - 1 | W/O A PERMIT. NOTED: AT CELLAR - WATER & WASTE LINES INSTALLED FOR WASHER. GAS LINE INSTALLED FOR A DRYER., OBTAIN PE... | $2,500 | $2,500 | Sep 9, 2025 |
| Oct 26, 2021 | 39050062Y | ACTIVE | CLASS - 2 | CLASS 2 VIOLATION ISSUED,/ IN CAR PHONE NOT WORKING, REPAIR,/ HOIST ROPES WORN,REPLACE CABLE,/ MOTOR ROOM LIGHT NOT W... | $625 | $625 | May 13, 2022 |
| Mar 19, 2020 | 39020065M | ACTIVE | CLASS - 2 | CLASS 2,= NO LIGHT IN MOTOR ROOM,/ NO ACCESS TO PIT AREA,/ IN CAR PHONE NOT WORKING,/ CAT 1 YEAR TAG EXP,/ BRAKE TAG ... | $625 | $625 | Dec 18, 2020 |
| May 9, 2019 | 38269663J | ACTIVE | CLASS - 2 | 25M07,26D06,67X10,53B12,52U07,57BB11,40O02,60B10;(25)PROVIDE FIRE SIGNAGE AT ALL FLS.(26)PROPERTLY SECURE HINGES ON C... | $1,563 | $1,563 | Nov 8, 2019 |
| Jul 13, 2016 | 38244232R | RESOLVE | CLASS - 2 | 02B07 2WAY OUTSIDE COMMUNICATION NOT WORKING. | $250 | $0 | Sep 2, 2016 |
| Apr 21, 2015 | 38235048M | RESOLVE | CLASS - 2 | 02X10,15I11,19M07,24X10,61T07,67X10,70O02. 19M07-PROVIDE BOTTOM SAFETYRETAINERS (FIRE GIBBS); 24X10-REPAIR HALL PI (P... | $500 | $0 | Jun 26, 2015 |
| Feb 15, 2011 | 34889738R | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED PLANS AT JOB SITE AT TIME OF INSPECTION:STRUCTURAL REPAIRS: NEW STEEL BEAMS/COLUMNS ERECT... | $250 | $0 | Jul 29, 2011 |
| Feb 15, 2011 | 34889741H | RESOLVE | CLASS - 2 | WORK W/O A PERMIT: EXPIRED PERMIT. STRUCTURAL REPAIRS, NEW STEEL BEAMS/COLUMNS, CONCRETE FOOTING, JOIST REPLACEMENT T... | $400 | $0 | Aug 8, 2011 |
| Mar 4, 2010 | 38209146R | RESOLVE | CLASS - 1 | 76N10.29Q7.60Q7 CU 76N10 PLANK SWITCH BY PASSED REPAIR AND CALL 212 566-5455 FOR CEASE USED LIFT 39Q7 LIGHT GUARD | $1,000 | $0 | Apr 30, 2010 |
| Mar 3, 2009 | 38201120M | RESOLVE | CLASS - 2 | 17H07.70O02.40P16.17H07 HOISTWAY DOOR GIBS ARE WORN ON ALL FLS PROVIDE40P16 PROVIDE ACCESS TO MOTER RM SO THAT A FULL... | $500 | $0 | Dec 4, 2009 |
| Jun 29, 2004 | 38147475R | RESOLVE | Non-Hazardous | 52B14,66Z09,66O02.52-SHORTEN GOVERNON ROPE.66-REMOVE WATER IN PIT.66-CLEAN PIT. | $2,500 | $0 | Aug 20, 2004 |
| Dec 23, 2003 | 38143548K | RESOLVE | Non-Hazardous | 15M7,11M7,16M7,3E1,12X10,12Q3,41G11,86BB5,60T15M84D6,64X10,66O02. 11- MISSING NUMBER TAG FOR 5TH FLR 16-REPLACE MISSI... | $2,500 | $0 | Feb 6, 2004 |
| Feb 19, 2002 | 38121425N | RESOLVE | Non-Hazardous | 75405/73U16/09H12/57O02/55L11/03O02/40#11/05L01. 73 CITY ID# TAGS. 03 CAR TOP. 40 CHECK FOR AND REPAIR, REMOVE KNOCK,... | $2,500 | $0 | Jun 27, 2003 |
| Sep 5, 1997 | 34149459K | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECT IS: DECORATIVE STONE AROUND FIRE ESCAPES IS BULGING, CRACKED AND SPALLING THROUGHOUT BUILD... | $800 | $0 | Oct 24, 1997 |
| Aug 19, 1997 | 38062692K | RESOLVE | Non-Hazardous | 73#9. NO MEANS OF ACCESS TO BUILDING. | $1,000 | $0 | Nov 28, 1997 |
| Apr 17, 1992 | 38023759Y | RESOLVE | Non-Hazardous | 73, RESTORE ELEV. TO SERVICE SO A PROPER INSP. CAN BE MADE. | $1,000 | $0 | Jun 19, 1992 |
| May 29, 1991 | 38005477R | RESOLVE | Non-Hazardous | 73X; 73.RESTORE ELEVATOR SERVICE SO PROPER INSPECTION CAN BE MADE BY THIS DEPT. | $1,000 | $0 | Sep 27, 1991 |