ECB violations
872 Home Street, Bronx • Block 02692 • Lot 0035
31 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 5, 2022 | 39504653J | RESOLVE | CLASS - 2 | OBSERVED A JOB FENCE IN PLACE SECURING THE CONSTRUCTION SITE, UPON REVIEW IN DOB NOW AND BUILDING INFORMATION SYSTEM ... | $0 | $0 | Sep 30, 2022 |
| Aug 5, 2022 | 39504652H | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED INADEQUATE HOUSEKEEPING AT 4 FL. / PENTHOUSE LEVEL, MAKESHIFT PLATFORM, CONSTRUCTION D... | $0 | $0 | Sep 30, 2022 |
| Sep 23, 2021 | 35591336Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SEC REQUIREMENTS ATOI ONACTIVE 4STY TOPPEDOFF NB UNDER PERMIT220632876,... | $625 | $0 | Jan 21, 2022 |
| Sep 23, 2021 | 35591332L | RESOLVE | CLASS - 1 | EXPIRED WORK PERMIT-WORK W/O PERMIT ATOI ON ACTIVE 4STY TOPPEDOFF NB UNDER PERMIT220632876,IT WAS OBSERVED ONGOING CO... | $1,250 | $0 | Jan 21, 2022 |
| Sep 23, 2021 | 35591334P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ONSITE DOCS-CJOIST MANUFACTURERS SPEC ATOION ACTIVE 4STYNB JOBSITE UNDER PERMIT220632876,... | $625 | $0 | Jan 21, 2022 |
| Sep 23, 2021 | 35591338M | RESOLVE | CLASS - 1 | CONST SUPER FAILED TO PERFORM DUTIES PER CODE ATOI ON ACTIVE 4STYNB JOBSITE UNDER PERMIT220632876,IT WAS OBSERVED MUL... | $10,000 | $0 | Jan 21, 2022 |
| Sep 23, 2021 | 35591335R | RESOLVE | CLASS - 1 | WORK DOESNT CONFORM TO PLANS-SSP ATOI ON ACTIVE 4STY TOPPEDOFF NB UNDER PERMIT220632876,IT WAS OBSERVED SWS@EXP1&ADJ ... | $2,500 | $0 | Jan 21, 2022 |
| Sep 23, 2021 | 35591337K | RESOLVE | CLASS - 1 | WORK DOESNT CONFORM TO APPROVED PLANS-SWS&PIPESCF ATOI ON ACTIVE 4STYNB JOBSITE UNDER PERMIT220632876,I OBSERVED PIPE... | $625 | $0 | Jan 21, 2022 |
| Sep 23, 2021 | 35591333N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAYS ONSITE DOCS-DOB APPROVED PLANS ATOI ON ACTIVE JOBSITE 4STY TOPPEDOFF UNDER NB PERMIT2206... | $2,500 | $0 | Jan 21, 2022 |
| Jun 7, 2021 | 35574229Z | RESOLVE | CLASS - 1 | BC33091-FAILURE TO PROVIDE PROPERTY PROTECTION.AT TIME OF INSPECTION ACTIVE JOB SITE CS AND CP WITH 16 WORKERS O SITE... | $625 | $0 | Oct 15, 2021 |
| Jun 7, 2021 | 35574225L | RESOLVE | CLASS - 1 | FAILURE TO COMMUNICATE REQUIRED INFORMATION TO WORKERS DURING PRE-SHIFT SAFETY MEETING.INADEQUATE.ACTIVE JOB SITE 16 ... | $625 | $0 | Oct 15, 2021 |
| Jun 7, 2021 | 35574230X | RESOLVE | CLASS - 2 | CONSTRUCTION SUPERINTENDENT FAILURE TO DO DUTIES PER CODE.AT TIME OF INSPECTION ACTIVE JOB SITE 16 WORKERS 5 SUMMONS ... | $2,500 | $0 | Aug 20, 2021 |
| Jun 7, 2021 | 35574226N | RESOLVE | CLASS - 1 | FIALURE TO PROVIDED SWS WHERE REQUIRED.AT TIME OF INSPECTION ACTIVE JOB SITE 16 MANSONRY WORKERS AT SITE WITH CMU OPE... | $2,400 | $0 | Oct 15, 2021 |
| Jun 7, 2021 | 35574227P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/INSTITUTE SAFETY MEASURES GUARDRAILS.AT TIME OF INSPECTION ACTIVE JOB SITE CS AND CP ON SITE 16 W... | $2,500 | $0 | Aug 20, 2021 |
| Jun 7, 2021 | 35574228R | RESOLVE | CLASS - 1 | FAILUR TO MAINTAIN/INSTITUTE SAFETY MEASURES HAND RAILS.AT TIME OF INSPECTION ACTIVE JOB SITE 16 WORKERS O SITE WITH ... | $625 | $0 | Oct 15, 2021 |
| Nov 9, 2020 | 35540026N | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ONSITE-EXPIRED PERMIT.NOTED:AT THE TIME OF MY INSPECTION OF PROPOSED 4 STORY NEW BUI... | $1,250 | $0 | Jan 29, 2021 |
| Sep 14, 2020 | 35521560J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39024036L ISSUED ON 06/16/20 & TO FILE A CERT OF CORREC... | $1,250 | $0 | Mar 12, 2021 |
| Sep 14, 2020 | 35520441M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39024034H ISSUED ON 06/16/20 AND TO FI... | $1,250 | $0 | Aug 27, 2021 |
| Jun 16, 2020 | 39024034H | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT TIME OF INSP. NB #220632876, AS P... | $25,000 | $0 | Mar 12, 2021 |
| Jun 16, 2020 | 39024035J | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT. (EXPIRED) AT TIME OF INSP. PER FDNY SITE OPEN WITH WORKER WORKING & OPERATING CONSTRUCTION MAC... | $2,500 | $0 | Mar 12, 2021 |
| Jun 16, 2020 | 39024036L | RESOLVE | CLASS - 1 | FAILURE TO PROMPTLY NOTIFY THE DEPARTMENT OF AN ACCIDENT OR DAMAGE TO ADJOINING PROPERTY AT CONSTRUCTION/DEMOLITION S... | $5,000 | $0 | Mar 12, 2021 |
| Oct 29, 2019 | 35457089N | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMENDMENTS.AT TIME OF INSPECTION I OBSERVED ... | $620 | $0 | Dec 20, 2019 |
| Oct 29, 2019 | 35457088L | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE PROTECTION AT SIDE OF EXCAVATION.AT TIME OF INSPECTION I OBSERVED AN CONSTRUCTION SITE WITH EXCAVA... | $5,000 | $0 | Jan 15, 2021 |
| Oct 29, 2019 | 35457087J | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS.AT TIME OF INSPECTION I OBSERVED AN ... | $10,000 | $0 | Jan 15, 2021 |
| Oct 29, 2019 | 35457090K | RESOLVE | CLASS - 1 | BC3309.6;BC1814.3/FAILURE TO MONITOR STRUCTURES FOR MOVEMENTS IN ALL DIRECTIONS DURING EXCAVATION RELATED ACITVITY TH... | $2,500 | $0 | Jan 15, 2021 |
| Oct 29, 2019 | 35457091M | RESOLVE | CLASS - 1 | BC3304.4.4/FAILURE TO PROVIDE 3'6 GUARDRAILS SYSTEM OR SOLID ENCLOSUREAROUND OPEN AND ACCESIBLE SIDES OF EXCAVATION.A... | $2,500 | $0 | Jan 15, 2021 |
| Oct 29, 2019 | 35457092Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33 "SITE SAFETY PLANS". AT TIME OF INSPECTION I ... | $1,250 | $0 | Jan 15, 2021 |
| Oct 2, 2019 | 35452899M | RESOLVE | CLASS - 1 | FAILURE TO MAINYAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY CHAPTER 33 NO SITE SAFETY PLAN AT TIME OF INSPECTIOB I OBSE... | $1,250 | $0 | Dec 20, 2019 |
| Oct 2, 2019 | 35452898K | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DEPARTMENT PRIOR TO THE COMMENEMENT OF EATRHWORK AT TIME OF INSPECTION I OBSERVED THE CONTRACTO... | $0 | $0 | Dec 20, 2019 |
| Aug 23, 2019 | 35452691N | RESOLVE | CLASS - 2 | PERMIT EXPIRED-FAILED TO RENEW FENCE PERMIT. AT TIME OF INSPECTION,IT WAS OBSERVED THAT A CONSTRUCTION FENCE WAS INST... | $0 | $0 | Oct 18, 2019 |
| Aug 23, 2019 | 35452690L | RESOLVE | CLASS - 2 | JOBSITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. ATTIME OF INSPECTION IT WAS OBSERVED THAT A CONST... | $0 | $0 | Oct 18, 2019 |