ECB violations

728-734 Kelly Street, Bronx • Block 02708 • Lot 0025

73 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 17, 2026 39177450Y ACTIVE CLASS - 2 ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED IN MAIN ELECTRICAL ROOM NEW ELECTRICAL PANELS INSTALLED ALSO THE LAUNDRY R... $1,250 $0 Sep 25, 2026
Feb 17, 2026 39177488J ACTIVE CLASS - 2 OBSERVED ON THE ROOF STANDING WATER DUE TO IMPROPER DRAINAGE. AT EXTERIOR STREET LEVEL STORM DRAIN IS CRUSHED. IN THE... $1,250 $1,250 Sep 25, 2026
Feb 17, 2026 39177489L ACTIVE CLASS - 1 OBSERVED AT EXTERIOR STREET LEVEL SPRINKLER SIGNAGE INDICATES SPRINKLERS SYSTEM THROUGHOUT THE BUILDING WHEN THERE IS... $2,500 $2,500 Sep 25, 2026
Feb 17, 2026 39177487H RESOLVE CLASS - 1 OBSERVED ON SEVENTH FLOOR AND IN BASEMENT, PVC PIPING IS INSTALLED ON WASTE LINES. IN BASEMENT SPRINKLER HEADS ARE OB... $2,500 $0 Sep 25, 2026
Aug 12, 2025 35718435J RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALL(S) OR APPURTENANCES. NOTE:-AT THE TIME OF INSPECTION OBSERVED(1) AT ROOF L... $0 $0 Oct 17, 2025
Feb 3, 2025 39137219P RESOLVE CLASS - 2 EXIT DOOR NOT SELF-CLOSING. OBVSERED NON SELF CLOSING DOORS THROUGHOUT BUILDING., REPAIR/REPLACE DOOR $625 $0 Jul 25, 2025
Feb 3, 2025 39137218N RESOLVE CLASS - 1 UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED UNSAFE STORAGE UNDERNEATH STAIRCASE (MINI FRIDGES) LEA... $2,500 $0 Apr 18, 2025
Feb 3, 2025 39137198P RESOLVE CLASS - 2 FOUND OIL FIRED FEDERAL BOILERS ACTIVE WITH DEFECTS. CONDENSATE RETURN TANK DEFECTIVE LEAKING WATER. CORRECT ALL VIOL... $625 $0 Aug 1, 2025
Feb 3, 2025 39137217L RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... $2,500 $0 Apr 18, 2025
Feb 8, 2023 39512859P RESOLVE CLASS - 2 NOTE: OBSERVED SIDEWALK SHED AT EXP1,4; HAVE MISSING SCREW CAPS CREATE SHARP EDGE(3307.6.5.6) CONDITION, CUT HAZARD F... $2,400 $0 Apr 21, 2023
Nov 28, 2022 35541089P RESOLVE CLASS - 2 FAILURE TO SECURE/SUPPORT RACEWAYS/CABLE ASSEMBLIES/BOXES/CABINETS/FITTINGS.I OBSERVED IN VENT CONTROL RM LOCATED UND... $0 $0 Feb 3, 2023
Nov 28, 2022 35541088N RESOLVE CLASS - 1 FAILURE TO PROTECT TEMP WIRING FROM IMPROPER CONDUCT.I OBSERVED IN ROOFTOP VENT CONTROL RM LOCATED UNDER ELEVATOR MOT... $1,600 $0 Feb 3, 2023
Nov 1, 2022 39073136J RESOLVE CLASS - 2 AT CELLAR LEVEL, GAS METER ROOM, WALLS DO NOT MEET ,CONSTRUCTION TECHNICAL SPECIFICATIONS (FIRE RESISTANT WALL) WALLS... $0 $0 Jan 13, 2023
Nov 1, 2022 39073127H RESOLVE CLASS - 2 AS PER TWO 60 HP, FEDERAL BOILERS; COMBUSTION AIR FAN NOT OPERATING-NO BELT GUARDS ON TWO OIL PUMPS AT OIL STATION-HO... $0 $0 Dec 16, 2022
Nov 1, 2022 39073135H RESOLVE CLASS - 2 AT 3RD FLOOR, SMOKE DOOR NEAR ROOM # 310, AT CELLAR LEVEL, CAFETERIA EXIT DOOR AND BOILER ROOM,2ND EXIT DOOR TO PARKI... $0 $0 Jan 13, 2023
Dec 28, 2020 39034046Y RESOLVE CLASS - 2 SAFETY VALVES LEAKING-GUARD MISSING FOR GAGE GLASS-SMOKE ALARM NOT SOUNDING OFF WHEN TESTED; CORRECT ALL VIOLATING CO... $0 $0 Mar 19, 2021
Mar 10, 2020 39019344R ACTIVE CLASS - 1 UPON INSPECTION DEVICE WAS FOUND OUT OF SERVICE . RESTORED TO SERVICE IMMEDIATELY AND CONTACT NYCDOB FOR A COMPLETE I... $1,250 $0 Nov 20, 2020
Mar 10, 2020 39019343P RESOLVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... $1,250 $0 Nov 20, 2020
Mar 10, 2020 39019345Z RESOLVE CLASS - 1 UPON INSPECTION DEVICE WAS FOUND OUT OF SERVICE . RESTORE TO SERVICE IMMEDIATELY AND CONTACT NYCDOB FOR A COMPLETE IN... $1,250 $0 Nov 20, 2020
Feb 11, 2020 37017544J RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #38269665N ISSUED ON 05-09-2019,AND TO FILE... $625 $0 Nov 20, 2020
Jan 14, 2020 39015728H RESOLVE CLASS - 2 I OBSERVED THE VIOLATING CONDITIONS LISTED IN ECB# 35442252M ISSUED ON 07/08/2019 UNCORRECTED., FILE A CERTIFICATE OF... $625 $0 Sep 11, 2020
Jan 14, 2020 39015730R RESOLVE CLASS - 2 I OBSERVED THE VIOLATING CONDITIONS CITED IN ECB #35442253Y ISSUED ON 07/08/2019 STILL IN EFFECT, FILE A CERTIFICATE ... $625 $0 Sep 11, 2020
Jan 14, 2020 39015729J RESOLVE CLASS - 2 I OBSERVED IN THE COMMERCIAL KITCHEN THE USE OF DUPLEX RECEPTACLES NOT OF THE GFCI TYPE NOR GFCI PROTECTED AS REQUIRE... $0 $0 Feb 26, 2021
Jan 14, 2020 39015731Z RESOLVE CLASS - 1 I OBSERVED IN THE ELECTRICAL EQUIPMENT ROOM A 200 AMP SERVICE DISCONNECT WITH THE NEUTRAL NOT BONDED AS REQUIRED., PR... $0 $0 Feb 26, 2021
Aug 28, 2019 38271037P RESOLVE CLASS - 1 97.X.10=CLASS 1 RESTORE TO SERVICE ENTIRE DEVICE INOPERATIVE $312 $0 Oct 18, 2019
Jul 8, 2019 35442251K RESOLVE CLASS - 1 UNSAFE, UNSUITABLE, ELECTRICAL EQUIPEMENT/WIRING INUSE. I OBSEVRED ON THE ROOF THE USE OF ARMORED CABLE TO POWER UP A... $1,600 $0 Aug 30, 2019
Jul 8, 2019 35442252M RESOLVE CLASS - 2 FAILURE TO PROVIDE GROUYND FAULT CIRCUIT INTERRUPTER AS REQUIRED. I OBSERVED IN THE COMMERCIAL KITCHEN THROUGHOUT 110... $1,200 $0 Aug 30, 2019
Jul 8, 2019 35434215N RESOLVE CLASS - 1 FGC408.2/MISCELLANEOUS VIOLATION:FUTURE CONNECTIONS EXIST ON GAS PIPING.OBSERVED IN LAUNDRY ROOM A FUTURE CONNECTION ... $0 $0 Dec 13, 2019
Jul 8, 2019 35442253Y RESOLVE CLASS - 1 FAILURE TO INSTALL GROUDING ELECTRICAL CONDUCTOR IN ACCORDANCE WITH SECTION. I OBSERVED IN THE CELLAR A 200 AMP SERVI... $4,800 $0 Aug 30, 2019
Jul 8, 2019 35434214L RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLAINT MANNER.OBSERVED IN THE CELLAR AT THE FIRE SPRINKLER CONTROL VALVES R... $1,250 $0 Oct 2, 2020
May 9, 2019 38269665N RESOLVE CLASS - 2 16H11,17M07,80B09,77Q03,42T11,56Y13,59B07,52U07,68M07,72B07;(16)WORN DOOR RELEASE ROLLERS(17)MISSING HOISTWAY DOOR GI... $625 $0 Jul 5, 2019
Feb 26, 2019 38267917L RESOLVE CLASS - 2 71X10,39O02,21M07,29M07,53M07,56O02,56Y13,44O02,70O02. 71X10-REPAIR PIT LIGHT; 39O02 CLEAN TOP OF CAR; 21M07-PROVIDE ... $310 $0 Apr 19, 2019
Jan 4, 2019 38267096N RESOLVE CLASS - 1 97-X-10=UPON INSPECTION DEVICE WAS FOUND OUT OF SERVICE.RESTORE TO SERVICE IMMEDIATELY AND CONTACT NYC DOB FOR COMPLE... $312 $0 Mar 1, 2019
Dec 18, 2018 35391612J RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35331818K ISSUED ON 5/25/18 AND TO FIL... $1,250 $0 Feb 19, 2019
Oct 26, 2018 35389283P RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/ VIOLATION #35331818K ISSUED ON 05/25/18 AND TO FILE ... $1,250 $0 Dec 21, 2018
Sep 12, 2018 35386936J RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35331818K ISSUED ON 05-25-18 & TO FILE A C OF C PURSUAN... $1,250 $0 Nov 16, 2018
Aug 24, 2018 32097196N RESOLVE CLASS - 2 B254,50. SPILL SWITCH MISSING. CORRECT VIOLATING CONDITIONS AND SUBMIT CERTIFICATES OF CORRECTION. $625 $0 Oct 19, 2018
Aug 1, 2018 32097424X RESOLVE CLASS - 2 32A,50A-AS PER CLASS 2 (B254) 28-301.1 FAILURE TO MAINTAIN. 32A)EXPOSED ELECTRICAL WIRES AT FEEDER BOX. 50A)"U" RATED... $0 $0 Sep 21, 2018
Jul 19, 2018 35387461J RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35331818K ISSUED ON 05-25-18 & TO FILE A C OF C PURSUAN... $1,250 $0 Oct 5, 2018
Jun 8, 2018 35335590L RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT FIRST FLOOR CLASS ROOM,TWO EXIT SIGN IN SIDE THAT ROOM IS NO... $250 $0 Aug 31, 2018
May 25, 2018 35331818K RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT CELLAR LEVEL TANK ROOM FLOOR BEING HELD UP BY STEEL ADJUSTAB... $1,250 $0 Jul 20, 2018
May 25, 2018 35334107H RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDINGS IN CODE-COMPLIANT MANNER.OBSERVED ON 05/25/2018 AT ABOVE ADDRESS ON CELLAR LEVEL GAS ME... $625 $0 Jul 20, 2018
May 25, 2018 35331817Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC1008.1;27-371.AT R... $0 $0 Jul 20, 2018
May 25, 2018 35331816R RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO FIRE STOPPINGPER 712.3;27-345.NOTED:HOLES IN WALL AND CEILIN... $1,250 $0 Jul 20, 2018
May 16, 2018 35331832R RESOLVE CLASS - 1 NON CURRENT CARRYING ELECTRICAL CONDUCTIVE MATERIAL IS NOT GROUNDED. OBSERVED AT EXTERIOR PERIMETER. A FULLY OPERATIO... $4,800 $0 Jul 20, 2018
Oct 5, 2017 35297193N RESOLVE CLASS - 1 SEC. 411.1 RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMENT. OBSERVED ON 10-5-17 AT ABOVE ADDRESS RESIDENTIAL GAS FL... $1,600 $0 Apr 13, 2018
Jun 20, 2017 37003035Y RESOLVE CLASS - 2 FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000002676 HASBEEN INSPECTED,TESTED,AND DISINFECTED,AND THAT ... $1,000 $0 Dec 11, 2017
May 23, 2017 35267482M RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:NO FIRE STOPPINGPER BC712.3;37-345.NOTED:OBSERVED ON ELLAR LEVE... $1,250 $0 Aug 4, 2017
May 23, 2017 35267388X RESOLVE CLASS - 1 FGC411.1/RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMENT.OBSERVED ON 5/23/17 AT ABOVE ADDRESS IN CELLAR RESIDENTIAL... $1,600 $0 Jul 21, 2017
Dec 7, 2016 38251540Y RESOLVE CLASS - 2 1L10,5J1,10H11,17H11,67L10,68M7,56Y2,56713. 1L10-EMERGENCY STOP SWITCH DEFECTIVE REPAIR; 5J1-CAR DOOR MISALIGNED ADJU... $0 $0 Feb 3, 2017