Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 13, 2020 37018246X RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... $1,250 $0 Oct 23, 2020
Nov 30, 2019 35418872N RESOLVE CLASS - 2 FAILED TO NOTOFY DEPARTMENT PRIOR TO INSTALLATION OR REMOVAL OF SUSPEDNED SCAFFOLD NOTE AT THE TIM EOF MY INSPECTION ... $0 $0 Nov 27, 2020
Nov 30, 2019 35418873P RESOLVE CLASS - 1 SIDEWALK SHED WHERE REQUIRED NOTE AT THE TIME OF MY INSPECTION 08 ACTIEV JOBSITE I OBSERVED WORKED ON THE(6 FLOOR) (0... $0 $0 Nov 27, 2020
Nov 30, 2019 35418871L RESOLVE CLASS - 1 3303.10.1=TENANT PROTETCION PLAN NOTE AT THE TIME OF MY INSPECTION OF A ACTIVE JOBSITE I OBSERVED IN TEH UIDLING OCCU... $0 $0 Nov 27, 2020
Nov 30, 2019 35418870J RESOLVE CLASS - 1 WORK CONTRARY TO AFTER HOUR VARIANCE NOTE AT THE TIME OF MY INSPECTIPON ON A ACTIEV JOBSITE I OBSERVED WORKER ON 6 FL... $0 $0 Nov 27, 2020
Sep 11, 2019 38271440P RESOLVE CLASS - 1 (C.U.C-59E10)53U7,26D6,59B7,99B7,40O2,56Y13,42D6,2X10,42M7,70O2-CEASE USE CONT. RECURRING CONDITION AGGRAVATED 1 PER ... $3,125 $0 Nov 1, 2019
May 28, 2019 39003406R RESOLVE CLASS - 2 FOUND LOW WATER CUT OFF INOPERATIVE, SHALL BE REPLACED DUE TO CORROSION AT SWITCH. SAFETY RELIEF VALVE MISSING TEST L... $312 $0 Aug 30, 2019
Nov 30, 2018 38266803Z RESOLVE CLASS - 2 70O02,80M07,67X10,100I10,56Y010. 70O02- RMDY: CLEAN DIRTY PIT; 80M07-RMDY PROVIDE RUNBY SIGNAGE; 67X10-RMDY: REPAIR C... $0 $0 Jan 18, 2019
Aug 22, 2016 38243786Y RESOLVE CLASS - 1 05A10,35D06,56413,57U15,59U15,61M97,68M97,71L10. (05A10) CAB DOOR RESTRICTOR IS BEEN TAMPERED WITH.(REPAIR) $0 $0 Oct 7, 2016
Aug 22, 2016 38243787X RESOLVE CLASS - 1 05A10 CAB DOOR RESTRICTOR IS BEEN TAMPERED WITH (REPAIR) $1,000 $0 Dec 16, 2016
Feb 22, 2016 38241256H RESOLVE CLASS - 2 98-M-07:PROVIDE MISSING 5 YEAR TEST TAG. $500 $0 Jun 17, 2016
Jan 6, 2016 38240424N RESOLVE CLASS - 2 98BB05,4010,07N10,70O02,52U15,59U15. 98-PERFORM AND FILE 5 YEAR TEST; 40-MOTOR ROOM STAIRS DAMAGED; 07-ZONE RESTRICTO... $500 $0 Mar 4, 2016
Apr 21, 2015 38235842J RESOLVE CLASS - 1 CU 08V01, CU20M07,02L10,98M05,56Q03,42E10. CU08-FLOOR STOPS EXCESSIVELY OUT OF LEVEL MUST ADJUST IMMEDIATELY; CU20-BA... $1,000 $0 Jun 5, 2015
Feb 5, 2014 38230049L RESOLVE CLASS - 2 15M07,17H11,20K11,21Q03,19M07,29Q03,35Q03,52M07,60G03,61T07,67M07,69M770O02,71X10,71Q03,72M07,76M07,77B07,98BB05. 17H... $500 $0 Apr 4, 2014
Jan 27, 2014 35078125L RESOLVE CLASS - 3 WORK W/O A PERMIT. WORK NOTED AT APT 5-J CORNER INSTALLED A PARTITION WALL W/ENTRANCE DOOR AT LIVING ROOM TO MAKE AN ... $0 $0 Aug 5, 2014
May 28, 2013 38226120N RESOLVE CLASS - 2 21Q3, 1D11,3U7,15U7,12Q3,41T15,29Q3,35Q3,6H10,20U7,27T15,29Q3,68U7,60Q3,98BB5,99BB5,61T15,81T15,71U7,72U7,77K11,97O2,... $0 $0 Jul 19, 2013
Feb 13, 2012 38220851J RESOLVE CLASS - 2 07X10,15M07,20M11,21Q03,29Q03,35Q03,39O02,40O02,41T07,43Q03,52M07,56Y13,60Q03,61M07,67M07,68B07,69M07,70O02,71X10,71Q... $0 $0 Mar 30, 2012
Sep 17, 2010 36014999X RESOLVE CLASS - 2 FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESC... $400 $0 Feb 18, 2011
May 26, 2010 34836417R ACTIVE CLASS - 2 FOLLOWING THE RECEIPT OF A PERMIT TO ERECT A SIDEWALK SHED, THE PERMITHOLDER SHALL POST A READILY VISIBLE SIGN ON THE... $800 $0 Dec 3, 2010
Feb 18, 2010 34837130Y RESOLVE CLASS - 2 FAILURE TO PROVIDE SAFETY MEASURES OR SIDEWALK SHED WHERE REQUIRED ACCORDING TO THE CYCLE #6 TECHNICAL REPORT (TR-6) ... $2,400 $0 Jun 4, 2010
Feb 5, 2010 36012641M RESOLVE CLASS - 2 FAIL TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED... $800 $0 Oct 29, 2010
Nov 27, 2009 36010406N RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... $0 $0 Feb 19, 2010
Nov 27, 2009 36010402X RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... $400 $0 Feb 19, 2010
Oct 23, 2009 36010017J RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXT... $800 $0 Feb 5, 2010
Feb 6, 2009 34735307N RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTED: EXTERIOR FRONT FACADE (LEFT SIDE OF BLDG) HAS DIAGONAL CR... $250 $0 Apr 3, 2009
Jan 30, 2009 36008010Y RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... $800 $0 Jan 4, 2010
Oct 17, 2008 38192200K RESOLVE CLASS - 2 08V10.32H10.17H11.73P06.08V10 ADJUST FL STOPS ON ALL FLS 32H10 CAR GUIDE SHOES ARE WORN 17H11 HOISTWAY DOOR GIBS ARE ... $500 $0 Dec 19, 2008
Apr 2, 2007 38165194J RESOLVE Non-Hazardous 27L10,15M7,5L10,8V1,16L10,20I10,5L10,59L10,55Y13,20M7. 27/L- CAR DOOR HANGERS & CONNECTION NEED REPAIR. 5/L-CAR DOOR ... $350 $0 Jun 1, 2007
Mar 10, 1998 38071361K RESOLVE Non-Hazardous 25Q3,31Q3,11X11,8V1,18Q3,35P17,30O2,46H10,57O2. 31-TOP OF CAR. 11-CAR TOP & UNDER CAR. $350 $0 May 11, 1998
Jul 8, 1996 38057127L RESOLVE Non-Hazardous 75U,50Y,73X,57O,74O,. (74) TOP OF CAR. $200 $0 Apr 11, 1997
May 26, 1993 38034251R ACTIVE Non-Hazardous 02L,14I,10I,17Q,57O. $5,000 $0 Jul 9, 1993