1767 Weeks Avenue, Bronx
Bronx • Block 02796 • Lot 0042 • Zip: 10457
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Times Square 39 min 5 walking, 34 riding
- Grand Central 41 min 5 walking, 36 riding
- Penn Station 42 min 5 walking, 37 riding
- Union Square 45 min 5 walking, 40 riding
- Fulton Street 51 min 5 walking, 46 riding
- Downtown Brooklyn 56 min 5 walking, 51 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Bus
Citi Bike
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
HPD violation Jul 21, 2026
Class A
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND WINDOW FRAME IN THE ...
-
HPD violation Jul 21, 2026
Class B
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ...
-
HPD violation Jul 21, 2026
Class B
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH SHOWER WALL I...
-
HPD violation Jul 21, 2026
Class B
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GASKET SEAL TO REFRIGERATOR DOOR IN THE KITCHEN LOC...
-
HPD violation Jul 17, 2026
Class B
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A...
-
HPD violation Jul 17, 2026
Class A
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 2...
2024
-
CLASS - 2
FOUND ON FEDERAL BOILER MODEL FST 60 BTU 2520000 FOUND THERE WAS TUBES LEAKING ON REAR OF BOILER NEED TO FIX AND SUBM...
2023
-
DOB violation Oct 12, 2023
C-CONSTRUCTION OTHER OPTIONAL
EMERGENCY WORK (IMMEDIATELY RETAIN A LICENSED ENGINEER TO PREPARE EMERGENCY.SLOPE.STABILIZATION.PLANS FOR THE COLLAPS...
-
CLASS - 2
W/O A PERMIT. NOTED: AT EXPOSURE 3 - CMU BLOCK WALL ERECTED APPRX 5' AT LEFT SIDE OF LOT., OBTAIN ALL PERMITS
-
CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: AT TIME OF INSPECTION - 1. REAR FIRE ESCAPE AT LEFT OF EXPOSU...
-
CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: 1. AT EXPOSURE 2: EXCESSIVE GARBAGE ACCUMULATED APPRX 8...
-
DOB violation Sep 29, 2023
C-CONSTRUCTION OTHER OPTIONAL
APPRX. FIFTY FEET OF TEN FEET HIGH RETAINING WALL COLLAPSED AT EXPOSURE#3 BACK YARD. THE RETAINING WALL FALLEN DIRECT...
2022
-
CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35635696Y ISSUED 12/13/21 AND FILE CERTIF...
-
CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39050556Y ISSUED ON 11/4/2021 AND TO F...
-
DOB violation Feb 2, 2022
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2013
-
Alteration Type II
REPLACE OIL BURNER WITH GAS/OIL BURNER ON NYC BOILER NO. MD 15851-01 AND INSTALL NEW GAS SERVICE, METER AND PIPING.
2012
2011
-
Alteration Type II
GAS REPIPIPING OF BUILDING AND REPLACEMENT OF METER BARS. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
2010
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records