ECB violations
124 East 177 Street, Bronx • Block 02805 • Lot 0045
25 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 17, 2026 | 39196644X | ACTIVE | CLASS - 1 | CLASS 1 ITEM: ELEVATOR REMAINS OUT OF SERVICE FOR AN EXTENDED PERIOD AND HAS NOT BEEN RESTORED TO OPERATION. PREVIOUS... | $1,250 | $1,250 | Oct 2, 2026 |
| Jun 17, 2026 | 39192933Y | ACTIVE | CLASS - 1 | RTS CLASS 1: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-9... | $1,250 | $1,250 | Sep 4, 2026 |
| Apr 22, 2026 | 35729800M | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES.-NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #1 NORTH (1) ... | $5,000 | $5,000 | Feb 26, 2027 |
| Aug 5, 2025 | 39156018M | ACTIVE | CLASS - 2 | CLASS 2 ITEMS: 1) HOIST WAY DOOR IN THE BASEMENT SLAMMING WHEN CLOSING, ADJUST DOOR CHECK. 2) EXCESSIVE SIDE TO SIDE ... | $625 | $0 | Oct 17, 2025 |
| Jul 21, 2025 | 39154414P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER NOTED: AT TIME OF INSPECTION OBSERVED, BULKHEAD DOOR LEADING ... | $1,250 | $1,250 | Jan 16, 2026 |
| Jul 21, 2025 | 39154415R | ACTIVE | CLASS - 1 | UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER FOR VIOLATION #39136585K ISSUED ON 01/27/2025 FTM FOR GAS ... | $2,500 | $0 | Oct 3, 2025 |
| Jan 27, 2025 | 39136582P | ACTIVE | CLASS - 2 | WORK WITHOUT A PERMIT. NOTED AT BASEMENT LEVEL SOUTH-EAST GAS METER ROOM, INSTALLED WATER SUPPLY & WASTE LINES FOR SL... | $1,250 | $1,250 | Mar 23, 2026 |
| Jan 27, 2025 | 39136581N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS P... | $625 | $24 | Sep 29, 2025 |
| Jan 27, 2025 | 39136583R | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. NOTED BULKHEAD ROOF ACCESS DOOR IS RACKED ON FRAME & EQUIPPED ... | $625 | $0 | Apr 4, 2025 |
| Jan 27, 2025 | 39136584Z | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED AT BASEMENT LEVEL, GAS METER ROOMS HAVE ILLEGAL STORAGE.... | $625 | $0 | Sep 19, 2025 |
| Jan 27, 2025 | 39136585K | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED AT BASEMENT LEVEL SW LAUNDRY ROOM, TWO GAS-POWERED COMME... | $1,250 | $0 | Apr 4, 2025 |
| Jan 27, 2025 | 39136580L | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) & APPURTENANCES. NOTED AT EXP#1 EAST END, FACADE HAS SEVERAL VERTICAL CRACKS FRO... | $1,250 | $1,250 | Mar 23, 2026 |
| Jun 20, 2024 | 35685378Y | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING AND APPURTENANCES. NOTE: OBSERVED AT EXPOSURE 1(NORTH ELEVATION) MASONRY CRACKS... | $1,250 | $0 | Jan 13, 2025 |
| Mar 20, 2024 | 35682336M | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.OBSERVED AT EXPOSURE#3(NORTH ELEVATION)BROKEN WINDOW G... | $2,500 | $2,500 | May 31, 2024 |
| Mar 20, 2024 | 39109387X | ACTIVE | CLASS - 1 | CLASS 2: CLEAN HOIST MACHINE., SEAL HOIST MACHINE., CLEAN OIL SPILL ON THE FLOOR AROUND THE HOIST MACHINE., PROVIDE C... | $1,250 | $0 | May 31, 2024 |
| Oct 9, 2023 | 35581849P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING @ APT 2C MAIN BATHROOM ABOVE THE TUB 2FT X 4FT OPENING @ THE CEILING APT 3C WATER LEAK C... | $1,250 | $0 | Dec 15, 2023 |
| Sep 18, 2023 | 39095097N | RESOLVE | CLASS - 3 | EVIDENCES OF WATER LEAK IN THE BATHROOM IN APARTMENT #2C. OBSERVED WATER STAINS AND DAMAGED CEILING AND WALLS SURFACE... | $0 | $0 | Dec 1, 2023 |
| Jun 17, 2022 | 39064400P | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED DLM IMPROPERLY INSTALLED ON THIS DEVICE, NO FIREMAN SERVICE PRESENT IN CONTROLLER, INSTALL F... | $1,250 | $0 | Sep 30, 2022 |
| Oct 17, 2020 | 39030560Z | RESOLVE | CLASS - 1 | CLASS 1 NO DOOR LOCK MONITORING INSTALL IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. R... | $1,280 | $0 | Jan 15, 2021 |
| Oct 3, 2012 | 38223712N | RESOLVE | CLASS - 2 | 12Q03,10B07,32H11,39O02,52M07,60Q03,61T07,67M07,70O02. 10-B-07-PROVIDEA 2ND GIBB TO CAR DOOR AS REQUIRED Y CODE 20-M-... | $0 | $0 | Nov 30, 2012 |
| Jun 1, 2012 | 34937317M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS AND/OR APPURTENANCES. NOTE: THE INTERIOR SHEEETROCK FLRING IS SPALLING W/PEELING PAINT... | $500 | $0 | Jul 20, 2012 |
| Feb 6, 2009 | 32065602N | RESOLVE | CLASS - 3 | VIOLATING CONDITIONS 15,32A,34,38,50A 50-FRESH AIR FAN DEFECTIVE AND NOT WORK 50A-BACKFLOW PREVENTOR BLOW OFF NOT PIP... | $500 | $0 | Apr 3, 2009 |
| Oct 14, 2008 | 38191993P | RESOLVE | CLASS - 2 | 32H10.39Y02.53H11.56Y13.56Y13.56O02.60B06.41D06.32H10 TOP & BOTTOM CAR GUIDE SHOE ARE WORN 39Y02 TOP OF HAS OIL CLEAN... | $500 | $0 | Dec 5, 2008 |
| May 15, 2007 | 38166953X | RESOLVE | Non-Hazardous | 5L10,16L10,83L10,27H11,31H11.5/L-CAR DOOR DOESN'T OPEN ALL THE WAY.16/L-DOOR CHECKS 6TH,4TH,2ND FLS.83/L CAR STOPS TO... | $0 | -$180 | Jul 6, 2007 |
| Mar 4, 1998 | 38071181N | RESOLVE | Non-Hazardous | 14M7,75U5,35D6,35O2,21X11,20L11,28H11,50Y11,53X11. | $180 | $0 | Apr 24, 1998 |