ECB violations
1515 Selwyn Avenue, Bronx • Block 02819 • Lot 0051
113 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Dec 26, 2018 | 32097574L | ACTIVE | CLASS - 2 | 50=AS PER CLASS 2(B254)FAILURE TO MAINTAIN FOUND ONE BOILER A ROCKMILLS OR FEDERAL FIRED A MMG 42P BURNER ON GS TO HO... | $655 | $0 | Feb 15, 2019 |
| Dec 3, 2018 | 35392025J | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35297978N ISSUED ON 12/27/17 AND TO F... | $1,250 | $1,250 | Jan 18, 2019 |
| Nov 30, 2018 | 35396421J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/ VIOLATION #35347216J ISSUED ON 9/ 5 /18 AND TO F... | $1,250 | $1,250 | Jan 18, 2019 |
| Nov 30, 2018 | 35396422L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/ VIOLATION #35311375M ISSUED ON 1/14 /18 AND TO F... | $2,500 | $2,500 | Jan 18, 2019 |
| Oct 31, 2018 | 32097884R | ACTIVE | CLASS - 2 | 16,42,151,34A,34B,(50A-50F)-50A)BOLTS AND DOGS MISSING ON BOILER DOORS. 50B)VENT LIMINATOR MISSING ON GAS REGULATOR. ... | $3,125 | $3,125 | Jan 18, 2019 |
| Oct 16, 2018 | 32098007J | ACTIVE | CLASS - 2 | B254,11A,34B,501,503,50C,50D.PER CLASS 2 (B254) 28-301.1 FAILURE TO MAINTAIN 50A-DOGLEGS MISSING AT FRONT BOILER ACCE... | $625 | $625 | Mar 22, 2019 |
| Oct 15, 2018 | 35390182Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/ VIOLATION #35360283X ISSUED ON 8/29/18 AND TO F... | $1,250 | $1,250 | Mar 22, 2019 |
| Oct 15, 2018 | 35390181M | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/ VIOLATION #35311345M ISSUED ON 01/04/18 AND TO ... | $1,250 | $1,250 | Mar 22, 2019 |
| Oct 15, 2018 | 35390183X | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35347214X ISSUED ON 9/5/18 AND TO FILE ... | $1,250 | $1,250 | Mar 22, 2019 |
| Oct 15, 2018 | 35390184H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/ VIOLATION #35347216J ISSUED ON 9/05/18 AND TO FI... | $1,250 | $1,250 | Mar 22, 2019 |
| Sep 26, 2018 | 35389637N | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35297978N DM ISSUED ON 12/27/17 AND TO F... | $1,250 | $0 | Sep 27, 2019 |
| Sep 11, 2018 | 32097425H | ACTIVE | CLASS - 1 | (CEASE USE)50,15-B154(50)FOUND FEDERAL BOILER MODEL #FST-90 LEAKING (51)HAZARDOUS CONDITION.DO NOT OPERATE BOILER UNT... | $1,250 | $0 | Jan 25, 2019 |
| Sep 6, 2018 | 32097756M | ACTIVE | CLASS - 2 | 50E,11A.50F,50A.50G,50B,50C,50D:AS PER CLASS 2 (B254) 28.301.1 FAILURE TO MAINTAIN .11A:SURFACE BLOWDOWN VALVE & PIPI... | $625 | $315 | Nov 2, 2018 |
| Sep 5, 2018 | 35347216J | ACTIVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR DOB RECORDS. AT TIME OF INSPECTION OBSEVED ONE ... | $6,000 | $6,000 | Aug 16, 2019 |
| Sep 5, 2018 | 35347214X | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER, AT TIME OF INSPEC TION NOTED: EGRESS OBSTRUCTED BY FURNITURE BUILD... | $3,125 | $3,125 | Feb 8, 2019 |
| Aug 29, 2018 | 35360283X | ACTIVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED PASSAGEWAY NOTED:AT PASSAGEWAY FROM EXP #2 LEADING FROM REAR AND SIDE YARD.THERE A GA... | $6,250 | $6,250 | Oct 19, 2018 |
| Aug 21, 2018 | 35341196Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIO# 35311375M ISSUED ON 1/4/18 & TO FILE A C OF C... | $5,000 | $5,000 | Oct 5, 2018 |
| Aug 21, 2018 | 35341197X | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIO# 35297978N ISSUED ON 12/27/17 & TO FILE A C OF... | $12,500 | $12,500 | Oct 5, 2018 |
| Aug 20, 2018 | 35359609Z | ACTIVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE. STREET LEV... | $8,000 | $8,000 | Oct 5, 2018 |
| Aug 20, 2018 | 35359608R | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. STREET LEVEL APT#2: BRANCH CIRCUIT WIRING,RECEPTACLE OUTLET SWITCH."NOT ON FILE" PLESE ... | $4,000 | $4,000 | Oct 5, 2018 |
| Aug 20, 2018 | 35359610X | ACTIVE | CLASS - 2 | FAILURE TO INSTALL GROUND-FRONT CIRCUIT INTERRUPTER(GFCI)PROTECTION AS REQUIRED. STREET LEVEL APT#2 BATHROOM: NO GFCI... | $10,000 | $10,000 | Oct 5, 2018 |
| Aug 16, 2018 | 35344062M | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION, I OBSERVED DEFECTIVE BATHROOM FLOOR... | $625 | $312 | Oct 5, 2018 |
| Jul 11, 2018 | 35340743J | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35297978N ISSUED ON 12/27/17 AND TO FI... | $12,500 | $12,500 | Aug 31, 2018 |
| Jul 11, 2018 | 35340742H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35311375M ISSUED ON 01/04/18 AND TO FI... | $3,125 | $3,125 | Aug 31, 2018 |
| Jun 26, 2018 | 35315630Z | RESOLVE | CLASS - 1 | AN UNLAWFUL ACT. FAILURE TO COMPLY W/ AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT & CERTIFY SUMMONS# 35313234H. ... | $6,250 | $6,250 | Aug 17, 2018 |
| May 17, 2018 | 35338595Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO #35311375M ISSUED ON 01/04/18 & TO FILE A CERT OF CORRE... | $3,125 | $3,125 | Jul 6, 2018 |
| May 16, 2018 | 35338274N | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/ VIOLATION #35297978N ISSUED ON 12/27/17 AND TO ... | $6,250 | $6,250 | Jul 6, 2018 |
| Apr 26, 2018 | 35313234H | ACTIVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIMET,APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE GROUND FLOOR ... | $1,630 | $0 | Jun 15, 2018 |
| Apr 6, 2018 | 35325041J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER ORDER CONTAINED IN SUMMONS/VIOLATION #35311375M ISSUED ON 01/04/18 AND TO FIL... | $1,280 | $0 | Jun 1, 2018 |
| Feb 15, 2018 | 35282856N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35311376Y ISSUED ON 01/04/18 & TO FILE A C OF C PURSUAN... | $2,000 | $0 | Apr 6, 2018 |
| Feb 15, 2018 | 35282855L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35311375M ISSUED ON 01/04/18 & TO FILE A C OF C PURSUAN... | $830 | $0 | Apr 6, 2018 |
| Jan 4, 2018 | 35311376Y | ACTIVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY WASHING MACHINE BLOCKING EXIT PASSAGEWAY TO STREET CONSTRUCTION MATER... | $6,000 | $0 | Mar 16, 2018 |
| Jan 4, 2018 | 35311375M | ACTIVE | CLASS - 1 | OCCUPANCY CONTRARY TO CERTIFICATE OF OCCUPANCY OR DEPARTMENT OF BUILDING RECORDS BASEMENT BEING USED AS (2) CLASS A S... | $2,400 | $2,400 | Aug 16, 2019 |
| Dec 27, 2017 | 35297978N | RESOLVE | CLASS - 1 | WORK W/OUT A PERMIT. OBSERVED @ CELLAR FULL KITCHEN W/ GAS STOVE 2 PCS BATHROOM & TOUGHING W/ RESIDENTIAL SINK W/ KIT... | $800 | $0 | Sep 27, 2019 |
| Aug 14, 2017 | 32091515Y | ACTIVE | CLASS - 2 | B254,15,34A,50,50A,50B. 50-MISS SIGHT GLASS ON REAR OF BOILER; 50A-BOILER BURNER NOT GOING INTO HIGH FLAME; 50B-NEED ... | $2,500 | $0 | Oct 6, 2017 |
| Jul 25, 2016 | 35197643N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES.DEFECTES NOTED:1AIR CONDITIONER UNITS @APARTMENT WINDOWS THROUGHOUT T... | $500 | $0 | Sep 16, 2016 |
| Jun 15, 2015 | 32074747Z | ACTIVE | CLASS - 1 | B154,32,39,51,24A,28A,B,C. B154-51-HAZARDOUS CONDITION 80 PARTS PER MILLION SHOWING ON MY CARBON MONOXIDE DETECTOR IN... | $5,000 | $0 | Dec 4, 2015 |
| May 7, 2014 | 35078861J | RESOLVE | CLASS - 3 | WORK W/O A PERMIT FLOOR TO CEILING PARTITION ERECTED INSIDE APT#ST1-GROUND LEVEL.ADDITIONAL BEDROOM ADDED TO A ONE BE... | $200 | $0 | Nov 14, 2014 |
| May 3, 2011 | 32070624K | ACTIVE | CLASS - 1 | B154/40/28B/51/54A/50A/50B/50C/50D/50E/50F/50A-BOILER BURNER HEAVY SMOKE AND SOOT HAZ/50B-FLUE PIPE NOT SEALED TO CHI... | $5,000 | $0 | Jun 17, 2011 |
| Dec 8, 2010 | 34872997K | ACTIVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. - BENT CROSS BRACE - USING TEMP LIGHTING ON PART OF SHED (MAIN ENTRA... | $2,400 | $0 | Mar 25, 2011 |
| Oct 13, 2010 | 34872719K | RESOLVE | CLASS - 1 | LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQUIREMENTS. STOP WORK ORDER ISSUED FOR FOLLOWING: NO C... | $1,600 | $0 | Feb 25, 2011 |
| Oct 13, 2010 | 34872718Z | RESOLVE | CLASS - 2 | FAILED TO OBTAIN A TEMPORARY CONSTRUCTION PERMIT PRIOR TO INSTALLATION/USE OF SIDEWALK SHED. NO PERMIT FOR SHED. REME... | $250 | $0 | Feb 25, 2011 |
| Aug 31, 2010 | 34858408M | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. - MISSING VANDAL PROOF FIXTURES. - BRIDGE IS NOT SEALED (NO NETTING ... | $10,000 | $0 | Oct 29, 2010 |
| Aug 9, 2010 | 34858168M | ACTIVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. - MISSING VANDAL PROOF - NETTING IN COURTYARD AREA NOT ATTACHED TO U... | $10,000 | $0 | Mar 4, 2011 |
| Aug 9, 2010 | 34858167K | RESOLVE | CLASS - 2 | FAILED TO OBTAIN A TEMPORARY CONSTRUCTION PERMIT PRIOR TO INSTALLATIONUSE OF SIDEWALK SHED. - NO PERMIT FOR SHED. REM... | $2,500 | $0 | Mar 4, 2011 |
| Jul 23, 2010 | 34851411L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR OF BUILDING. DEFECT: THROUGHOUT PARAPET,THERE ARE CRACKS,MORTAR IS MISSING FROM BRICK WO... | $2,500 | -$2,500 | Sep 17, 2010 |
| Jan 5, 2010 | 34817543Y | RESOLVE | CLASS - 2 | BC3307.6.5 & 27-1021 FAILURE TO PROVIDE MAINTAIN PROPER SIDEWALK ILLUMINATION NOTED AT NORTH ELEVATION SIDE WALK ILLU... | $4,000 | $0 | Mar 5, 2010 |
| Feb 11, 2009 | 34735478H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE/POST SIGN(S) AT JOB SITE PURSUANT TO SUBSECTION. NOPERMIT POSTED FOR SIDEWALK SHED. REM: POST PERM... | $800 | $0 | Nov 19, 2009 |
| Feb 11, 2009 | 34735479J | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. 1- DOES NOT HAVE ADEQUATE LIGHTING- 6 BULBS MISSING. 20 CROSS BEAMS ... | $2,400 | $0 | Nov 19, 2009 |
| Feb 3, 2009 | 34735403N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG CODE COMPLIANT MANNER USE OF PROHIBITED DOOR HARDWARE PER BC 100.1.8; 27-371J NOTED AT BOTH ... | $500 | $0 | Nov 19, 2009 |