ECB violations
1546 Selwyn Avenue, Bronx • Block 02820 • Lot 0016
64 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 5, 2026 | 39172360H | ACTIVE | CLASS - 2 | REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. MISALINGED CAB MIRROR. INOPERATIVE CAB LIGHT. MISALINGED CA... | $625 | $625 | Oct 5, 2026 |
| Dec 1, 2025 | 35718067P | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION I OBSERVED EXP #1 WEST-CRACKE... | $5,000 | $5,000 | Aug 18, 2026 |
| Dec 1, 2025 | 35718068R | ACTIVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.-NOTE: AT TIME OF INSPECTION, I OBSERVED MULTIPLE OBJECTS ON FIRE ESC... | $1,250 | $1,250 | Aug 18, 2026 |
| Aug 3, 2024 | 35684010L | RESOLVE | CLASS - 1 | UNLAWFUL ACT: FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER'S: OWNER/RESPONDENT FAILED TO COMPLY TO SUMMONS #35... | $0 | $0 | May 6, 2025 |
| Aug 3, 2024 | 35684012P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS FACADE AND APPURTENANCES: OBSERVED DEFECTED CONDITION AT THE VIEW EXPOSUR... | $1,250 | $0 | Dec 6, 2024 |
| Apr 8, 2024 | 35682541L | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: OBSERVED AT EXPOSURE 1(WEST ELE.) MASONARY CRAC... | $2,500 | $0 | Dec 3, 2024 |
| Apr 8, 2024 | 35682542N | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE: OBSERVED AT EXPOSURE 1(WEST ELE.) AND EXPOSURE 3(EAST) SEVERAL... | $0 | $0 | Dec 3, 2024 |
| Aug 20, 2022 | 39068497Z | RESOLVE | CLASS - 1 | RTS, UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT-OF-SERVICE AS PER 1RCNY 11-02. REMEDY; RESTORE TO SERVICE, IMMEDI... | $0 | $0 | Feb 8, 2023 |
| Sep 25, 2020 | 39029295Z | RESOLVE | CLASS - 2 | HOIST MACHINE BRAKE MAINTENANCE TAG EXPIRED PROVIDE, MAINTENANCE LOG UPDATE MISSING PROVIDE. COMMUNICATION DEFECTIVE ... | $0 | -$312 | Jan 22, 2021 |
| Oct 17, 2018 | 38265940K | ACTIVE | CLASS - 2 | 32H11,10H11,67L10,70O02. 32H11-CAR BOTOTM SHOES ARE WORN REPLACE; 10 H11-CAR DOOR GIBS ARE WORN, REPLACE; 67L10-PHONE... | $625 | $0 | Mar 29, 2019 |
| May 17, 2018 | 35338594M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO #35348734X ISSUED ON 02/16/18 & TO FILE A CERT OF CORRE... | $0 | $0 | Jul 6, 2018 |
| Apr 6, 2018 | 35325044P | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35248734X ISSUED ON 2-16-18 & TO FILE A C OF C PURSUANT... | $0 | $0 | Jun 15, 2018 |
| Feb 16, 2018 | 35248734X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF IN SPECTION I OBSERVED MULTIPLE VERTICAL AND HORIZO... | $0 | $0 | Jun 8, 2018 |
| Jul 3, 2017 | 35227535K | RESOLVE | CLASS - 2 | ELECTRICAL WORK W/OUT A PERMIT. TO INSTALL FAN W/ LIGHT IN KITCHEN LIGHT FIXTURE & OUTLETS THROUGHOUT APT 4C ON THE 4... | $400 | $0 | Aug 18, 2017 |
| Dec 7, 2016 | 35201966R | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. THE ENTIRE BLDG HALLWAYS PLP SUB PANEL: SUB FEEDER,SUB PANEL 125 AMP BRANCH CIRCUIT WIR... | $800 | $0 | Mar 30, 2017 |
| Dec 7, 2016 | 35201965P | RESOLVE | CLASS - 2 | FAILURE TO PROPERLY BOND ELECTRICAL SYSTEMS. BASEMENT SERVICE SWITCHESALL 3-400AMP SERVICE SWITCHES MODEL #1TGB4325 G... | $750 | $0 | Mar 30, 2017 |
| Dec 7, 2016 | 35201964N | RESOLVE | CLASS - 2 | FAILURE TO GROUND ELECTRICAL SYSTEMS BASEMENT SEWER GROUND CONDICTOR: NO WATER MAIN GROUND PROVIDED. PLEASE NOTE THE ... | $1,200 | $0 | Mar 24, 2017 |
| Mar 15, 2016 | 38241374Z | RESOLVE | CLASS - 2 | 99M15 ONE YEAR BRAKE TAG IS MISSING (PROVIDE) | $500 | $0 | May 6, 2016 |
| Apr 20, 2014 | 35090915H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED:APT 5D-WALLS CRACKED W/SECTIONS OF PLASTER BULGED & DISPLACED... | $500 | $0 | Aug 8, 2014 |
| Feb 13, 2013 | 35053976Z | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN NOV #35050304M ISSUED ON 12/6/12. FAILURE TO COMPLY COMMISSIONE... | $0 | $0 | May 30, 2013 |
| Dec 6, 2012 | 35050304M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOTICE OF VIOLATION #34941164M ISSUED ON 3/2/12. NOTE: AT B... | $0 | $0 | Mar 22, 2013 |
| May 15, 2012 | 34970218L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A C/C W/THE DOB FOR NOV #34941163K ISSUED ON 3.2.12 PURSUANT TO ... | $800 | $0 | Jun 29, 2012 |
| May 15, 2012 | 35049606J | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOV #34941164M ISSUED ON 3.2.12. NOTE: BASEMENT ERECTED PAR... | $2,400 | $0 | Jun 29, 2012 |
| Mar 2, 2012 | 34941163K | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C/O. CO #2037 STATES - CELLAR - SUPT'S APT (4) ROOMS, BOILER ROOM, PLAYROOM... | $2,400 | $0 | Apr 27, 2012 |
| Mar 2, 2012 | 34941161R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING BSMNT ROOMD & CORRIDORS FULL OF OLD CABINETS,FRAMES,BOXES TELEVISIONS,HOUSE... | $0 | $0 | Apr 20, 2012 |
| Mar 2, 2012 | 34941162Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.ROOF PARAPET MISSING MORTOR.ROOF METAL CHIMNEY-WALL ANCHORS BROKEN.... | $0 | $0 | Apr 20, 2012 |
| Mar 2, 2012 | 34941164M | RESOLVE | CLASS - 1 | WORK W/O A PERMIT - WORK NOTED: BASEMENT - ERECTED PARTITIONS THRU-OUTLAUNDRY - INSTALLED WATER/WASTE & GAS LINE - GA... | $1,600 | $0 | Apr 30, 2012 |
| Jan 23, 2012 | 38219388Z | RESOLVE | CLASS - 2 | 100I11,15I11,14I11,12Q03,09N10,10M07,20M07,27T15,37P07,40P07,70O02;100-ELEV PHONE DAMAGED & NOT WORKING. | $0 | $0 | Mar 16, 2012 |
| Dec 30, 2011 | 34925194N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. DEFECT NOTED: AT 3RD STORY,APT 3G KITCHEN FLOOR WOOD BEAMS ARE... | $0 | $0 | Mar 16, 2012 |
| Jan 5, 2011 | 38214777J | RESOLVE | CLASS - 2 | 03K10 12Q03 15M07 37O02 37W07 37T07 39O02 40O02 20I11 21Q03 60Q03 64M07 69M07 70O02 77M07. 03K10- REPAIR ROTTED SECTI... | $500 | $0 | Apr 8, 2011 |
| Nov 24, 2010 | 34891309L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMMS ORDER TO FILE A CERT OF CORRECTION W/ THE DOB NOTED RESPONDENT FAILED TO CORRECT THE V... | $800 | $0 | Mar 18, 2011 |
| Nov 24, 2010 | 34891307H | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY WIITH AN ORDER OF THE COMM'S NOTED:RESPONDENT FAILED TO CORRECT THE CONDITIONS CITED ... | $2,400 | $0 | Mar 4, 2011 |
| Nov 24, 2010 | 34891306X | RESOLVE | CLASS - 1 | UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER NOTED:RESPONDENT FAILED TO CORRECT THE CONDITIONS C... | $0 | $0 | Feb 25, 2011 |
| Nov 24, 2010 | 34891310Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED:APPROX 600SF CRACKED, MISSING OR DISPLACED.THIS CONSTITUTES A... | $1,000 | $0 | Mar 4, 2011 |
| Nov 24, 2010 | 34891308J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED:RETAINING WALL,APPROX 10FTLONG X 2FT HIGH FORMING PART OF THE... | $1,000 | $0 | Mar 18, 2011 |
| Sep 22, 2010 | 38212318L | RESOLVE | CLASS - 1 | 97X10,16M16 97X10-ONLY ELEVATOR IN BLDG IS OUT SERVICE THEREBY CREATING CONDITION DANGEROUS TO HUMAN LIFE AS PER 1 RC... | $0 | $0 | Nov 19, 2010 |
| Sep 1, 2010 | 34871043P | RESOLVE | CLASS - 1 | FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: ROCK WALL, AT REAR YARD NORTH, HAS PARTLY COLLAPSED & IS STRUC... | $1,000 | $0 | Mar 18, 2011 |
| Sep 1, 2010 | 34871044R | RESOLVE | CLASS - 1 | WORK W.O A PERMIT. NOTED: APPROX 100LF 7FT HIGH CHAIN LINK FENCE, ANCHORED BY 100 LF 2 TIERED 8" CONCRETE BLOCKS & TO... | $800 | $0 | Jan 14, 2011 |
| Sep 1, 2010 | 34871045Z | RESOLVE | CLASS - 1 | UNLAWFUL ACTS. FAIL TO COMPLY W/COMM ORDER. NOTED: RESPONDENT FAILED TO CORRECT THE CONDITIONS CITED IN THE PRIOR NOV... | $0 | -$800 | Jan 14, 2011 |
| Jul 29, 2010 | 38211968Z | RESOLVE | CLASS - 2 | 08V10,32H10,70O02,12Q03,39O02,40P16. 08V10-ADJUST FLOOR STOPS WERE NEEDED. 32H10-TOP & BOTTOMCAR GUIDE SHOES ARE WORN... | $0 | $0 | Sep 17, 2010 |
| Apr 29, 2010 | 34847952M | RESOLVE | CLASS - 1 | WORK W/OUT A PERMIT.NOTED:REAR YARD,CMU CONCRETE BLOCK RETAINING WALL WAS REMOVED FROM ENTIRE LENGTH OF REAR YARD,APP... | $0 | $0 | Nov 10, 2010 |
| Apr 29, 2010 | 34847953Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED:REAR CMU(CONCRETE BLOCK)RETAINING WALL HAS BEEN REMOVED LEAVI... | $1,000 | $0 | Oct 22, 2010 |
| Aug 13, 2009 | 38205255H | RESOLVE | CLASS - 2 | 08V1020M0720M0714L0715M0705J0198BB0570O0239O0259H1116B01. 08V10 ADJUSTFLR STOPS WERE NEEDED. 20M07 VISION GLASS IS MI... | $0 | $0 | Oct 2, 2009 |
| Dec 22, 2008 | 38199605K | RESOLVE | CLASS - 2 | 14M07,32H10,40O01,08V10. 14M07-CAR MIRROR IS MISSING PROVIDE.32H10-TOP& BOTTOM CAR GUIDE SHOES ARE WORN PROVIDE.40O02... | $250 | $0 | Sep 11, 2009 |
| Oct 2, 2008 | 34696022K | RESOLVE | CLASS - 2 | RESIDENCE ALTERED FOR MORE THAN THE LEGALLY APPROVED # OF FAMILIES.NOTE. IN CELLAR PARTITION CREATED THREE SRO W/HOT ... | $1,200 | $0 | Aug 20, 2009 |
| Oct 2, 2008 | 34696023M | RESOLVE | CLASS - 3 | WORK W/O A PERMIT. WORK NOTED: IN CELLAR PARTITIONS CREATED THREE ROOMMADE OUT OF PLYWOOD AND DOORS W/ KEY LOCK. REME... | $0 | $0 | Nov 21, 2008 |
| Oct 23, 2007 | 38178691N | RESOLVE | Non-Hazardous | 31H10,51H11,52H11,55Y10,55O02,66O02,14M07,15M07. 31H10 TOP AND BOTTOM CAR GUIDE SHOES ARE WORN. | $350 | $0 | Dec 7, 2007 |
| Aug 14, 2007 | 38168311N | RESOLVE | Hazardous | CEASE USE.12X10,11X10,23X10,36D06.12X10-CU-CAR LIGHTING INOPERATIVE NOLIGHT.11X,23X10-IN ELEV CAB.ELEVATOR NOT RESPON... | $800 | $0 | Dec 7, 2007 |
| Feb 28, 2005 | 38151241X | RESOLVE | Non-Hazardous | 20I7/10H11/27H11/66O02/52B14/08V01. 20-PROVIDE VISION GLASS FOR 1,2 FLOORS DOORS.10-REPLACE WORN CAB DOOR GIBBS ON FR... | $0 | $0 | Apr 15, 2005 |
| Jan 21, 2005 | 38150690R | RESOLVE | Non-Hazardous | 85BB05/25D10/36P07/16B10/55F10/38O02/66O02 36-P-07 NO LADDER TO OVERHEAD ROOM 16-B-10 4TH FLOOR DOOR STOPS CAR. | $0 | $0 | Mar 4, 2005 |