ECB violations
1895 Morris Avenue, Bronx • Block 02827 • Lot 0046
38 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 23, 2026 | 39185773Z | ACTIVE | CLASS - 2 | MISSING IN CASE OF FIRE SIGNS (AS PER FDNY) REPLACE OR SECURE HOISTWAY DOOR GIBS WHERE NEEDED (2.11.11.5.7). ADJUST F... | $625 | $625 | Sep 4, 2026 |
| Jan 28, 2026 | 39175240R | ACTIVE | CLASS - 1 | CEASE USE ITEMS: : DOOR ZONE RESTRICTOR INOPERATIVE, CREATING A HAZARDOUS CONDITION PER 1RCNY11-02. REMEDY: RESTORE T... | $1,250 | $1,250 | Aug 21, 2026 |
| Apr 11, 2024 | 37027944H | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $1,250 | Aug 23, 2024 |
| Jun 20, 2023 | 39088739K | ACTIVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED IN APPENDIX K OF THE BUILDING 2014 CODE; REMEDY INSTALL D... | $1,250 | $1,250 | Apr 9, 2024 |
| Aug 8, 2022 | 39067601P | ACTIVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED IN APPENDIX K3 OF 2014 BUILDING CODES; REMEDY: INSTALL DL... | $3,125 | $3,125 | Dec 2, 2022 |
| Oct 7, 2021 | 39049139P | ACTIVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 O... | $3,125 | $3,125 | Aug 19, 2022 |
| Mar 2, 2021 | 39036982X | ACTIVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL... | $1,250 | $1,250 | Dec 3, 2021 |
| Dec 28, 2015 | 38240024Y | ACTIVE | CLASS - 2 | 07L10,18L10,27U15,28H11,30B06,42D06,42Q03,52V15,57V15,67L10,16M07. 07-ZONE RESTRICTOR BYPASSED; 18-BASEMENT SPRING CL... | $500 | $0 | Feb 19, 2016 |
| Oct 3, 2014 | 36019844Y | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $4,000 | $0 | Jan 16, 2015 |
| Jun 24, 2014 | 35066608H | RESOLVE | CLASS - 1 | WORK W/O A PERMIT ON 6/24/14 DURING PHYSICAL INSP I OBSERVED IN THE CELLAR LAUNDRY ROOM 3 LG WASHERS AND DRYERS,WASTE... | $1,600 | $0 | Oct 10, 2014 |
| Jun 24, 2014 | 35066611Z | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY OR DOB RECORDS.DURING PHYSICAL INSP I OBSERVED ONE LAUNDR... | $0 | $0 | Oct 10, 2014 |
| Jun 22, 2014 | 35066610R | ACTIVE | CLASS - 1 | FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED/2 DRYERS OR MORE DURING PHYSICAL INSP I OBSERVED 2... | $1,000 | $0 | Oct 10, 2014 |
| Jun 12, 2014 | 35066609J | ACTIVE | CLASS - 1 | GAS IS BEING SUPPLIED TO BLDG W/O INSP & CERT BY DOB DURING PHYSICAL INSP I OBSERVED 2 LG DRYERS IN USE IN THE CELLAR... | $1,000 | $0 | Oct 10, 2014 |
| Jun 11, 2012 | 36018453M | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/ARTICLE 28.302 OF THE BLDG CODE & DOB'S RULES... | $4,000 | $0 | Nov 16, 2012 |
| Jan 15, 2012 | 36018253H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/CODE PROVISIONS: PERIODIC INSPECTION OF EXTER... | $2,000 | $0 | Jun 1, 2012 |
| Apr 15, 2011 | 36016573H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXT... | $2,000 | $0 | Sep 9, 2011 |
| Mar 1, 2011 | 34892518M | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG WALLS. NOTED: NUMEROUS UNSUPPORTED A/C'S W/BRICKS, STONE, CANS & WOOD ON SILLS OF A... | $500 | $0 | Apr 15, 2011 |
| Jan 21, 2011 | 34897166K | RESOLVE | CLASS - 1 | UNLAWFUL ACT(S) FAILURE TO COMPLY W/AN ORDER OF THE COMM.RESPONDENT FAILED TO CORRECT THE CONDITIONS CITED IN N.O.V.#... | $2,400 | $0 | Apr 1, 2011 |
| Nov 23, 2010 | 34891302Z | RESOLVE | CLASS - 1 | UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.NOTED:RESPONDENT FAILED TO CORRECT THE CONDITIONS C... | $6,000 | $0 | Mar 3, 2011 |
| Sep 23, 2010 | 34877692M | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER NOTED:RESPONDENT FAILED TO CORRECT THE CONDITIONS C... | $2,400 | $0 | Mar 3, 2011 |
| Sep 23, 2010 | 34877691K | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.... | $1,000 | $0 | Mar 3, 2011 |
| Jul 12, 2010 | 36014071Z | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS: PERIODIC INSPECTION OF E... | $2,000 | $0 | Oct 15, 2010 |
| Jun 30, 2010 | 34851163L | RESOLVE | CLASS - 2 | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED NUMBER OF FAMILIES PARTITIONS ERECTE... | $1,200 | $0 | Sep 10, 2010 |
| May 28, 2010 | 34850931K | RESOLVE | CLASS - 1 | WORK W/O A PERMIT: FLR TO CEILING PARTITION ERECTED AT BASEMENT (LAUNDRY AREA) TO CREATE ADDITIONAL SPACE 2 PC BATHRO... | $1,600 | $0 | Oct 15, 2010 |
| Nov 27, 2009 | 36010430N | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXT... | $4,000 | $0 | Mar 5, 2010 |
| Jan 30, 2009 | 36008173Z | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... | $800 | $0 | Sep 18, 2009 |
| May 14, 2007 | 38166951M | RESOLVE | Non-Hazardous | 15M7,14M7,3I9,27H11,31H11,83H11,5I10,83L10.3/I-CAR ENCLOSURE HAS SHARPEDGES(REMOVE).5/L-CAR DOOR DOSN'T OPEN ALL THE ... | $350 | $0 | Sep 14, 2007 |
| Dec 1, 2006 | 38163002R | RESOLVE | Non-Hazardous | 14M07,15M07,21Q03,08V01,40D06,42Q03,05X10.21-3RD FL LOCK COVER MISSING08-BASEMENT FLOOR STOP NOT LEVEL.40-DOOR LOCK M... | $0 | $0 | Jan 19, 2007 |
| Dec 19, 2005 | 38164302N | RESOLVE | Hazardous | 09-I-10/16-X-10/15-M-11/03-I-10/63-B-11/85-M-07/56-X-10/66-O-02. (09-I-10) ELEVATOR FLOOR ROTTED. REPLACE OR REPAIR. ... | $500 | $0 | Apr 28, 2006 |
| Jan 12, 2001 | 34274146M | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT PURSUANT TO RULE R.C.N.Y.32-03B(5),INDICATING CO... | $1,000 | $0 | Mar 16, 2001 |
| Sep 18, 2000 | 34249099Y | RESOLVE | Hazardous | FAILURE TO AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT PURSUANT TO RULE R.C.N.Y.32-03B(5),INDICATING CORRECT... | $2,500 | $0 | Nov 24, 2000 |
| Jul 14, 2000 | 34248432Y | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDIC... | $2,500 | $2,500 | Oct 13, 2000 |
| Jun 5, 2000 | 34248787N | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT. PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDICATING... | $400 | $0 | Sep 8, 2000 |
| May 16, 2000 | 38097929J | RESOLVE | Non-Hazardous | 3,I,4,22,I,12,14,M,7,15,B,1,73,U,16,35,D,6,46,Y,2,8,V,11,62,K,2,57,O,2,30,O,2,73,M,7,25,M,7,3-PATCH DAMAGE AIR VENT T... | $0 | $0 | Jun 23, 2000 |
| Jan 14, 1999 | 32016445H | RESOLVE | Non-Hazardous | 28B 49 28B TUBES LEAKING 49 SEAL AROUND COIL PLATE CORRODED | $180 | $0 | Jul 23, 1999 |
| Jul 31, 1998 | 34170953M | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN <DEFECT IS> DEFECTIVE SAGGING AND COLLAPSING WOOD FLOOR IN HALLWAY AND BEDROOMS IN APT#1G-FIRST F... | $180 | $0 | Sep 28, 1998 |
| May 15, 1997 | 38062520Y | RESOLVE | Non-Hazardous | 14M0735P | $200 | $0 | Mar 27, 1998 |
| Sep 11, 1992 | 38028993P | RESOLVE | Non-Hazardous | 02L,35P,57O. | $0 | $0 | Nov 13, 1992 |