Maintenance code violations
Hawkstone Street, Bronx • Block 02836 • Lot 0012
1,757 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| May 27, 2025 | B | NOV SENT OUT | § 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING , AT 1st FIRE PASSAGE WAY FROM EAST AT SOUTH, 1st STORY | — | Jul 1, 2025 |
| May 27, 2025 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PADLOCKABLE GATE AT 1st FIRE PASSAGE WAY FROM EAST ... | — | Jun 2, 2025 |
| May 27, 2025 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Jun 10, 2025 |
| May 27, 2025 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CHAIN AND PADLOCK AT GATE AT 1st FIRE PASSAGE WAY F... | — | Jun 2, 2025 |
| May 27, 2025 | B | NOV SENT OUT | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Jul 1, 2025 |
| May 27, 2025 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE IN... | — | Jun 2, 2025 |
| May 21, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL ... | 1O | Jun 25, 2025 |
| May 21, 2025 | B | NOV SENT OUT | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BROKEN LIGHT FIXTURE AT CEILING IN THE BATHROOM LOC... | 1O | Jun 25, 2025 |
| May 21, 2025 | B | NOV SENT OUT | § 27-2005 HMC: REFIT BEDROOM DOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 1O, 1st STORY, 1st APARTMENT FROM WEST AT... | 1O | Jun 25, 2025 |
| May 21, 2025 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1O, 1st STORY, ... | 1O | May 21, 2025 |
| May 21, 2025 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | — | May 27, 2025 |
| May 21, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE K... | 1O | Jun 25, 2025 |
| May 21, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CRACKED BROKEN VINYL FLOOR TILES CREATING TRIP HAZA... | 1O | Jun 25, 2025 |
| May 21, 2025 | B | NOV SENT OUT | § 27-2005 HMC: REFIT TOP CABINETS DOORS AT WEST WALL. IN THE KITCHEN LOCATED AT APT 1O, 1st STORY, 1st APARTMENT FRO... | 1O | Jun 25, 2025 |
| May 21, 2025 | B | NOV SENT OUT | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BROKEN ROOM DOOR IN THE 1st ROOM FROM EAST LOCATED ... | 1O | Jun 25, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM... | 5F | Jun 23, 2025 |
| May 19, 2025 | B | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING LESS THAN 30 SQ F... | 5F | Jun 23, 2025 |
| May 19, 2025 | C | VIOLATION CLOSED | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT THE WASH BASIN IN THE BATHROOM LOCATED AT APT... | 5F | May 25, 2025 |
| May 19, 2025 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES AT EAST WALL IN T... | 5F | May 25, 2025 |
| May 19, 2025 | A | NOV SENT OUT | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION METAL RISER IN THE BATHROOM LOCATED AT APT 5F, 5th... | 5F | Aug 22, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE AT THE BATHTU... | 5F | Jun 23, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ... | 5F | Jun 23, 2025 |
| May 19, 2025 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HARDWOOD FLOORS IN THE 1st ROOM FROM... | 5F | May 25, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING AND EAST WALL I... | 5F | Jun 23, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ... | 5F | Jun 23, 2025 |
| May 19, 2025 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCES AT THE LOWER WINDOW SASHES OF WINDO... | 5F | May 25, 2025 |
| May 19, 2025 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HARDWOOD FLOORS IN THE PRIVATE HALLW... | 5F | May 25, 2025 |
| May 19, 2025 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING INSIDE OF THE CLO... | 5F | Jun 14, 2025 |
| May 19, 2025 | A | NOV SENT OUT | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION METAL WINDOW GATE, RISER, AND RADIATOR IN THE 1st ... | 5F | Aug 22, 2025 |
| May 19, 2025 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HARDWOOD FLOORS IN THE 1st ROOM FROM... | 5F | May 25, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 1st ROOM... | 5F | Jun 23, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 1st ROOM... | 5F | Jun 23, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ... | 5F | Jun 23, 2025 |
| May 19, 2025 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCES AT LOWER WINDOW SASHES OF WINDOWS A... | 5F | May 25, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS IN THE... | 5F | Jun 23, 2025 |
| May 19, 2025 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | 5F | Jun 2, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE KITCHEN ... | 5F | Jun 23, 2025 |
| May 19, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ... | 5F | Jun 23, 2025 |
| May 19, 2025 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING IN T... | 5F | May 25, 2025 |
| May 19, 2025 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | — | May 25, 2025 |
| May 19, 2025 | A | NOV SENT OUT | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION METAL RADIATOR AND RISER IN THE 1st ROOM FROM NORT... | 5F | Aug 22, 2025 |
| May 16, 2025 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, ... | 5F | May 15, 2025 |
| May 8, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE PRIVATE HAL... | 2R | Jun 12, 2025 |
| May 8, 2025 | B | NOV SENT OUT | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE OF LOWER WINDOW SASH IN THE 1st ROOM... | 2R | Jun 12, 2025 |
| May 8, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN TH... | 2R | Jun 12, 2025 |
| May 8, 2025 | A | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL ... | 2R | Aug 11, 2025 |
| May 8, 2025 | B | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT HEAT RISER IN THE BATHROOM LOCATED AT APT 2R, 2nd... | 2R | Jun 12, 2025 |
| May 8, 2025 | B | NOV SENT OUT | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STOR... | 2R | Jun 12, 2025 |
| May 8, 2025 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 2R | Jun 12, 2025 |
| May 7, 2025 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | May 21, 2025 |