Skip to content

ECB violations

18-20 East Clarke Place, Bronx • Block 02839 • Lot 0014

39 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jun 4, 2025 39149914P ACTIVE CLASS - 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO... $1,280 $1,280 Jun 30, 2026
Aug 15, 2023 39092562X ACTIVE CLASS - 2 FOUND EXPOSE WIRES, BAROMETRIC DAMPER DEFECTIVE, BOILER DOORS MISSING BOLTS AND LATCHES AND NEED TO BE RESEALED, CORR... $655 $0 Jul 2, 2024
Oct 27, 2020 39031074H ACTIVE CLASS - 1 DOOR RESTRICTOR ALTERED (CEASE USE). MACHINE OIL LEAK. NO MIRROR IN CAB. PHONE MISSING. BRAKE MAINTENANCE TAG EXPIRED. $1,250 $0 Dec 18, 2020
Jun 17, 2020 38273562M ACTIVE CLASS - 1 42M07,02M07,12Q03,15M11,14M11 CLASS 1 ITEM.NO DOOR LOCK MONITORING & INSTALLED IN CONTROLLER AS MANDATED BY 3.10.12 O... $3,125 $0 Mar 12, 2021
Mar 7, 2020 39019171H RESOLVE CLASS - 1 CLASS 1, NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10. 12 OF APPENDIX K3 OF THE 2014 NYCB... $625 $0 Nov 20, 2020
Sep 26, 2018 38265481K RESOLVE CLASS - 1 CU05A10;69M07;59M07,56Y13,60Q03,39X10; 41T07,67M07,41I11,13B07,25M07;39O02,12Q03,42B09,26D07,42M07,53U07. 05A10-CEASE... $1,250 $0 Nov 30, 2018
Jul 24, 2018 38264392Y RESOLVE CLASS - 2 08I11,57M07,12M03,29L10,64M07,71X10,39O02,41M07,60M03,52M07,59M07,44M03,69M07,68B01. 08I11-RMDY: REPLACE SILL; 12M07-... $0 $0 Sep 7, 2018
Mar 21, 2017 38253498Z RESOLVE CLASS - 2 97X17 THE ONLY ELEVATOR IN BLDG OUT OF SERVICE.UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HA... $250 $0 May 5, 2017
May 6, 2015 38236205L RESOLVE CLASS - 2 05M07,16X10,39O02,41I11,41T07,56Y13,60X10,60Q03,67M07,69M07,71X10,71Q 03,77X10,77Q03,75I10,97X10. 05M07-PROVIDE CAR D... $0 $0 Jul 10, 2015
Jan 16, 2015 38233909X RESOLVE CLASS - 2 3D6,5J10,10H11,12Q7L,16H10,26D6,41I11. 3D6-RETURN POST WALL,UNSECURED;5J10-GAP BETWEN DOOR AND RETURN POST; 16H10-HOI... $0 $0 Mar 6, 2015
Apr 19, 2012 34925915Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG. NORTH ELEVATION, EXP #1 OBSERVE BLOCKS OF WOOD, BRICKS UNDER A/C UNITS; STORAGE ST... $250 $0 Jun 15, 2012
Jul 20, 2010 38211955J RESOLVE CLASS - 1 16M07,21M07.C/U(16M07)LOBBY HOISTWAY SWING DOOR IS MISSING,PROVIDE.C/U(21M07)LOBBY INTERLOCK IS MISSING,PROVIDE.BEFOR... $0 $0 Sep 17, 2010
Jul 12, 2010 36014075X RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... $1,000 $0 Nov 5, 2010
Jun 30, 2010 34857638N RESOLVE CLASS - 2 FAILED TO NOTIFY DEPT/OBTAIN PERMIT PRIOR TO USE/INST OF MATERIAL HOIST.MATERIAL HOIST ACTIVE @ EXP#3.REMEDY:NOTIFY T... $400 $0 Aug 26, 2010
Jun 30, 2010 34857637L RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS.1)OUTRIGGER SETUP ON A ANGLE.2)ANGLE... $250 $0 Aug 20, 2010
May 18, 2010 34837298H RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING.SOUTH ELEVATION(REAR)OBSERVE IRON GATE,LUMBER,STORAGE BLOCKING PATHWAY ON FIRE ... $500 $0 Jul 15, 2011
Jan 13, 2010 38207138H RESOLVE CLASS - 2 56Y10,58F10,21L10,16L10,16L10,08V10. 1621L-10-PULL ON 3RD FL HOISTWAY DOOR STOPS ELEVATOR IN FLIGHT 16L10-REPAIR 4TH ... $250 $0 Mar 5, 2010
Dec 23, 2009 34812033L ACTIVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C/O OR BLDG DEPT RECORDS. ATREAR OF PREMISES, SW CORNER OF BLDG, CELLAR LEV... $2,400 $0 Feb 19, 2010
Dec 23, 2009 34812035P RESOLVE CLASS - 1 WORK W/O A PERMIT.NOTED:@ CELLAR LEVEL OF PREMISES,FRONT OF BLDG ILLEGAL FULL HEIGHT PARTITIONS ERECTED CREATING A CL... $0 $0 Feb 22, 2010
Dec 23, 2009 34812034N RESOLVE CLASS - 1 WORK W/O A PERMIT.NOTED:AT CELLAR LEVELOF PREMISES ERECTED FULL HEIGHTPARTITIONS & CREATED A ROOM USED AS A CHURCH W/... $0 $0 Feb 22, 2010
Nov 27, 2009 36010437X RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... $800 $0 Feb 19, 2010
Oct 5, 2009 38206596K RESOLVE CLASS - 2 10H07/15M07/56Y13/56O02/58F10/60B07/ 10-H-07 CAR DOOR GIB ARE WORN PROVIDE.56-Y-13 SEAL OIL LEAK HOIST MACHINE.56-O-0... $250 $0 Feb 19, 2010
Apr 8, 2009 38202314P RESOLVE CLASS - 2 98U05.59F10.11X10.23X10.70O2.15M7.16L10.11.23.X10 ELEVATOR NOT RESPONDING TO 4TH FL CALL BUTTONS PROVIDE ACCESS TO 4 ... $500 $0 Jan 22, 2010
Feb 25, 2009 38201289H RESOLVE CLASS - 2 16J01.20M07.11X10.16A09.15M07.75I10. 16J01 ADJUST 2ND FL HATCH DOOR TO OPEN PROPERLY HANGING UP IN INTERLOCK 20M07 PR... $500 $0 Apr 17, 2009
Jan 30, 2009 36008182K RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... $800 $0 Jan 22, 2010
Jan 7, 2009 38199624X RESOLVE CLASS - 2 60B07, 56O02, 56Y13, 52H11. 60B07- PROVIDE LIGHTING IN MOTOR ROOM. 56O02- CLEAN OIL FROM MACHINE & BED PLATE. 56Y13- ... $500 $0 Jan 22, 2010
May 29, 2007 38167002P RESOLVE Non-Hazardous 21Q3/28Q3/57H10/59X11/12X11/14M7/18M7/63T15/69B10/32O2/33O2/35O2/38O2/39O2/66Z8/67O2/68O2/71O2/.12-TOP OF CAR. $180 $0 Aug 3, 2007
Jan 17, 2007 34545872Z RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL NOTED:AT FRONT FACADE OPEN CRACKS & MISSING MORTAR & BRICKS.REMEDY:MAINTAIN BL... $800 $0 Mar 2, 2007
Jul 27, 2006 34530457J RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL HAZARDOUS DEFECTS NOTED:NORTH WEST PARAPET HAS SUSTANTIAL CRACKS THRU OUT IS L... $800 $0 Jan 5, 2007
Oct 17, 2005 38149149K RESOLVE Non-Hazardous 84I10/84#10/15D6/66Z2 84) LOBBY FLOOR DAMAGED 2 IN GAP TO CAR 84) CAR COME INTO LAND VERY HARD. 15) MISSING GLASS COV... $180 $0 Feb 27, 2006
May 2, 2005 38152608H RESOLVE Non-Hazardous 14M10/16L10/21L10/15I10. 16-21-L-10 REPAIR EXESSIVE PLAY IN HATCH DOORAND LOCK ON 3RD FLOOR. 15I10- PROVIDE COVER $0 $0 Jun 17, 2005
Jan 3, 2005 34418052L RESOLVE Non-Hazardous FAILURE TO PROVIDE "IN CASE OF FIRE" ELEVATOR LANDINGS SIGNS ON ALL FLOORS. FAILURE TO PROVIDE 3" FLOOR NUMBERS ON AL... $0 $0 Feb 18, 2005
Feb 25, 2000 38093533P RESOLVE Non-Hazardous 57O02,57Z09,73X11,14M7,15K10,35P17,15K10,3002,26Q3,15E1,15L10. 73- RESTORE ELEVATOR TO SERVICE TO INSP BY D.O.B 18- R... $2,500 $0 Apr 14, 2000
Dec 9, 1998 38082451H RESOLVE Non-Hazardous 73X 35P 31Q 03B 53M 39H 30O 73 RESTORE DEVICE TO SERVICE 30 A FULL INSPECTION CAN BE MADE BY THEIS DEPT $440 $0 May 14, 1999
Oct 27, 1998 38079872Z RESOLVE Non-Hazardous 53M 39H 75U 37G 30I 31Q 03B 55L 57Z 57Z 73O 60M 14M 30O 62D 31 THROUGHOUT 03T OC LIGHT 60 CWT DUFFER MISSING CEASE US... $500 $0 Dec 14, 1998
Mar 26, 1996 38054450H RESOLVE Non-Hazardous 11M,14M,13M,57O,52#.52.ELEVATOR VERK WHEN IN MOTION ADJUST BREAKING AND/OR CURED PROBLEM SO DEVICE CLEAN RUN PROPERLY $200 $0 Aug 23, 1996
Jun 14, 1995 38050103P RESOLVE Non-Hazardous 73X,74O,35P. 73-RESTORE ELEV TO SERVICE. 35-ACCESS TO MOTOR ROOM. $1,000 $0 Apr 12, 1996
Jan 3, 1994 38039401X RESOLVE Non-Hazardous 35P,57O,73X, (35) PROVIDE ACCESS TO MOTOR ROOM (73) RESTORE ELEVATOR TO SERVICE $0 $0 Mar 11, 1994
Dec 10, 1990 38002919L RESOLVE Non-Hazardous 11Q,14M,11I,22W,20L,30O,40#. 40. 5YEAR TEST. $0 $0 Mar 28, 1991