ECB violations
East 171 Street, Bronx • Block 02844 • Lot 0065
144 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 14, 2026 | 39196031N | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSP... | $1,250 | $1,250 | Sep 18, 2026 |
| Mar 18, 2026 | 39180968X | RESOLVE | CLASS - 1 | OBSERVED AT THE 6TH-STORY HALLWAY IN THE EAST SECTION OF THE BUILDING, A WASHING UNIT AND TABLE ARE BEING STORED, CRE... | $2,500 | $2,500 | Jan 21, 2027 |
| Mar 18, 2026 | 39180969H | RESOLVE | CLASS - 2 | OBSERVED KEY-OPERATED LOCKS ARE INSTALLED ON DOORS PROVIDING ROOF ACCESS AND RE-ENTRY AT BOTH THE EAST AND WEST SECTI... | $0 | $0 | May 29, 2026 |
| Aug 21, 2025 | 39157996H | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSP... | $1,250 | $1,250 | Oct 31, 2025 |
| Jun 6, 2025 | 39150241H | ACTIVE | CLASS - 2 | PROVIDE CERTIFICATE OF COMPLIANCE. | $1,250 | $1,250 | Dec 5, 2025 |
| Jun 6, 2025 | 39150242J | ACTIVE | CLASS - 1 | RTS CLASS 1: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-9... | $1,250 | $1,250 | Dec 5, 2025 |
| Jan 31, 2025 | 39137093Z | RESOLVE | CLASS - 1 | OBSERVED AT EXPOSURE#2 PARAPET LEVEL , STEP CRACKS AND MORTAR MISSING IN BETWEEN BRICKS., REPAIR AND/REPLACE; REPAIR ... | $0 | $0 | Dec 8, 2025 |
| Dec 12, 2024 | 39132730J | RESOLVE | CLASS - 1 | : FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON IN... | $0 | $0 | Mar 17, 2026 |
| Nov 25, 2024 | 39131287J | RESOLVE | CLASS - 1 | RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION. THE DEVICE IS FOUND TO BE OUT-OF-SERVICE, AS PER 1RCNY 11-02... | $0 | $0 | Jul 25, 2025 |
| Jan 4, 2024 | 39102734J | RESOLVE | CLASS - 1 | UPON INSPECTION OBSERVED AT EXP.3/REAR COURTYARD HAS A LARGE WOODEN BOX BEING STORED DIRECTLY UNDERNEATH A FIRE ESCAP... | $312 | $0 | Aug 2, 2024 |
| Dec 4, 2023 | 39100660R | RESOLVE | CLASS - 1 | UPON MY INSPECTION FIND THE HAS NOT BEEN RESTORED TO SERVICE. CLASS 1 CONTINUED | $1,563 | $0 | Feb 16, 2024 |
| Jun 21, 2023 | 39088877Z | RESOLVE | CLASS - 1 | RESTORE TO SERVICE; ELEVATOR OUT OF SERVICE | $312 | $0 | Sep 1, 2023 |
| May 24, 2023 | 39087010L | RESOLVE | CLASS - 1 | RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION , THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING A HAZARDO... | $625 | $0 | Aug 4, 2023 |
| Mar 29, 2023 | 39082608N | RESOLVE | CLASS - 1 | ELEVATOR CURRENTLY OUT OF SERVICE IN THE LOBBY WITH DOORS CLOSED | $0 | $0 | Jun 2, 2023 |
| Jan 23, 2023 | 39078240M | RESOLVE | CLASS - 1 | RESPONDING ON A 311 ELEVATOR COMPLAINT, UPON INSPECTION OF DEVICE, VIOLATION , WAS FOUND, ITEMS; DOOR ZONE RESTRICTOR... | $0 | $0 | Aug 25, 2023 |
| Oct 26, 2021 | 39050053M | RESOLVE | CLASS - 2 | CLASS 2 VIOLATION ISSUED,/ CAR DOOR GIBBS MISSING, PROVIDE,/ NO ACCESS TO BASEMENT FLOOR,PROVIDE ACCESS,/ NO ACCESS I... | $312 | $0 | Mar 4, 2022 |
| Apr 28, 2021 | 39040307Y | RESOLVE | CLASS - 2 | NO RE-SHACKLE TAG ON CAR TOP, PROVIDE. MACHINE HAS OIL LEAK, CLEAN AND SEAL. | $312 | $0 | Jul 30, 2021 |
| Jan 7, 2021 | 39034468Y | RESOLVE | CLASS - 2 | PHONE INOPERATIVE, REPAIR. NO ACCESS TO PIT OR MACHINE ROOM. REMEDY; KEYS MUST BE ON SITE TO GAIN ACCESS IN THE EVENT... | $0 | $0 | Apr 16, 2021 |
| Mar 13, 2020 | 39019667L | RESOLVE | CLASS - 2 | BOILER FLOODED-NAME PLATE/MISSING, NOT AFFIXED TO BOILER-BODY DRAINS NOT INSTALLED ONTO SAFETY VALVES; CORRECT ALL VI... | $0 | $0 | Apr 23, 2021 |
| Mar 11, 2020 | 39019484Z | RESOLVE | CLASS - 1 | CEASE USE, 1/ ITEM, ALTERED CAR DOOR RESTRICTOR REMEDY; REPAIR AND CONTACT NYCDOB FOR RESTORE TO SERVICE RE INSPECTIO... | $1,250 | $0 | Sep 18, 2020 |
| Dec 4, 2019 | 35512930N | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39011324N ISSUED ON 10/17/19 & TO FILE A C OF C PURSUAN... | $0 | $0 | Feb 5, 2020 |
| Dec 4, 2019 | 35512931P | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39011325P ISSUED ON 10-17-19 & TO FILE A C OF C PURSUAN... | $0 | $0 | Feb 5, 2020 |
| Nov 13, 2019 | 38272288Y | RESOLVE | CLASS - 2 | 20M7,37D6,37R6,37B2,40M7,39B10,67X10,11M7,70M7:(20,M,7)VISION PANEL GLASS MISSING ON THE 2ND FL. (37,D,6)OVERHEAD DOO... | $312 | $0 | Jan 3, 2020 |
| Nov 13, 2019 | 38272289X | RESOLVE | CLASS - 2 | 11M7,20L10,37R7,40M7,67X10,70M7:(11,M,7)NO ACCESS TO THE BASEMENT FROMTHE CAR STATION. (20,L,10)LOBBY VISION GLASS BR... | $312 | $0 | Jan 3, 2020 |
| Oct 17, 2019 | 39011320X | RESOLVE | CLASS - 2 | NOTED: OBSERVED AT EXPOSURE 1 (EAST ELEVATION) OF 1455 WALTON AVENUE, DIAGONAL CRACKS AT THE CORNER OF ENTRANCE NEAR ... | $0 | $0 | Dec 6, 2019 |
| Oct 17, 2019 | 39011325P | RESOLVE | CLASS - 1 | NOTED: FULL HEIGHT PARTITIONS ERECTED AT NORTHEAST CORNER OF CELLAR TO CREATE LIVING QUARTERS FOR THE PORTER, WITH NO... | $0 | $0 | Dec 6, 2019 |
| Oct 17, 2019 | 39011329M | RESOLVE | CLASS - 1 | I OBSERVED IN THE CELLARS ELECTRICAL ROOM A 200 AMP SERVICE SWITCH THAT IS MISSING THE MAIN BONDING JUMPER BETWEEN TH... | $0 | $0 | Aug 13, 2021 |
| Oct 17, 2019 | 39011324N | RESOLVE | CLASS - 1 | NOTED: FULL HEIGHT PARTITIONS ERECTED AT NORTHEAST CORNER OF CELLAR TO CREATE LIVING QUARTERS FOR THE PORTER, WITH NO... | $0 | $0 | Dec 6, 2019 |
| Oct 17, 2019 | 35434241R | ACTIVE | CLASS - 1 | FUTURE CONNECTION EXIST DOWN STREAM FROM APPLIANCE.OBSERVED ON 10/17/19 AT THE ABOVE ADDRESS FUTURE GAS CONNECTION EX... | $2,500 | $0 | Feb 14, 2020 |
| Jan 16, 2019 | 38265068R | RESOLVE | CLASS - 1 | 16F1; 37I10, 37O2, 37D6,2X10,40M7. 16F1-ADJUST HOISTWAY DOORS SPPED DOORS CLOSING TOO HARD ALL FLOORS; 37I10-BROKEN O... | $1,250 | $0 | Jun 14, 2019 |
| Oct 18, 2018 | 38265945J | RESOLVE | CLASS - 2 | 10H11,32J01,40P16,67X10. DOOR GIBS ARE WORN REPLACE; 32J01-SHOES ALL ON CAR ARE MISALIGNED AND LOOSE ADJUST; 40P16-NO... | $0 | $0 | Dec 7, 2018 |
| Sep 26, 2018 | 38265756K | RESOLVE | CLASS - 1 | 37R7,37T7,40M7,67X10,97X10. 37R7-OVERHEAD ACCESS DOOR PINNED CLOSE; 37T7-OVERHEAD DOOR NOT LABELED; 40M7-NO ACCESS TO... | $1,250 | $0 | Nov 16, 2018 |
| Sep 26, 2018 | 38265755Z | RESOLVE | CLASS - 1 | 3.I.10,(C/U)5.A.7,11.B.7,32.B.10,(C/U)37.D.6,(C/U)37.R.9,40.M.7,67.X.10,70.M.7-(3,I,10)CAR STATION EMERGENCY LIGHT DA... | $1,250 | $0 | Nov 16, 2018 |
| May 22, 2018 | 32096899P | RESOLVE | CLASS - 2 | B254,50A,50B,50C,50D. AS PER CLASS 2 (B254) 28.301.1 FAILURE TO MAINTAIN 50A-COLD WATER PIPING TO BOILER COIL NOT SUP... | $310 | $0 | Jul 20, 2018 |
| May 15, 2018 | 35331958M | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ADEQUATE GROUNDING OF ELECTRICAL SYSTEMS. OBSERVED IN 600 AMP SERVICE SWITCH W/ 450 FUSE PROTECTIO... | $1,200 | $0 | Aug 10, 2018 |
| May 15, 2018 | 35331956Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS/ENCLOSURES/CABLE ARMOR. OBSERVED IN BASEMENT EL... | $600 | $0 | Aug 10, 2018 |
| May 15, 2018 | 35331962P | RESOLVE | CLASS - 2 | SEC: EC 300.15A. FAILURE TO PROVIDE TO ACCESS TO CONDUIT BODY COVER. OBSERVED IN BASEMENT ELEVATOR, MACHINE ROOM THE ... | $400 | $0 | Aug 10, 2018 |
| May 15, 2018 | 35331960L | RESOLVE | CLASS - 2 | FAILURE TO PROTECT CONDUCTORS AGAINST OVERCURRENT PER EC. OBSERVED IN BASEMENT SERVICE DISCONNECT FOR PUBLIC METER TH... | $1,200 | $0 | Aug 10, 2018 |
| May 15, 2018 | 35334314K | RESOLVE | CLASS - 2 | FAILURE TO SECURE/SUPPORT RACEWAYS/CABLE ASSEMBLIES/BOXES/CABINETS/FITTINGS. OBSERVE IN BASEMENT AREA AND ALONG EXTER... | $400 | $0 | Aug 3, 2018 |
| May 15, 2018 | 35329149J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: OBSERVED AT INNER ENTRANCE COURTYARD,LEFT(SOUTH)SIDE(1453 SID... | $620 | $0 | Jun 29, 2018 |
| May 15, 2018 | 35331961N | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE GROUND FAULT CIRCUIT INTERUPPTER (GFCI)PROTECTION. OBSERVED IN BASEMENT THE USE OF AN ELECTRIC WAS... | $1,200 | $0 | Aug 10, 2018 |
| May 15, 2018 | 35331963R | RESOLVE | CLASS - 2 | FAILURE TO PROPERLY CONNECT CONDUCTORS TO TERMINALS. OBSERVED IN ELEVATOR MOTOR ROOMS IN BASEMENT OF BLDG 1453 & 1455... | $600 | $0 | Aug 10, 2018 |
| May 15, 2018 | 35331957K | RESOLVE | CLASS - 2 | PROHIBITED USE OF ELECTRICAL METALLIC TUBING (EMT). OBSERVED ON EXTERIOR OF 1455 WALTON AVENUE THE USE OF EMT SUPPLYI... | $250 | $0 | Jun 29, 2018 |
| Apr 18, 2018 | 38262711N | RESOLVE | CLASS - 1 | CU5X10; 42N11,70O2,75I11,71X10,30M11,47Y13,29M11. 5X10-DOOR ZONE RE STRICTOR INOPERTIVE, REPAIR; 42N11-FUSES BYPASSED... | $1,250 | $0 | Jun 1, 2018 |
| Jan 18, 2018 | 38260292Z | RESOLVE | CLASS - 1 | CEASE USE 5X10, 65N10, 68B7, 52Y2, 44413, 39O2,70O2 5X10-DOOR RESTRICTOR IS INOPERATIVE,REPAIR .THIS DEVICE INSURES T... | $1,000 | $0 | Jun 22, 2018 |
| Aug 3, 2017 | 35284707Z | RESOLVE | CLASS - 1 | AN UNLAWFUL ACT. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT AND CERFIFY ECB #35253328R I... | $2,400 | $0 | Sep 29, 2017 |
| Jun 21, 2017 | 38255788X | RESOLVE | CLASS - 1 | 97X17 THE ONLY ELEVATOR IN BLDG(OR SECTION OF BLDG) OUT OF SERVICE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF ... | $1,000 | $0 | Aug 18, 2017 |
| Apr 25, 2017 | 35253330X | RESOLVE | CLASS - 1 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIALS APPARATUS,DEVICES,APPLIANCES OR WIRING IN USE. AT THE TIM... | $1,600 | $0 | Aug 11, 2017 |
| Apr 25, 2017 | 35253329Z | RESOLVE | CLASS - 1 | SEC. 503.5 INSTALLATION NOT CONFORM W/REQUIREMENTS FOR CLASSIFIED LOCATION. ATHE TIME OF MY INSPECTION I OBSERVED THE... | $1,600 | $0 | Aug 11, 2017 |
| Apr 25, 2017 | 35253328R | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. AT THE TIME OF MY INSPECTION I OBSERVED NEW CONDUIT & A SERVICE SWITCH FEEDING TO A GAS... | $1,600 | $0 | Aug 11, 2017 |