ECB violations
1710 Popham Avenue, Bronx • Block 02877 • Lot 0424
30 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 26, 2026 | 35729880L | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #1 WEST-CRACK... | $5,030 | $5,030 | Jul 31, 2026 |
| Feb 9, 2026 | 39176537M | ACTIVE | CLASS - 1 | 1) DOOR LOCK MONITORING IS NOT INSTALLED. 2) PHONE IS NOT WORKING. 3) THE GEAR CASE OIL NEEDS TO BE CHANGED (IT HAS T... | $12,500 | $12,500 | Apr 17, 2026 |
| May 9, 2024 | 39113983Y | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. CEASE USE ORDER IN EFFECT. CEASE USE ITEM: 1) PIT STOP SWITCH ... | $1,250 | $1,250 | Aug 5, 2025 |
| Mar 4, 2024 | 39107611M | RESOLVE | CLASS - 1 | DOOR LOCK MONITORING NOT INSTALLED AS MANDATED IN APPENDIX K 2014 BUILDING CODE. REMEDY: INSTALL DLM FILE AND PERFORM... | $0 | $0 | Feb 20, 2025 |
| Feb 23, 2024 | 39106739R | ACTIVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED IN APPENDIX K OF THE 2014 BUILDING CODE; REMEDY INSTALL D... | $3,125 | $3,125 | Jun 7, 2024 |
| Oct 30, 2023 | 39098239N | RESOLVE | CLASS - 1 | ENTIRE DEVICE IS SHUT DOWN. RETURN TO SERVICE AND RE-INSPECTION IS REQUIRED. | $1,250 | $1,250 | Mar 15, 2024 |
| Aug 15, 2023 | 39092531N | ACTIVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED IN APPENDIX K OF THE BUILDING CODES; REMEDY INSTALL DLM P... | $12,500 | $12,500 | Jul 2, 2024 |
| May 27, 2023 | 39087323M | RESOLVE | CLASS - 1 | RESPONDING TO A ELEVATOR 311 COMPLAINT, UPON ON INSPECTION OF DEVICE CLASS 1 VIOLATION ISSUED , 1/ RECURRING DLM NOT ... | $0 | $0 | Jul 18, 2024 |
| Nov 5, 2020 | 39031616N | ACTIVE | CLASS - 1 | CLASS 1 NO DLM INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 0F THE 2014 NYCBC REMEDY; FILE APPL... | $1,280 | $0 | Feb 19, 2021 |
| Jan 8, 2020 | 39015408Z | ACTIVE | CLASS - 1 | CLASS 1=NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC ... | $6,250 | $0 | Oct 30, 2020 |
| Jun 1, 2019 | 38270078R | RESOLVE | CLASS - 1 | CU45M07, 56Y10,42B11,43B10,42G09,59B07,64M07,71X10,78H14,16M07. CEASE USE ITEM; 45M-PROVIDE AND INSTALL AND RECALIBRA... | $1,280 | $0 | Jul 19, 2019 |
| Apr 25, 2019 | 38269423K | RESOLVE | CLASS - 2 | 16.I.10,(R/C)70.Z.09,26.D.06,42.B.09,98.B.07,59.B.07,(R/C)56.Y.13;(70)WATER LEAK ON PIT (26) PROPERTY SECURE (42) REM... | $0 | $0 | Jun 21, 2019 |
| Mar 9, 2019 | 38268752R | RESOLVE | CLASS - 1 | CU05A10,CU70Z09; 10H11,39O02,68B07. 05A10-CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/DISABLED AND RE... | $1,280 | $0 | May 3, 2019 |
| Oct 30, 2018 | 38265871X | RESOLVE | CLASS - 1 | R/C CU08V01; 25M07,77B06,34D06,70O02,52U07,52B10; R/C39O02,39D06,57BB11,59B07; R/C56Y13; 59D06,42M07. 08V01-C/U ITEM ... | $3,125 | $0 | Jan 11, 2019 |
| Oct 25, 2017 | 38258819N | RESOLVE | CLASS - 2 | 70Z02,71Q03,64M07,70M07,12M07,12Q03,56Y13,16H03,03I10,61M07,40S09-70)REMOVE WATER FROM PIT AND REPAIR SUB-PUMP. 71)PR... | $0 | $0 | Dec 15, 2017 |
| Jun 6, 2017 | 32088794Z | RESOLVE | CLASS - 3 | 36. AS PER CLASS 254-36 BURNER NOT REGISTER AS PER DOB RECORDS, CORRECT ALL VIOLATING CONDITION & SUBMIT A C OF C. | $0 | $0 | Aug 25, 2017 |
| Jan 10, 2017 | 38252406H | RESOLVE | CLASS - 2 | 08V01,32H11,34O02/(08)CAR NOT LEVEL ON LOBBY FLR AND 3RD FLOOR;(34)CLEAR ENTIRE SHAFTWAY. | $2,500 | $0 | Mar 3, 2017 |
| Dec 9, 2016 | 38251544L | RESOLVE | CLASS - 1 | 5M7,8V1,10H11,16J10/5M7;DOOR RESTRICTOR MISSING PROVIDE;8V1-CAR FLR TOLANDING SILL NOT LEVEL ADJUST;10H11-CAR DOOR GI... | $0 | $0 | Mar 24, 2017 |
| Sep 2, 2016 | 38246378Z | RESOLVE | CLASS - 1 | 05M7,10H11,8V1,16J10,56Y2,56Y13,40D6. DOOR RESTRICTOR MISSING PROVIDE CAR DOOR GIBS WORN REPLACE, CAR FLOOR TO LANDIN... | $1,000 | $0 | Apr 14, 2017 |
| Aug 3, 2016 | 38244343J | RESOLVE | CLASS - 2 | 31V01,32H10,70Z09,39O02. 31-LEVELING UNIT NOT LEVEL ADJUST; 32-GUIDESHOES WORN REPAIR; 70-PIT WATER LEAK REMOVE; 39-T... | $0 | $0 | Sep 30, 2016 |
| Jul 27, 2016 | 38244478R | RESOLVE | CLASS - 1 | CEASE USE. 08V01,70Z09,12I10,56Y13,39O02,05M07,32M07,16I10,20Q03,36Q03. (08)CAR EXCESSIVELY OFF LEVEL/ ADJUST. (70)RE... | $1,000 | $0 | Sep 16, 2016 |
| Mar 8, 2016 | 38241432H | RESOLVE | CLASS - 2 | 15M07,70O02. 15M07-PROVIDE CERTIFICATE FRAM; 70O02-CLEAN PIT. | $0 | $0 | Apr 29, 2016 |
| Feb 24, 2016 | 38241198Z | RESOLVE | CLASS - 2 | 05M07,57M15. 05M07-CAR DOOR RESTRICTOR MISSING (PROVIDE) | $0 | $0 | Apr 15, 2016 |
| Dec 10, 2014 | 38233994J | RESOLVE | CLASS - 2 | 35Q03,56Y13,58F10,67M07,71X10,77K11,81M07. 35Q03-INSTALL COVERS FOR ELECTRICAL BOXES IN SHAFTWAY; 58F10-REPAIR WORM A... | $250 | $0 | Jan 30, 2015 |
| Feb 1, 2008 | 38181417H | RESOLVE | Non-Hazardous | 15M11,34Q03,42Q03,51M07,66O02,66Z09,85BB05,86BB05.34Q03-INSTALL COVER FOR ELECTRICAL BOXES UNDER CAR.51M07-PROVIDE SP... | $180 | $0 | Apr 4, 2008 |
| Dec 6, 2005 | 34416735L | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ELEVATOR LANDING SIGN THAT SHALL READ. "IN CASE OF FIRE USE STAIRS, UNLESS OTHERWISE INSTRUCTED" A... | $0 | -$200 | Mar 17, 2006 |
| Feb 29, 2000 | 38094927M | RESOLVE | Non-Hazardous | 08V01,50Y11,50F11,47K12,62Q03,31Q03. 47- RUSTED AND WORN 62- EXPOSED WIRES 31- PIT INTERLOCK SHAFT COVER | $2,500 | $0 | Apr 14, 2000 |
| Mar 3, 1998 | 38071135M | RESOLVE | Non-Hazardous | 75U,17I,15T,50Y,50O,73U,10M,73O,20B,15K,15M,57O,31D,32Q,17I-REPLACE CAB DOOR GLASS 15K-4 FL HALL DOOR. | $180 | $0 | Sep 28, 1998 |
| Feb 28, 1992 | 38021746X | RESOLVE | Non-Hazardous | 73X, RESTORE ELEV. TO SERVICE 50 AN INSP. CAN BE MADE. | $150 | $0 | Jan 14, 1993 |
| Feb 21, 1992 | 38021222P | RESOLVE | Non-Hazardous | 73X, 73. RESTORE ELEVATOR SERVICE SO PROPER INSPECTION CAN BE MADE BY THIS DEPARTMENT | $1,000 | $0 | Apr 24, 1992 |